Jong Hwa Jun

Jong Hwa Jun

Auto-generated profile, based on publicly available information

Jong Hwa Jun

Department of Ophthalmology, Keimyung University School of Medicine, 1035 Dalgubeol-daero, Dalseo-gu, Daegu, 42601, Republic of Korea.

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Seung Pil BangSeung Pil Bang
Seung Pil Bang
CYChang Yeor Yeon
Chang Yeor Yeon
NANirpesh Adhikari
Nirpesh Adhikari
SNSanjiv Neupane
Sanjiv Neupane
HKHarim Kim
Harim Kim
JJJong Hwa Jun
Jong Hwa Jun
We aimed to compare the physicochemical properties and in vivo efficacy of commercially available nanoemulsion cyclosporine A (CsA) eyedrops in benzalkonium chloride (BAC)-induced dry eye disease (DED). Particle size analysis was performed on conventional 0.05% CsA (Restasis, C-CsA) and two new types of 0.05% CsA eyedrops based on a self-nanoemulsifying drug delivery system (SNEDDS, SNEDDS-N and -T). Turbidometry, pH measurements and instability indices of each CsA solution were measured. DED was induced with BAC, and animals were treated with vehicle or CsA preparations. Tear volume and fluorescein staining scores were evaluated on days 7 and 14. Eyes were enucleated and subjected to IHC, TUNEL staining, periodic acid-Schiff (PAS) staining, real-time PCR and western blotting. Both SNEDDSs had lower and more uniform particle size distribution than C-CsA, and a similar optical density to phosphate-buffered saline and stable pH, in contrast to the high turbidity and unstable pH of C-CsA. Aqueous tear volume and fluorescein staining scores were improved in C-CsA- and SNEDDS-treated mice. Numbers of PAS-positive goblet cells and levels of inflammatory mediators were decreased by both C-CsA and SNEDDS, although SNEDDS resolved inflammation more effectively than C-CsA. Cyclosporine A eyedrops with SNEDDS have improved physicochemical properties and treatment efficacy in BAC-induced DED.

18 October 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
YLYou Hyun Lee
You Hyun Lee
Seung Pil BangSeung Pil Bang
Seung Pil Bang
KSKyu-Young Shim
Kyu-Young Shim
MSMyung-Jin Son
Myung-Jin Son
HKHarim Kim
Harim Kim
JJJong Hwa Jun
Jong Hwa Jun
Purpose: This study aimed to analyze the association of tear matrix metalloproteinase 9 (MMP-9) immunoassay with the severity of dry eye (DE) signs and symptoms through qualitative, semiquantitative, and quantitative evaluations of immunoassay band. Materials and methods: This cross-sectional study enrolled 320 eyes of 320 patients. The clinical signs of DE were assessed using the Ocular Surface Disorder Index (OSDI) score, visual analogue scale (VAS), tear breakup time (tBUT), tear volume evaluation by tear meniscometry, and staining scores of the cornea and conjunctiva by the Oxford grading scheme. The tear MMP-9 immunoassay results were interpreted using qualitative (positive or negative), semi-quantitative (reagent band density on a four-point scale: 0 = negative; 1 = weakly positive; 2 = moderately positive; 3 = strongly positive), and quantitative (ratio of reagent band density to control band density) indicators. Results: Positive MMP-9 immunoassay results were significantly related to shorter tBUT, tBUT ≤3 seconds, higher corneal staining score, corneal staining score ≥2, and conjunctival staining score ≥2. The semi-quantitative results of the MMP-9 immunoassay were positively correlated with higher corneal staining score (r = 0.122, p = 0.029) and negatively correlated with tBUT (r = -0.125, p = 0.025). However, in the quantitative analysis, none of the DE signs or symptoms were correlated to the band density of the MMP-9 immunoassay. Conclusions: The positive MMP-9 immunoassay results were related to the severity of ocular signs of DE. However, using quantitative measures of the MMP-9 immunoassay to assess the clinical severity of DE requires further investigation.

29 March 2017 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
Seung Pil BangSeung Pil Bang
Seung Pil Bang
CJChoun-Ki Joo
Choun-Ki Joo
JJJong Hwa Jun
Jong Hwa Jun
To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital’s ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α1A-adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to − 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

15 September 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Seung Pil BangSeung Pil Bang
Seung Pil Bang
MSMyeong Jin Son
Myeong Jin Son
HKHarim Kim
Harim Kim
YLYou Hyun Lee
You Hyun Lee
JJJong Hwa Jun
Jong Hwa Jun
We aimed to validate a tear MMP-9 in-situ immunoassay (InflammaDry) and to identify factors that could affect results or interpretation. Three factors were examined: sample concentration, volume, and time. Recombinant human (rh) MMP-9 (10 or 20 μl; 0, 12.5, 25, 50, 100, 200, 500, and 1,000 ng/ml) was applied to the kit and the detection limit and assay reproducibility were examined. At a rhMMP-9 volume of 10 μl (≥ 50 ng/ml), all positive results were identified by densitometry at 10 and 20 min; however, after 20 min, more than half of the nine ophthalmologists interpreted a positive result. At a rhMMP-9 volume of 20 μl (≥ 25 ng/ml), ophthalmologists and densitometry identified almost all test lines at 10 and 20 min. At 10 μl, densitometry showed a linear dose–response pattern. At 20 μl, densitometry showed a linear dose–response pattern at concentrations up to 500 ng/ml; however, full saturation was achieved at concentrations ≥ 500 ng/ml. When the same amount of rhMMP-9 was applied, the density result increased significantly upon doubling of the solvent volume (i.e., by adding the same volume of PBS to a sample). InflammaDry showed a high inter- and intra-assay coefficient of variation at 10 min (28.4% and 24.7%, respectively). The results of the MMP-9 in-situ immunoassay varied significantly depending on sample volume. Therefore, when interpreting the results, careful attention must be paid to tear volume.

10 July 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JJJong Hwa Jun
Jong Hwa Jun
YLYou Hyun Lee
You Hyun Lee
MSMyeong Jin Son
Myeong Jin Son
HKHarim Kim
Harim Kim
The tear matrix metalloproteinase-9 (MMP-9) immunoassay (Inflammadry) exhibits variable results in dry eye (DE) patients. We investigated if the tear volume in DE patients affects the results of MMP-9 immunoassay in clinical and in vitro settings. This cross-sectional study enrolled 188 eyes of 188 DE patients. The clinical symptoms and signs of DE were assessed using the Ocular Surface Disease Index and visual analog scale, strip meniscometry, tear break-up time, and tear meniscus height (TMH), area (TMA), and depth (TMD) using swept-source optical coherence tomography and corneal and conjunctival staining scores. For quantitative evaluation, the bands produced by the InflammaDry test were analyzed with ImageJ. DE subjects were grouped according to MMP-9 positivity and TMH. The InflammaDry-positive group showed greater TMH, TMA, and TMD than the MMP-9-negative group (p < 0.05). InflammaDry test band density in the high TMH group was significantly greater than that in the low and normal TMH groups (p < 0.05). InflammaDry test band density correlated positively with TMH, TMA, and TMD (all p < 0.05). InflammaDry test results were influenced by tear volume. Low tear volume in aqueous tear-deficient DE may induce false-negative results, and reflex tearing during the test may induce false-positive results.

1 December 2019 in Medicine
Verified
Journal Article
Open access
Seung Pil BangSeung Pil Bang
Seung Pil Bang
KMKun Moon
Kun Moon
JLJong-Ho Lee
Jong-Ho Lee
JJJong Hwa Jun
Jong Hwa Jun
CJChoun-Ki Joo
Choun-Ki Joo
Rationale: Opacification of monofocal intraocular lenses (IOLs) of various designs and materials has been reported. Hydrophilic acrylic IOLs are more prone to opacification than hydrophobic IOLs, but IOL surface modification by hydrophobic materials may improve biocompatibility, and few opacifications of such monofocal lenses have been reported to date. However, here we describe the characteristics of opacification of hydrophilic refractive multifocal IOLs with a hydrophobic surface modification in a cluster of patients who underwent uneventful cataract surgery. Patient Concerns: In this retrospective observational case series, the medical records of 7 patients in whom opacification of the IOL was identified after implantation of LS-313 MF30 (Lentis M plus, Oculentis), from November 2017 to May 2019, were reviewed. Diagnosis: All patients had undergone bilateral implantation of LS-313 MF30 IOLs. Ten eyes of 7 patients showed significant opacification at a mean 49.1 ± 10.2 months postoperatively. Interventions: The IOLs of 4 cases were explanted. Outcomes: All of the opacified cases had received LS-313 MF30 IOLs from February 2014 to August 2014 and experienced decreased visual acuity after 44.6 ± 10.5 months. The explanted IOLs of 4 cases were evaluated by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), Alizarin-red, and von Kossa staining. These explanted IOLs showed fine and evenly distributed, whitish deposits on the entire IOL, particularly below the surface. Although the constituent of the deposits was identified as calcium by Alizarin-red and von Kossa stain, SEM, and EDX analysis showed no surface deposits of calcium. Paraffin-embedded sections of the IOLs were prepared, and calcium deposition was confirmed by EDX analysis at the subsurface region of the IOL. Lessens: Significant opacification of these hydrophilic refractive multifocal IOLs with hydrophobic surface modification was found to be due to abnormal calcification of the subsurface of the IOL. Clinicians must be aware of the opacification of this IOL design, despite surface modification. In particular, it should be noted that there is a high likelihood that the patient may experience vision-related symptoms even with moderate opacity and that opacification may lead to a burdensome IOL exchange.