Hua Li

Hua Li

Auto-generated profile, based on publicly available information

Hua Li

University of Illinois Urbana-Champaign, Department of Bioengineering, Urbana, Illinois, United States

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
AAAmine Amyar
Amine Amyar
RMRomain Modzelewski
Romain Modzelewski
HLHua Li
Hua Li
Ruan SuRuan Su
Ruan Su

24 January 2019 in Medical Physics
Verified
Journal Article
Open access
PDF file
BCBin Cai
Bin Cai
ELEric Laugeman
Eric Laugeman
TMThomas R. Mazur
Thomas R. Mazur
JPJustin C. Park
Justin C. Park
LHLauren E. Henke
Lauren E. Henke
HLHua Li
Hua Li
Purpose: This study aims to characterize the performance of a prototype rapid kilovoltage (kV) x‐ray image guidance system onboard the newly released Halcyon 2.0 linear accelerator (Varian Medical Systems, Palo Alto, CA) by use of conventional and innovatively designed testing procedures.Methods: Basic imaging system performance tests and radiation dose measurements were performed for all eleven kV‐cone beam computed tomography (CBCT) imaging protocols available on a preclinical Halcyon 2.0 LINAC. Both conventional CBCT reconstruction using the Feldkamp–Davis–Kress (FDK) algorithm and a novel, advanced iterative reconstruction (iCBCT) available on this platform were evaluated. Standard image quality metrics, including slice thickness accuracy, high‐contrast resolution, low‐contrast resolution, regional uniformity and noise, and CT Hounsfield unit (HU) number accuracy and linearity were evaluated using a manufacturer‐supplied QUART phantom (GmbH, Zorneding, Germany) and an independent image quality phantom (Catphan 500, The Phantom Laboratory, New York, NY). Due to the simplified design of the QUART phantom, we developed surrogate and clinically feasible strategies for measuring slice thickness and high‐ and low‐contrast resolution. Imaging dose delivered by these eleven protocols was measured using a computed tomography dose index phantom and pencil chamber with commonly accepted methods and procedures. A subset of measurements were repeated on a conventional C‐arm LINAC (TrueBeam and Trilogy, Varian Medical System) for comparison. Clinical patient images of pelvic and abdominal regions are also presented for qualitative assessment as part of a feasibility study for clinical implementation.Results: Image acquisition time was 17–42 s on the Halcyon system compared with 60 s on the C‐arm LINAC systems. The kV imager projection offset, imaging and treatment isocenter coincidence and the couch three‐dimensional match movement all achieved less than1 mm mechanical accuracy. All major image quality metrics were within either the national guideline or vendor‐recommended tolerances. The designed surrogate approach with the QUART phantom showed a range of 0.24–0.35 cycles/mm for spatial resolution, a contrast‐to‐noise ratio (CNR) of 2–20 for FDK reconstruction and a tolerance of 0.5 mm for slice thickness. Other metrics derived from the Catphan images obtained on the Halcyon and C‐arm LINACs showed comparable values for the FDK reconstruction. The iterative reconstruction tended to reduce noise, as evidenced by a higher CNR ratio. The fast scan pelvis protocols for Halcyon resulted in 50% lower dose compared to the standard scans, and the thorax fast protocol similarly delivered 10% lower dose than the standard thoracic scan. Preliminary patient images indicated that rapid kV CBCT with breath‐hold is feasible, with improved imaging quality compared to free‐breathing scans.Conclusion: Independent and comprehensive characterization of the kV imaging guidance system on the Halcyon 2.0 system demonstrated acceptable image quality for clinical use. The imaging unit onboard the Halcyon meets vendor specifications and satisfies requirements for routine clinical use. The fast kV imaging system enables the potential for volumetric CBCT acquisition during a single breath‐hold and the iterative reconstruction tends to reduce the noise therefore has the potential to improve the CNR for normal size patient.

31 August 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
KLKaiyan Li
Kaiyan Li
WZWeimin Zhou
Weimin Zhou
HLHua Li
Hua Li
MAMark Anastasio
Mark Anastasio
A variety of deep neural network (DNN)-based image denoising methods have been proposed for use with medical images. Traditional measures of image quality (IQ) have been employed to optimize and evaluate these methods. However, the objective evaluation of IQ for the DNN-based denoising methods remains largely lacking. In this work, we evaluate the performance of DNN-based denoising methods by use of task-based IQ measures. Specifically, binary signal detection tasks under signal-known-exactly (SKE) with background-known-statistically (BKS) conditions are considered. The performance of the ideal observer (IO) and common linear numerical observers are quantified and detection efficiencies are computed to assess the impact of the denoising operation on task performance. The numerical results indicate that, in the cases considered, the application of a denoising network can result in a loss of task-relevant information in the image. The impact of the depth of the denoising networks on task performance is also assessed. The presented results highlight the need for the objective evaluation of IQ for DNN-based denoising technologies and may suggest future avenues for improving their effectiveness in medical imaging applications.

1 February 2021 in Medical Image Analysis
Verified
Journal Article
Closed access
SHShenghua He
Shenghua He
KMKyaw Thu Minn
Kyaw Thu Minn
LSLilianna Solnica-Krezel
Lilianna Solnica-Krezel
MAMark Anastasio
Mark Anastasio
HLHua Li
Hua Li

13 September 2023 in Medical Image Analysis
Verified
Journal Article
Closed access
ZFZong Fan
Zong Fan
PGPing Gong
Ping Gong
STShanshan Tang
Shanshan Tang
CLChristine U. Lee
Christine U. Lee
XZXiaohui Zhang
Xiaohui Zhang
HLHua Li
Hua Li

16 November 2021 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
XZXiaohui Zhang
Xiaohui Zhang
VKVarun Kelkar
Varun Kelkar
JGJason Granstedt
Jason Granstedt
HLHua Li
Hua Li
MAMark Anastasio
Mark Anastasio
Single-image super-resolution (SISR) is a classic image restoration operation that seeks to estimate a high-resolution (HR) image from an observed low-resolution (LR) one.1 A variety of methods have been developed to achieve this goal, such as filtering and interpolation-based approaches2 and more formal regularized inverse problem-based formulations,3,4 to name a few. Recently, deep learning-based image super-resolution (DL-SR) methods have been widely employed and have shown great promise for SISR in terms of traditional image quality (IQ) metrics such as mean square error (MSE), structural similarity index metric (SSIM), and peak-signal-to-noise ratio (PSNR).5 – 8