Arkadiusz Bula

Arkadiusz Bula

Auto-generated profile, based on publicly available information

Arkadiusz Bula

Jacobs Engineering Group Inc., M. Konopnickiej 31 St., 30-302 Krakow, Poland

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Architecture, Civil Engineering, Environment
Verified
Journal Article
Open access
PDF file
MKMarcin Kozłowski
Marcin Kozłowski
ABArkadiusz Bula
Arkadiusz Bula
JHJacek Hulimka
Jacek Hulimka
Experimental testing of epoxy adhesives, which are commonly used in civil engineering for the strengthening of existing structures with composite products have been a topic of limited studies. It was due to the damage which usually occurred not in the adhesive layer but in the strengthened material. Recent studies have shown that the choice of an adhesive significantly affects the load-bearing capacity of the entire joint. The paper presents the results of strength tests of a selected methyl methacrylate adhesive, carried out according to the standards EN ISO 527-1 and EN ISO 527-2. Comparing the results to the data provided by the manufacturer (tested in accordance with ASTM D638) discrepancies have been found in the normative assumptions and consequently differences in the results. Experiments on the adhesive showed clear dependency on the speed of testing which revealed through variable characteristics after the elastic limit. Numerical simulations were also carried out assuming the elastic-plastic material model. The analyses allowed to obtain the distribution of stresses and deformations along the length of the sample and allowed to verify the length of the extensometer used. Comparison of results obtained for different measuring lengths of chosen adhesive confirmed the need to use extensometers in the testing of mechanical properties.

3 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Marta KałużaMarta Kałuża
Marta Kałuża
JHJacek Hulimka
Jacek Hulimka
ABArkadiusz Bula
Arkadiusz Bula
The use of adhesive to joint structural elements, despite many advantages of this technology, is not a method commonly used in engineering practice, especially in construction. This is mainly due to the poor recognition of the behavior, both in terms of testing and analysis, of joints made on a scale similar to the actual elements of building structures. Therefore, this paper presents the results of model tests and then numerical analyses of adhesively bonded joints made of high-strength steel elements in a full-scale (double-lap joint). In order to properly model the adhesive connection, material tests of the methacrylate adhesive were performed in the field of tensile, shear (in two versions: single lap joint test and thick adherent shear test) and bond properties. Comparison of the results of the model and numerical tests showed very good agreement in terms of the measurable values, which makes it possible to consider the results obtained in the adhesive layer as reliable (not directly measurable in model tests). In particular, the distribution of stresses inside the adhesive layer, the range of plastic zones and areas of loss of adhesion are presented and discussed. The results indicate the possibility of a reliable representation of the behavior of adhesively bonded joints of high-strength steel, thus providing a tool for the analysis of semirigid adhesive in large-size joints.

22 January 2019 in International Journal of Polymer Analysis and Characterization
Verified
Journal Article
Closed access
ABArkadiusz Bula
Arkadiusz Bula
SJSebastian Jurczyk
Sebastian Jurczyk
BCBłażej Chmielnicki
Błażej Chmielnicki
JHJacek Hulimka
Jacek Hulimka
Marcin KozłowskiMarcin Kozłowski
Marcin Kozłowski
The paper presents the results of Dynamic-Mechanical Thermal Analysis (DMTA) for a selected methacrylate adhesive at the frequency range from 1 to 50 Hz and the heating rate of 1 and 3 °C/min, in the range from –70 °C to 180 °C. On the basis of the test results, the glass transition temperature was evaluated for three calculation methods. Master curves were also designated for three different reference temperatures: –20, +20 and +60 °C. Master curves were calculated using shift factors aT - calculated by numerical method.