1 November 2021 in Journal of Pediatric Surgery
19 October 2023 in IEEE Transactions on Instrumentation and Measurement
The present work focuses on designing a pin-on-disc tribometer used to perform dry or lubricated wear tests according to the ASTM G99 standard method. The pin-on-disc device was developed using the engineering design process (EDP) based on steps related to problem understanding and solution construction stages. The tribometer is composed of an aluminum structure, a cylindrical test chamber, a disk rotation control system, load cells for measuring normal and tangential forces, a disk position sensor and temperature sensors. A 7” touch screen was selected for the user interface (HMI). Wear tests to verify the reliability and usefulness of the tribometer were carried out on disc-samples extracted from a hot-rolled AISI 1025 carbon-steel commercial bar, and performed with 2 and 10 N normal loads, linear sliding speeds of 0.27, 0.54, 0.82, 1.10 and 1.63 m/s, 500 m total sliding distance, using alumina ball as counterbody material. Dry and lubricated conditions were considered. Parameters as sliding distance, normal and frictional forces, and coefficient of friction were monitored during real-time tests. The procedure proved to be simple and safe. HMI enables the user to configure easily and quickly the test condition. A good agreement between the duplicate results was observed. During calibration, it was observed that the load cells and the servomotor presented standard deviations lower than 1.1 g and 0.2 rpm, respectively, and a percentage of uncertainty lower than 0.3. The LVDT showed a correlation regression coefficient of 0.999 between measured and output signals. During wear validation tests, all variations in results were less than 2% under the investigated conditions.
22 December 2022 in Human Factors: The Journal of the Human Factors and Ergonomics Society
Objective: We explore the relationships between objective communication patterns displayed during virtual team meetings and established, qualitative measures of team member effectiveness. Background: A key component of teamwork is communication. Automated measures of objective communication patterns are becoming more feasible and offer the ability to measure and monitor communication in a scalable, consistent and continuous manner. However, their validity in reflecting meaningful measures of teamwork processes are not well established, especially in real-world settings. Method: We studied real-world virtual student teams working on semester-long projects. We captured virtual team meetings using the Zoom video conferencing platform throughout the semester and periodic surveys comprising peer ratings of team member effectiveness. Leveraging audio transcripts, we examined relationships between objective measures of speaking time, silence gap duration and vocal turn-taking and peer ratings of team member effectiveness. Results: Speaking time, speaking turn count, degree centrality and (marginally) speaking turn duration, but not silence gap duration, were positively related to individual-level team member effectiveness. Time in dyadic interactions and interaction count, but not interaction length, were positively related to dyad-level team member effectiveness. Conclusion: Our study highlights the relevance of objective measures of speaking time and vocal turn-taking to team member effectiveness in virtual project-based teams, supporting the validity of these objective measures and their use in future research. Application: Our approach offers a scalable, easy-to-use method for measuring communication patterns and team member effectiveness in virtual teams and opens the opportunity to study these patterns in a more continuous and dynamic manner.
1 July 2011 in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
During physiological spontaneous breathing maneuvers, the diaphragm displaces volume while maintaining curvature. However, with maximal diaphragm activation, curvature decreases sharply. We tested the hypotheses that the relationship between diaphragm muscle shortening and volume displacement (VD) is nonlinear and that curvature is a determinant of such a relationship. Radiopaque markers were surgically placed on three neighboring muscle fibers in the midcostal region of the diaphragm in six dogs. The three-dimensional locations were determined using biplanar fluoroscopy and diaphragm VD, curvature, and muscle shortening were computed in the prone and supine postures during spontaneous breathing (SB), spontaneous inspiration efforts after airway occlusion at lung volumes ranging from functional residual capacity (FRC) to total lung capacity, and during bilateral maximal phrenic nerve stimulation at those same lung volumes. In supine dogs, diaphragm VD was approximately two- to three-fold greater during maximal phrenic nerve stimulation than during SB. The contribution of muscle shortening to VD nonlinearly increases with level of diaphragm activation independent of posture. During submaximal diaphragm activation, the contribution is essentially linear due to constancy of diaphragm curvature in both the prone and supine posture. However, the sudden loss of curvature during maximal bilateral phrenic nerve stimulation at muscle shortening values greater than 40% (ΔL/LFRC) causes a nonlinear increase in the contribution of muscle shortening to diaphragm VD, which is concomitant with a nonlinear change in diaphragm curvature. We conclude that the nonlinear relationship between diaphragm muscle shortening and its VD is, in part, due to a loss of its curvature at extreme muscle shortening.
1 December 2001 in European Journal of Oral Sciences
1 March 2017 in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Muscle shortening and volume displacement (VD) are critical determinants of the pressure-generating capacity of the diaphragm. The present study was designed to test the hypothesis that diaphragm VD is heterogeneous and that distribution of VD is dependent on regional muscle shortening, posture, and the level of muscle activation. Radioopaque markers were sutured along muscle bundles of the peritoneal surface of the crural, dorsal costal, midcostal, and ventral costal regions of the left hemidiaphragm in four dogs. The markers were followed by biplanar video fluoroscopy during quiet spontaneous breathing, passive inflation to total lung capacity (TLC), and inspiratory efforts against an occluded airway at three lung volumes spanning the vital capacity [functional residual capacity, functional residual capacity + ½ inspiratory capacity, and TLC in both the prone and supine postures]. Our data show the ventral costal diaphragm had the largest VD and contributed nearly two times to the total diaphragm VD compared with the dorsal costal portion. In addition, the ventral costal diaphragm contributed nearly half of the total VD in the prone position, whereas it only contributed a quarter of the total VD in the supine postition. During efforts against an occluded airway and during passive inflation to TLC in the supine position, the crural diaphragm displaced volume equivalent to that of the midcostal portion. Regional muscle shortening closely matched regional VD. We conclude that the primary force generator of the diaphragm is primarily dominated by the contribution of the ventral costal region to its VD.