Susan E D'AAndrea

Susan E D'AAndrea

Auto-generated profile, based on publicly available information

Susan E D'AAndrea

University of Rhode Island

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2001 in Journal of Biomechanics
Verified
Journal Article
Closed access
GPGail P Perusek
Gail P Perusek
BDBrian L Davis
Brian L Davis
ACAmy C Courtney
Amy C Courtney
SDSusan E D’aNdrea
Susan E D’aNdrea

26 April 2024 in JMIR Research Protocols
Verified
Journal Article
Open access
JMJason T Maikos
Jason T Maikos
JCJohn M Chomack
John M Chomack
DHDavid V Herlihy
David V Herlihy
DPDavid N Paglia
David N Paglia
CWCharlene Wetterstrand
Charlene Wetterstrand
SDSusan E D'ANdrea
Susan E D'ANdrea
Background: Relative motion between the residual limb and socket in individuals with transtibial limb loss can lead to substantial consequences that limit mobility. Although assessments of the relative motion between the residual limb and socket have been performed, there remains a substantial gap in understanding the complex mechanics of the residual limb-socket interface during dynamic activities that limits the ability to improve socket design. However, dynamic stereo x-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and skin deformation inside a socket during dynamic activities. Objective: This study aims to develop analytical tools using DSX to quantify the dynamic, in vivo kinematics between the residual limb and socket and the mechanism of residual tissue deformation. Methods: A lower limb cadaver study will first be performed to optimize the placement of an array of radiopaque beads and markers on the socket, liner, and skin to simultaneously assess dynamic tibial movement and residual tissue and liner deformation. Five cadaver limbs will be used in an iterative process to develop an optimal marker setup. Stance phase gait will be simulated during each session to induce bone movement and skin and liner deformation. The number, shape, size, and placement of each marker will be evaluated after each session to refine the marker set. Once an optimal marker setup is identified, 21 participants with transtibial limb loss will be fitted with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested in the DSX system to track tibial, skin, and liner motion under both suspension techniques during 3 activities: treadmill walking at a self-selected speed, at a walking speed 10% faster, and during a step-down movement. The performance of the 2 suspension techniques will be evaluated by quantifying the 3D bone movement of the residual tibia with respect to the socket and quantifying liner and skin deformation at the socket-residuum interface. Results: This study was funded in October 2021. Cadaver testing began in January 2023. Enrollment began in February 2024. Data collection is expected to conclude in December 2025. The initial dissemination of results is expected in November 2026. Conclusions: The successful completion of this study will help develop analytical methods for the accurate assessment of residual limb-socket motion. The results will significantly advance the understanding of the complex biomechanical interactions between the residual limb and the socket, which can aid in evidence-based clinical practice and socket prescription guidelines. This critical foundational information can aid in the development of future socket technology that has the potential to reduce secondary comorbidities that result from complications of poor prosthesis load transmission. International Registered Report Identifier (IRRID): DERR1-10.2196/57329

13 February 2024 in JMIR Preprints
Verified
Preprint
Open access
JMJason T Maikos
Jason T Maikos
JCJohn M Chomack
John M Chomack
DHDavid V Herlihy
David V Herlihy
DPDavid N Paglia
David N Paglia
CWCharlene Wetterstrand
Charlene Wetterstrand
SDSusan E D'Andrea
Susan E D'Andrea
BACKGROUND Relative motion between the residual limb and socket in individuals with transtibial limb loss can lead to substantial consequences that limit mobility. Although assessments of the relative motion between the residual limb and socket have been performed, there remains a substantial gap in understanding the complex mechanics of the residual limb-socket interface during dynamic activities that limits the ability to improve socket design. However, dynamic stereo x-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and skin deformation inside a socket during dynamic activities. OBJECTIVE This study aims to develop analytical tools using DSX to quantify the dynamic, in vivo kinematics between the residual limb and socket and the mechanism of residual tissue deformation. METHODS A lower limb cadaver study will first be performed to optimize the placement of an array of radiopaque beads and markers on the socket, liner, and skin to simultaneously assess dynamic tibial movement and residual tissue and liner deformation. Five cadaver limbs will be used in an iterative process to develop an optimal marker setup. Stance phase gait will be simulated during each session to induce bone movement and skin and liner deformation. The number, shape, size, and placement of each marker will be evaluated after each session to refine the marker set. Once an optimal marker setup is identified, 21 participants with transtibial limb loss will be fitted with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested in the DSX system to track tibial, skin, and liner motion under both suspension techniques during 3 activities: treadmill walking at a self-selected speed, at a walking speed 10% faster, and during a step-down movement. The performance of the 2 suspension techniques will be evaluated by quantifying the 3D bone movement of the residual tibia with respect to the socket and quantifying liner and skin deformation at the socket-residuum interface. RESULTS This study was funded in October 2021. Cadaver testing began in January 2023. Enrollment began in February 2024. Data collection is expected to conclude in December 2025. The initial dissemination of results is expected in November 2026. CONCLUSIONS The successful completion of this study will help develop analytical methods for the accurate assessment of residual limb-socket motion. The results will significantly advance the understanding of the complex biomechanical interactions between the residual limb and the socket, which can aid in evidence-based clinical practice and socket prescription guidelines. This critical foundational information can aid in the development of future socket technology that has the potential to reduce secondary comorbidities that result from complications of poor prosthesis load transmission. INTERNATIONAL REGISTERED REPORT DERR1-10.2196/57329

2 July 2026 in Medical Engineering & Physics
Verified
Journal Article
Open access
DHDavid Vincent Herlihy
David Vincent Herlihy
JCJohn M Chomack
John M Chomack
DPDavid Paglia
David Paglia
CWCharlene Elizabeth Wetterstrand
Charlene Elizabeth Wetterstrand
JOJ. Patrick O'Connor
J. Patrick O'Connor
JMJason T Maikos
Jason T Maikos
Understanding the biomechanical interaction between residual limbs and prosthetic sockets is essential for optimizing prosthesis design and minimizing tissue injury. Existing cadaveric stance simulators have not been specifically designed to examine socket-residual limb biomechanics. This study designed, constructed, and evaluated a cadaveric stance simulator capable of applying physiologically representative compressive forces through residual limbs within sockets. The long-term objective is to utilize dynamic stereo x-ray (DSX) to quantify 3D skin strain at the socket-residual limb interface, for which this simulator serves as a critical foundational step. Methods: The simulator combined passive spring compression with active stepper motor control to generate characteristic double-peaked vertical ground reaction force (vGRF) profiles of stance phase. Primary validation was performed under idealized conditions using a rigid prosthesis configuration, with cadaveric testing as a secondary feasibility assessment on two residual limbs with direct force plate measurement. Validation metrics included peak vGRF, peak-to-valley (P2V) ratio, first-to-second peak symmetry (P2P), and loading and unloading rates, with target parameters derived from five participants with transtibial limb loss. Non-parametric analyses compared simulator outputs with control data (α = 0.05). Spring compression-based force estimates were validated against force plate measurements using root mean square (RMS) error analysis. Results: Idealized trials reproduced physiological vGRF profiles with no significant differences across validation metrics, confirming accurate stance phase loading reproduction as the primary outcome. Exploratory cadaveric comparisons demonstrated lower peak vGRF, P2V ratio, and unloading rates relative to control participants, attributable to intentional force reductions to preserve tissue integrity. Spring-based force estimates closely approximated force plate measurements. Conclusion: The stance simulator provided a repeatable, adaptable platform for physiologically representative residual limb loading. Its compatibility with DSX imaging establishes a foundation for quantifying 3D skin strain at the socket-residual limb interface, supporting the improved socket design and outcomes for individuals with lower limb loss.

27 February 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LDLauren Deus
Lauren Deus
LWLeah Wohlbach
Leah Wohlbach
SDSusan E. D’ANdrea
Susan E. D’ANdrea
Prosthetic abandonment is highly prevalent among upper extremity amputees (UEA), partly due to lack of engaging and motivating training to use their devices. Augmented reality (AR) systems can be used for rehabilitation, and are advantageous because they offer stimulating, goal-oriented experiences for participants to immerse themselves in while performing repetitive tasks to improve function. Thus, in this study, the effects of a novel AR prosthetic training game, and the transfer of skills to a functional rehabilitation performance assessment involving tasks of daily living were investigated. Thirty-two able-bodied participants, sixteen allocated to receive AR training and sixteen received no training, donned a bypass body-powered prosthetic device to engage in a functional task assessment, evaluated at two time points. The AR group used the bypass prosthesis to engage in the AR training game, ARm-Strong, on each of three training sessions. AR group participants completed a questionnaire at the end of the intervention to evaluate their feelings on the AR game. On average, individuals in the AR group were significantly more efficient at using the bypass prosthesis to complete functional tasks compared to the control group, however, the rate of improvement was similar between groups. Individuals who engaged in the AR training felt positive feelings of engagement, engrossment, and immersion towards the application although the impression of immersion was significantly less than that of engagement and engrossment. The results of this study support previous findings that AR training is an engaging and motivating experience, and motor learning can be achieved through this type of training. Future implications of the results may benefit prosthesis users by enhancing user experience during prosthetic training and ultimately lead to better rehabilitation and overall adherence to the use of the prosthetic device.