Jeffrey S. A. Stringer

Jeffrey S. A. Stringer

Auto-generated profile, based on publicly available information

Jeffrey S. A. Stringer

Department of Obstetrics and Gynecology, University of North Carolina School of Medicine, Chapel Hill, North Carolina, 27599, USA, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2021 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
DRDennis Ryu
Dennis Ryu
DKDong Hyun Kim
Dong Hyun Kim
JPJoan T. Price
Joan T. Price
JLJong Yoon Lee
Jong Yoon Lee
HCHa Uk Chung
Ha Uk Chung
SXShuai Xu
Shuai Xu
Significance: Monitoring vital signs for laboring women and their fetuses is foundational to the delivery of obstetrical care; however, monitoring platforms for pregnancy have undergone little innovation over the last several decades with many low-income settings lacking basic access. We report a new time-synchronized, flexible, and wireless sensor system applicable across the entire continuum of antepartum and postpartum care that provides continuous, comprehensive, and noninvasive monitoring (heart rate, respiratory rate, and pulse oxygenation) compatible with a wide range of mobile devices. This system offers advanced features such as continuous blood pressure, uterine electrohysterography, and automated body position classification. We further demonstrate the performance of this new system among pregnant individuals ( n = 576) in both high-resource settings and low-resource care settings.

27 January 2024 in npj Precision Oncology
Verified
Journal Article
Open access
PDF file
QDQing Dan
Qing Dan
ZXZiting Xu
Ziting Xu
HBHannah Burrows
Hannah Burrows
JBJennifer Bissram
Jennifer Bissram
JSJeffrey S. A. Stringer
Jeffrey S. A. Stringer
YLYingjia Li
Yingjia Li
Deep learning (DL) has been widely investigated in breast ultrasound (US) for distinguishing between benign and malignant breast masses. This systematic review of test diagnosis aims to examine the accuracy of DL, compared to human readers, for the diagnosis of breast cancer in the US under clinical settings. Our literature search included records from databases including PubMed, Embase, Scopus, and Cochrane Library. Test accuracy outcomes were synthesized to compare the diagnostic performance of DL and human readers as well as to evaluate the assistive role of DL to human readers. A total of 16 studies involving 9238 female participants were included. There were no prospective studies comparing the test accuracy of DL versus human readers in clinical workflows. Diagnostic test results varied across the included studies. In 14 studies employing standalone DL systems, DL showed significantly lower sensitivities in 5 studies with comparable specificities and outperformed human readers at higher specificities in another 4 studies; in the remaining studies, DL models and human readers showed equivalent test outcomes. In 12 studies that assessed assistive DL systems, no studies proved the assistive role of DL in the overall diagnostic performance of human readers. Current evidence is insufficient to conclude that DL outperforms human readers or enhances the accuracy of diagnostic breast US in a clinical setting. Standardization of study methodologies is required to improve the reproducibility and generalizability of DL research, which will aid in clinical translation and application.

27 August 2024 in JAMA
Verified
Journal Article
Closed access
PDF file
JSJeffrey S. A. Stringer
Jeffrey S. A. Stringer
TPTeeranan Pokaprakarn
Teeranan Pokaprakarn
JPJuan C. Prieto
Juan C. Prieto
BVBellington Vwalika
Bellington Vwalika
SCSrihari V. Chari
Srihari V. Chari
MKMargaret P. Kasaro
Margaret P. Kasaro
Importance: Accurate assessment of gestational age (GA) is essential to good pregnancy care but often requires ultrasonography, which may not be available in low-resource settings. This study developed a deep learning artificial intelligence (AI) model to estimate GA from blind ultrasonography sweeps and incorporated it into the software of a low-cost, battery-powered device.Objective: To evaluate GA estimation accuracy of an AI-enabled ultrasonography tool when used by novice users with no prior training in sonography.Design, Setting, and Participants: This prospective diagnostic accuracy study enrolled 400 individuals with viable, single, nonanomalous, first-trimester pregnancies in Lusaka, Zambia, and Chapel Hill, North Carolina. Credentialed sonographers established the “ground truth” GA via transvaginal crown-rump length measurement. At random follow-up visits throughout gestation, including a primary evaluation window from 14 0/7 weeks’ to 27 6/7 weeks’ gestation, novice users obtained blind sweeps of the maternal abdomen using the AI-enabled device (index test) and credentialed sonographers performed fetal biometry with a high-specification machine (study standard).Main Outcomes and Measures: The primary outcome was the mean absolute error (MAE) of the index test and study standard, which was calculated by comparing each method’s estimate to the previously established GA and considered equivalent if the difference fell within a prespecified margin of ±2 days.Results: In the primary evaluation window, the AI-enabled device met criteria for equivalence to the study standard, with an MAE (SE) of 3.2 (0.1) days vs 3.0 (0.1) days (difference, 0.2 days [95% CI, −0.1 to 0.5]). Additionally, the percentage of assessments within 7 days of the ground truth GA was comparable (90.7% for the index test vs 92.5% for the study standard). Performance was consistent in prespecified subgroups, including the Zambia and North Carolina cohorts and those with high body mass index.Conclusions and Relevance: Between 14 and 27 weeks’ gestation, novice users with no prior training in ultrasonography estimated GA as accurately with the low-cost, point-of-care AI tool as credentialed sonographers performing standard biometry on high-specification machines. These findings have immediate implications for obstetrical care in low-resource settings, advancing the World Health Organization goal of ultrasonography estimation of GA for all pregnant people.Trial Registration: ClinicalTrials.gov Identifier: NCT05433519

27 February 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KRKatelyn Rittenhouse
Katelyn Rittenhouse
BVBellington Vwalika
Bellington Vwalika
AKAlexander Keil
Alexander Keil
JWJennifer Winston
Jennifer Winston
MSMarie C.D. Stoner
Marie C.D. Stoner
JSJeffrey S A Stringer
Jeffrey S A Stringer
Globally, preterm birth is the leading cause of neonatal death with estimated prevalence and associated mortality highest in low- and middle-income countries (LMICs). Accurate identification of preterm infants is important at the individual level for appropriate clinical intervention as well as at the population level for informed policy decisions and resource allocation. As early prenatal ultrasound is commonly not available in these settings, gestational age (GA) is often estimated using newborn assessment at birth. This approach assumes last menstrual period to be unreliable and birthweight to be unable to distinguish preterm infants from those that are small for gestational age (SGA). We sought to leverage machine learning algorithms incorporating maternal factors associated with SGA to improve accuracy of preterm newborn identification in LMIC settings. This study uses data from an ongoing obstetrical cohort in Lusaka, Zambia that uses early pregnancy ultrasound to estimate GA. Our intent was to identify the best set of parameters commonly available at delivery to correctly categorize births as either preterm (<37 weeks) or term, compared to GA assigned by early ultrasound as the gold standard. Trained midwives conducted a newborn assessment (94% of newborns and achieved an area under the curve (AUC) of 0.9796. We identified a parsimonious list of variables that can be used by machine learning approaches to improve accuracy of preterm newborn identification. Our best-performing model included LMP, birth weight, twin delivery, HIV serostatus, and maternal factors associated with SGA. These variables are all easily collected at delivery, reducing the skill and time required by the frontline health worker to assess GA. ClinicalTrials.gov Identifier: NCT02738892

11 October 2022 in Communications Medicine
Verified
Journal Article
Open access
PDF file
RGRyan G. Gomes
Ryan G. Gomes
BVBellington Vwalika
Bellington Vwalika
CLChace Lee
Chace Lee
AWAngelica Willis
Angelica Willis
MSMarcin Sieniek
Marcin Sieniek
SSShravya Shetty
Shravya Shetty
Background: Fetal ultrasound is an important component of antenatal care, but shortage of adequately trained healthcare workers has limited its adoption in low-to-middle-income countries. This study investigated the use of artificial intelligence for fetal ultrasound in under-resourced settings. Methods: Blind sweep ultrasounds, consisting of six freehand ultrasound sweeps, were collected by sonographers in the USA and Zambia, and novice operators in Zambia. We developed artificial intelligence (AI) models that used blind sweeps to predict gestational age (GA) and fetal malpresentation. AI GA estimates and standard fetal biometry estimates were compared to a previously established ground truth, and evaluated for difference in absolute error. Fetal malpresentation (non-cephalic vs cephalic) was compared to sonographer assessment. On-device AI model run-times were benchmarked on Android mobile phones. Results: Here we show that GA estimation accuracy of the AI model is non-inferior to standard fetal biometry estimates (error difference −1.4 ± 4.5 days, 95% CI −1.8, −0.9, n = 406). Non-inferiority is maintained when blind sweeps are acquired by novice operators performing only two of six sweep motion types. Fetal malpresentation AUC-ROC is 0.977 (95% CI, 0.949, 1.00, n = 613), sonographers and novices have similar AUC-ROC. Software run-times on mobile phones for both diagnostic models are less than 3 s after completion of a sweep. Conclusions: The gestational age model is non-inferior to the clinical standard and the fetal malpresentation model has high AUC-ROCs across operators and devices. Our AI models are able to run on-device, without internet connectivity, and provide feedback scores to assist in upleveling the capabilities of lightly trained ultrasound operators in low resource settings.

26 May 2023 in Science Advances
Verified
Journal Article
Closed access
CECamilo A. Espinosa
Camilo A. Espinosa
WKWaqasuddin Khan
Waqasuddin Khan
Rasheda KhanamRasheda Khanam
Rasheda Khanam
SDSayan Das
Sayan Das
JKJavairia Khalid
Javairia Khalid
NANima Aghaeepour
Nima Aghaeepour
Preterm birth (PTB) is the leading cause of death in children under five, yet comprehensive studies are hindered by its multiple complex etiologies. Epidemiological associations between PTB and maternal characteristics have been previously described. This work used multiomic profiling and multivariate modeling to investigate the biological signatures of these characteristics. Maternal covariates were collected during pregnancy from 13,841 pregnant women across five sites. Plasma samples from 231 participants were analyzed to generate proteomic, metabolomic, and lipidomic datasets. Machine learning models showed robust performance for the prediction of PTB (AUROC = 0.70), time-to-delivery ( r = 0.65), maternal age ( r = 0.59), gravidity ( r = 0.56), and BMI ( r = 0.81). Time-to-delivery biological correlates included fetal-associated proteins (e.g., ALPP, AFP, and PGF) and immune proteins (e.g., PD-L1, CCL28, and LIFR). Maternal age negatively correlated with collagen COL9A1, gravidity with endothelial NOS and inflammatory chemokine CXCL13, and BMI with leptin and structural protein FABP4. These results provide an integrated view of epidemiological factors associated with PTB and identify biological signatures of clinical covariates affecting this disease.