23 March 2013 in International Orthopaedics
1 May 2007 in Annals of Surgery
To investigate muscularis inflammation and endogenous endotoxin as causes of postoperative ileus. Postoperative inflammatory ileus of the colon is associated with a significant delay in gastrointestinal transit. We investigated whether these changes are caused by the downstream obstructive barrier of the surgically altered colon or by small intestinal muscularis inflammation itself. Furthermore, we evaluated the mechanistic role of gut derived endotoxin in the development of postoperative intestinal dysfunction. Rats underwent surgical manipulation of the colon. Isolated gastrointestinal transit was analyzed in animals with ileostomy. The perioperative emigration of intracolonic particles was investigated by colonic luminal injection of fluorescently labeled LPS and microspheres. Mediator mRNA induction was quantified by real-time RT-PCR. Muscularis leukocytic infiltrates were characterized. In vitro circular muscle contractility was assessed in a standard organ bath. Ileostomy rats presented with a significant delay in small intestinal transit after colonic manipulation. This was associated with leukocyte recruitment and inflammatory mediator mRNA induction within the small intestinal muscularis. Colonic manipulation caused the transference of intracolonic LPS and microspheres into the intestinal muscularis. Postoperative in vitro small intestinal circular muscle contractility was impaired by 42% compared with controls. Gut decontamination and TLR-4 deletion significantly alleviated the small intestinal muscularis inflammation and prevented intestinal muscle dysfunction. Selective colonic manipulation initiates a distant inflammatory response in the small intestinal muscularis that contributes to postoperative ileus. The data provide evidence that gut-derived bacterial products are mechanistically involved in the initiation of this remote inflammatory cascade.
28 October 2008 in International Orthopaedics
Femoral malrotation in total knee arthroplasty causes flexion gap instability. Conventional instruments mostly reference the posterior condylar angle (PCA). The aim of this study was to verify whether the computer-navigated flexion gap (GAP) method produces a rectangular flexion gap and if a balanced flexion gap could also be achieved by referencing the PCA. A total of 100 knee prostheses were analysed using the navigated GAP method, and flexion gap symmetry along with femoral rotation were recorded. The GAP technique resulted in a rectangular flexion gap with adequate femoral rotational alignment. If the PCA technique had been used, only 51% of the femoral components would have been implanted in correct femoral rotation; the remaining 49% would have implanted with flexion gap instability. The GAP technique produces a rectangular flexion gap. The referencing of the PCA was shown to be less reliable. Thus, modern knee prosthesis instrumentation should not base femoral rotation solely on the PCA.
1 February 2017 in The Journal of Arthroplasty
13 July 2010 in Orthopedics
The blood loss that accompanies total knee arthroplasty (TKA) can be substantial. Many patients need perioperative blood transfusions. To avoid anemia and transfusion-related complications, the amount of blood loss and need for blood transfusions must be reduced. If standard jig instruments are used, an opening of the femoral medullary canal is required. This operative step has been recognized as a reason for elevated blood loss; it is not required if computer navigation is used. Hence, the purpose of this study was to investigate the effect of computer navigation on blood loss and transfusion rate in TKA. The data of 500 consecutive patients undergoing TKA were analyzed, and patient- and operation-related data and blood loss and transfusion rates were recorded. The total blood loss was calculated by use of the Orthopedic Surgery Transfusion Hemoglobin European Overview (OSTHEO) formula. The average blood loss in the drainages (standard procedures, 880 mL; navigated procedures, 761 mL; P =.001) and the calculated total blood loss (standard procedures, 1375 mL; navigated procedures, 1242 mL; P =.036) were significantly reduced in the navigation group. The transfusion rate of navigated procedures was almost halved (standard procedures, 0.23 transfusions/patient; navigated procedures, 0.12 transfusions/patient; P =.035). Our study demonstrated a reduced blood loss if TKAs were implanted by use of computer navigation. The diminished blood loss resulted in a 50% reduction of allogenic blood transfusions. Hence, computer navigation may be attractive for patients with a high risk of transfusions or uncommon blood groups. Prospective studies are required to verify this potential benefit of computer navigation.
1 October 2010 in Neurogastroenterology & Motility