Weiyu Guo

Weiyu Guo

Auto-generated profile, based on publicly available information

Weiyu Guo

Thrust of Artificial Intelligence, The Hong Kong University of Science and Technology (Guangzhou), Guangzhou, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2022
Verified
Book Chapter
Closed access
PDF file
WGWeiyu Guo
Weiyu Guo
ZLZhaoshuo Li
Zhaoshuo Li
YYYongkui Yang
Yongkui Yang
ZWZheng Wang
Zheng Wang
RTRussell H. Taylor
Russell H. Taylor
YLYingwei Li
Yingwei Li

29 March 2023 in IEEE Transactions on Human-Machine Systems
Verified
Journal Article
Closed access
WGWeiyu Guo
Weiyu Guo
NJNing Jiang
Ning Jiang
DFDario Farina
Dario Farina
JSJingyong Su
Jingyong Su
ZWZheng Wang
Zheng Wang
HXHui Xiong
Hui Xiong
Simultaneous and proportional control (SPC) based on surface electromyographic (sEMG) signals has led to a broad range of applications. However, due to the limitation in the generalization and stability of current machine learning algorithms, these methods can only estimate less than 15 simultaneuous and proportional (SP) categories of finger movement. In this article, a novel deep learning algorithm, named multiattention feature fusion network (MAFN), is proposed to estimate comprehensive finger movement (up to 28 categories SP movements) from sEMG signals. MAFN is based on the multihead attention mechanism, which adaptively extracts essential features for analyzing the joint angles from the extracted sEMG features. Furthermore, a real-time exponential smoothing algorithm is designed for further improvement of the prediction stability. MAFN was evaluated on 28 finger movements of 38 subjects in the Ninapro_db2 dataset, and benchmarked with the state-of-the-art methods, such as temporal convolutional network (TCN) and long short term memory network (LSTM). The results demonstrated that the average Pearson correlation coefficient, root mean squared error of MAFN (0.84 ± 0.03,0.09 ± 0.01) were significantly higher than those of TCN (0.52 ± 0.06, p < 0.001;0.16 ± 0.02, p < 0.001) and LSTM (0.62 ± 0.06, p < 0.001;0.13 ± 0.01, p < 0.001). These improvements led to more stable and accurate movement predictions. Additionally, the time delay and power consumption of MAFN when applied to sEMG signals on a portable device are only 83.4 ms and 3 W, which implies prospective commercial applications.

26 October 2023
Verified
Conference Paper
Open access
HZHe Zhang
He Zhang
YSYing Sun
Ying Sun
WGWeiyu Guo
Weiyu Guo
YLYafei Liu
Yafei Liu
HLHaonan Lu
Haonan Lu
HXHui Xiong
Hui Xiong

11 December 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
CLChuang Lin
Chuang Lin
CZChunxiao Zhao
Chunxiao Zhao
JZJianhua Zhang
Jianhua Zhang
CCChen Chen
Chen Chen
NJNing Jiang
Ning Jiang
WGWeiyu Guo
Weiyu Guo
Surface Electromyographic (sEMG) signals contain motor-related information and therefore can be used for human-machine interaction (HMI). Deep learning plays an important role in extracting motor-related information from sEMG signals. However, most studies prioritize model accuracy without sufficient consideration of model efficiency, including the model size, power consumption, and the computational speed of the model. This leads to impractical power consumption, heat dissipation levels and processing time in wearable computation scenarios. Here, we propose an efficient Transformer method that employs the EMSA (Efficient Multiple Self-Attention) and pruning mechanism to improve efficiency and accuracy concurrently, when estimating finger joint angles from sEMG signals. The proposed method does not only achieve state-of-the-art accuracy but can also be deployed on wearable devices to satisfy real-time applications. We applied the proposed model on the Ninapro DB2-dataset to estimate finger joint angles during grasping tasks. RNN series models, Convolution series models, and Transformer series models were used as reference models for comparison. In addition to common model accuracy, the deployment performance of the models was tested on microprocessors, such as Intel CPU i5, Apple M1, and Raspberry Pi 4B. When tested on 38 subjects of the Ninapro DB2, the proposed model resulted in a correlation coefficient of $0.82~\pm ~0.04$ , root mean squared error (RMSE) of $10.77~\pm ~1.48$ , and normalized RMSE of $0.11~\pm ~0.01$ , which were all similar to the results achieved by the state-of-the-art (SOTA) reference methods. Further, the computational time of the proposed methods was 65.99 ms on the Raspberry Pi 4B, which outperformed all the RNN series models and the Transformer series models. The model size and the power (the minimum size and power are 0.39 MB and 2.28 w) consumption of the proposed model also outperformed that of all reference Transformer methods. These experimental results indicate that our model can maintain the accuracy of the SOTA methods while significantly improving efficiency, thus being a promising approach for real-life applications in wearable devices.

16 April 2024 in Pattern Recognition
Verified
Journal Article
Closed access
ZQZiyue Qiao
Ziyue Qiao
Meng XiaoMeng Xiao
Meng Xiao
WGWeiyu Guo
Weiyu Guo
XLXiao Luo
Xiao Luo
HXHui Xiong
Hui Xiong