Xianlin Zheng

Xianlin Zheng

Auto-generated profile, based on publicly available information

Xianlin Zheng

Advanced Cytometry Laboratories, ARC Centre of Excellence for Nanoscale BioPhotonics (CNBP), Macquarie University , Sydney, New South Wales 2109, Australia

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2017 in Nature
Verified
Journal Article
Closed access
YLYujia Liu
Yujia Liu
YLYiqing Lu
Yiqing Lu
Xusan YangXusan Yang
Xusan Yang
XZXianlin Zheng
Xianlin Zheng
Shihui WenShihui Wen
Shihui Wen
DJDayong Jin
Dayong Jin

6 August 2018 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
YFYong Fan
Yong Fan
PWPeiyuan Wang
Peiyuan Wang
YLYiqing Lu
Yiqing Lu
RWRui Wang
Rui Wang
LZLei Zhou
Lei Zhou
FZFan Zhang
Fan Zhang

8 March 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
XZXianlin Zheng
Xianlin Zheng
XZXingjun Zhu
Xingjun Zhu
YLYiqing Lu
Yiqing Lu
JZJiangbo ZHAO
Jiangbo ZHAO
WFWei Feng
Wei Feng
DJDayong Jin
Dayong Jin

30 May 2016 in Advanced Optical Materials
Verified
Journal Article
Closed access
PDF file
JZJiangbo ZHAO
Jiangbo ZHAO
XZXianlin Zheng
Xianlin Zheng
Erik SchartnerErik Schartner
Erik Schartner
PIPaul Ionescu
Paul Ionescu
Run ZhangRun Zhang
Run Zhang
HEHeike Ebendorff-Heidepriem
Heike Ebendorff-Heidepriem

16 August 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
DDDenitza Denkova
Denitza Denkova
MPMartin Ploschner
Martin Ploschner
MDMinakshi Das
Minakshi Das
LPLindsay Parker
Lindsay Parker
XZXianlin Zheng
Xianlin Zheng
JPJim Piper
Jim Piper
Sub-diffraction microscopy enables bio-imaging with unprecedented clarity. However, most super-resolution methods require complex, costly purpose-built systems, involve image post-processing and struggle with sub-diffraction imaging in 3D. Here, we realize a conceptually different super-resolution approach which circumvents these limitations and enables 3D sub-diffraction imaging on conventional confocal microscopes. We refer to it as super-linear excitation-emission (SEE) microscopy, as it relies on markers with super-linear dependence of the emission on the excitation power. Super-linear markers proposed here are upconversion nanoparticles of NaYF4, doped with 20% Yb and unconventionally high 8% Tm, which are conveniently excited in the near-infrared biological window. We develop a computational framework calculating the 3D resolution for any viable scanning beam shape and excitation-emission probe profile. Imaging of colominic acid-coated upconversion nanoparticles endocytosed by neuronal cells, at resolutions twice better than the diffraction limit both in lateral and axial directions, illustrates the applicability of SEE microscopy for sub-cellular biology.

13 October 2014 in Scientific Reports
Verified
Journal Article
Open access
LZLixin Zhang
Lixin Zhang
XZXianlin Zheng
Xianlin Zheng
WDWei Deng
Wei Deng
YLYiqing Lu
Yiqing Lu
SLSeverine Lechevallier
Severine Lechevallier
DJDayong Jin
Dayong Jin
Time-gated luminescence microscopy using long-lifetime molecular probes can effectively eliminate autofluorescence to enable high contrast imaging. Here we investigate a new strategy of time-gated imaging for simultaneous visualisation of multiple species of microorganisms stained with long-lived complexes under low-background conditions. This is realized by imaging two pathogenic organisms (Giardia lamblia stained with a red europium probe and Cryptosporidium parvum with a green terbium probe) at UV wavelengths (320–400 nm) through synchronization of a flash lamp with high repetition rate (1 kHz) to a robust time-gating detection unit. This approach provides four times enhancement in signal-to-background ratio over non-time-gated imaging, while the average signal intensity also increases six-fold compared with that under UV LED excitation. The high sensitivity is further confirmed by imaging the single europium-doped Y2O2S nanocrystals (150 nm). We report technical details regarding the time-gating detection unit and demonstrate its compatibility with commercial epi-fluorescence microscopes, providing a valuable and convenient addition to standard laboratory equipment.