Heng Li

Heng Li

Auto-generated profile, based on publicly available information

Heng Li

Tsinghua‐Berkeley Shenzhen Institute (TBSI) Tsinghua University Shenzhen 518055 China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2022 in Nanophotonics
Verified
Journal Article
Open access
PDF file
DCDanni Chen
Danni Chen
HLHeng Li
Heng Li
BYBin Yu
Bin Yu
Junle QuJunle Qu
Junle Qu
Research on dynamic events in living cells, such as intracellular transportation, is important for understanding cell functions. As movements occur within cells, the microenvironment of the moving vesicles or biomacromolecules may affect the behavior of them. Herein, we propose a method of simultaneously monitoring changes in spatial positions and the local environment related to the fluorescence lifetime, i.e., four‐dimensional (4D) multi‐particle parallel‐tracking in living cells. Based on double‐helix point spread function (DH‐PSF) microscopy and streak camera, the method combines three‐dimensional (3D) localization methods and fluorescence lifetime imaging. By modifying the PSF of the system, the 3D positions and fluorescence lifetime information for several molecules within a depth of a few microns can be acquired simultaneously from a single snapshot. The feasibility of this method is verified by simulating the real‐time tracking of a single particle with a given trajectory. In addition, a proof‐of‐concept 4D tracking system based on the DH‐PSF and streak camera was built. The experimental results show that the 3D localization and lifetime precision are σ ( x , y , z ) = (26 nm, 35 nm, 53 nm) and σ ( τ ) = 103 ps, respectively, and the effective depth of field is approximately 4 μm. Finally, intracellular endocytosis in a living cell was observed using the system, which demonstrated the successful 4D tracking of two microspheres moving within an axial depth of 4 μm. This work opens a new perspective for research of dynamic processes, by providing information about the chemical (microenvironments) and physical (positions) changes of moving targets in living cells.

15 February 2023 in Journal of Innovative Optical Health Sciences
Verified
Journal Article
Open access
PDF file
HHHaixin Huang
Haixin Huang
HQHaoyuan Qiu
Haoyuan Qiu
HWHanzhe Wu
Hanzhe Wu
YJYihong Ji
Yihong Ji
HLHeng Li
Heng Li
Junle QuJunle Qu
Junle Qu
Fourier light-field microscopy (FLFM) uses a microlens array (MLA) to segment the Fourier plane of the microscopic objective lens to generate multiple two-dimensional perspective views, thereby reconstructing the three-dimensional (3D) structure of the sample using 3D deconvolution calculation without scanning. However, the resolution of FLFM is still limited by diffraction, and furthermore, it is dependent on the aperture division. In order to improve its resolution, a super-resolution optical fluctuation Fourier light-field microscopy (SOFFLFM) was proposed here, in which the super-resolution optical fluctuation imaging (SOFI) with the ability of super-resolution was introduced into FLFM. SOFFLFM uses higher-order cumulants statistical analysis on an image sequence collected by FLFM, and then carries out 3D deconvolution calculation to reconstruct the 3D structure of the sample. The theoretical basis of SOFFLFM on improving resolution was explained and then verified with the simulations. Simulation results demonstrated that SOFFLFM improved the lateral and axial resolution by more than [ ] and 2 times in the second- and fourth-order accumulations, compared with that of FLFM.

16 November 2021 in Nanophotonics
Verified
Journal Article
Open access
PDF file
JNJielei Ni
Jielei Ni
BCBo Cao
Bo Cao
GNGang Nui
Gang Nui
DCDanni Chen
Danni Chen
GLGuotao Liang
Guotao Liang
YNyanxiang ni
yanxiang ni
Single‐molecule localization microscopy (SMLM) plays an irreplaceable role in biological studies, in which nanometer‐sized biomolecules are hardly to be resolved due to diffraction limit unless being stochastically activated and accurately located by SMLM. For biological samples preimmobilized for SMLM, most biomolecules are cross‐linked and constrained at their immobilizing sites but still expected to undergo confined stochastic motion in regard to their nanometer sizes. However, few lines of direct evidence have been reported about the detectability and influence of confined biomolecule stochastic motion on localization precision in SMLM. Here, we access the potential stochastic motion for each immobilized single biomolecule by calculating the displacements between any two of its localizations at different frames during sequential imaging of Alexa Fluor‐647‐conjugated oligonucleotides. For most molecules, localization displacements are remarkably larger at random frame intervals than at shortest intervals even after sample drift correction, increase with interval times and then saturate, showing that biomolecule stochastic motion is detected and confined around the immobilizing sizes in SMLM. Moreover, localization precision is inversely proportional to confined biomolecule stochastic motion, whereas it can be deteriorated or improved by enlarging the biomolecules or adding a post‐crosslinking step, respectively. Consistently, post‐crosslinking of cell samples sparsely stained for tubulin proteins results in a better localization precision. Overall, this study reveals that confined stochastic motion of immobilized biomolecules worsens localization precision in SMLM, and improved localization precision can be achieved via restricting such a motion.

13 February 2025 in Nanophotonics
Verified
Journal Article
Open access
PDF file
HWHanzhe Wu
Hanzhe Wu
DCDanni Chen
Danni Chen
YJYihong Ji
Yihong Ji
GXGan Xiang
Gan Xiang
YNyanxiang ni
yanxiang ni
JQJunle Qu
Junle Qu
Among the approaches in three‐dimensional (3D) single molecule localization microscopy, there are several point spread function (PSF) engineering approaches, in which depth information of molecules is encoded in 2D images. Usually, the molecules are excited sparsely in each raw image. The consequence is that the temporal resolution has to be sacrificed. In order to improve temporal resolution and ensure localization accuracy, we propose a method, SH‐CS, based on light needle excitation, detection system with single helix‐point spread function (SH‐PSF), and compressed sensing (CS). Although the SH‐CS method still has a limitation about the molecule density, it is suited for relatively dense molecules. For each light needle scanning position, an SH image of excited molecules is processed with CS algorithm to decode their axial information. Simulations demonstrated, for random distributed 1–15 molecules in depth range of 4 μm, the axial localization accuracy is 12.1–73.5 nm. The feasibility of this method is validated with a designed 3D sample composed of fluorescent beads.

26 August 2022 in arXiv
Verified
Preprint
Open access
PDF file
HHHaixin Huang
Haixin Huang
HQHaoyuan Qiu
Haoyuan Qiu
HWHanzhe Wu
Hanzhe Wu
YJYihong Ji
Yihong Ji
HLHeng Li
Heng Li
Junle QuJunle Qu
Junle Qu
Fourier light-field microscopy (FLFM) uses a micro-lens array (MLA) to segment the Fourier Plane of the microscopic objective lens to generate multiple two-dimensional perspective views, thereby reconstructing the three-dimensional(3D) structure of the sample using 3D deconvolution calculation without scanning. However, the resolution of FLFM is still limited by diffraction, and furthermore, dependent on the aperture division. In order to improve its resolution, a Super-resolution optical fluctuation Fourier light field microscopy (SOFFLFM) was proposed here, in which the Sofi method with ability of super-resolution was introduced into FLFM. SOFFLFM uses higher-order cumulants statistical analysis on an image sequence collected by FLFM, and then carries out 3D deconvolution calculation to reconstruct the 3D structure of the sample. Theoretical basis of SOFFLFM on improving resolution was explained and then verified with simulations. Simulation results demonstrated that SOFFLFM improved lateral and axial resolution by more than sqrt(2) and 2 times in the 2nd and 4th order accumulations, compared with that of FLFM.