Ziyu Wang

Ziyu Wang

Auto-generated profile, based on publicly available information

Ziyu Wang

College of Medical and Biological lnformation Engineering, Northeastern University, Shenyang 110170, China

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2023 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
YZYan Zu
Yan Zu
ZWZiyu Wang
Ziyu Wang
HYHuiqin Yao
Huiqin Yao
Liang YANLiang YAN
Liang YAN
Radiotherapy (RT), the most commonly used treatment method in clinics, shows unique advantages such as strong penetration, high energy intensity, and low systemic side effects. However, in vivo tumor hypoxia seriously hinders the therapeutic effect of RT. Hypoxia is a common characteristic of locally advanced solid tumor microenvironments, which leads to the proliferation, invasion and metastasis of tumor cells. In addition, oxygen consumption during RT will further aggravate tumor hypoxia, causing a variety of adverse side effects. In recent years, various biocatalytic nanomaterials (BCNs) have been explored to regulate and reverse tumor hypoxia microenvironments during RT. In this review, the most recent efforts toward developing oxygen-generating BCNs in relieving tumor hypoxia in RT are focused upon. The classification, engineering nanocatalytical activity of oxygen-generating BCNs and combined therapy based on these BCNs are systematically introduced and discussed. The challenges and prospects of these oxygen-generating BCNs in RT applications are also summarized.

1 April 2021 in Cancer Management and Research
Verified
Journal Article
Open access
PDF file
TZTianxiang Zhang
Tianxiang Zhang
WLWei Li
Wei Li
MGMeng Gu
Meng Gu
ZWZiyu Wang
Ziyu Wang
SZShijie Zhou
Shijie Zhou
SXShaofa Xu
Shaofa Xu
Purpose: Accumulating evidence has indicated that dysregulated microRNAs (miRNAs) are involved in cancer progression. In this study, we evaluated the clinicopathologic significance of miR-183-3p and miR-182-5p, and the role of miR-183-3p in non-small-cell lung cancer (NSCLC) progression. Patients and Methods: Seventy-six NSCLC patients from Beijing Chest Hospital were included. The expression of miR-183-3p and miR-182-5p was evaluated by real-time quantitative polymerase chain reaction (RT-qPCR). Then, cell growth curve assays and colony formation assays were performed. Bioinformatics analysis of TCGA database was performed to explore the clinicopathological significance and prognostic value. Results: miR-183-3p and miR-182-5p were significantly increased in NSCLC tumor tissues (both P < 0.0001) and were positively correlated (r = 0.8519, P < 0.0001). miR-183-3p (P = 0.0444) and miR-182-5p (P = 0.0132) were correlated with tumor size. In addition, miR-183-3p (P = 0.0135) and miR-182-5p (P = 0.0009) were upregulated in normal lung tissues from smokers. In vitro, miR-183-3p was correlated with cell proliferation. In addition, bioinformatics analysis indicated that miR-183-3p was correlated with poor prognosis (P = 0.0466) and tumor size (P = 0.0017). In addition, miR-183-3p was higher in lung squamous carcinoma (LUSC) tissue (P < 0.0001) than in lung adenocarcinoma (LUAD) tissue, and miR-183-3p was higher in the tumor tissue of smokers (P = 0.0053) than in that of nonsmokers. Conclusion: Upregulation of miR-183-3p and miR-182-5p may play an oncogenic role in NSCLC. miR-183-3p could be used as a potential prognostic biomarker and therapeutic target to manage lung cancer.

1 January 2010
Verified
Conference Paper
Closed access
JOJonathon Oiler
Jonathon Oiler
XQXiaotun Qiu
Xiaotun Qiu
JZJie Zhu
Jie Zhu
ZWZiyu Wang
Ziyu Wang
CYCunjiang Yu
Cunjiang Yu
HYHongyu YU
Hongyu YU
This paper describes a high-energy electromagnetic wave radiation detection device using zinc oxide (ZnO) based Film Bulk Acoustic-Wave Resonator (FBAR). The resonant frequency of the FBAR decreased after gamma radiation, with the peak sensitivity of 9.3 kHz/krad and minimum detectable dosage of 218 rad occurring at the lowest experimental dose of 20 krad (all dosages are calibrated with ZnO), while the sensitivity decreased with increasing total ionizing dosage. The incident radiation generated charges that was trapped near the ZnO-silicon nitride (SiN) interface, which increased the plate capacitance of the FBAR, resulting in the decrease of resonant frequency.