Natalia B. Golovanova

Natalia B. Golovanova

Auto-generated profile, based on publicly available information

Natalia B. Golovanova

MIREA – Russian Technological University

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2022 in Russian Technological Journal
Verified
Journal Article
Open access
PDF file
ASA. S. Sigov
A. S. Sigov
NGN. B. Golovanova
N. B. Golovanova
OMO. A. Minaeva
O. A. Minaeva
SAS. I. Anevsky
S. I. Anevsky
RSRoman V. Shamin
Roman V. Shamin
OOO. I. Ostanina
O. I. Ostanina
Objectives. In order to solve fundamental metrological problems concerning the reproduction and transmission of spectral radiometry units, as well as developing methods and tools for metrological support of modern technologies such as nanophotolithography in the electronics industry, synchrotron radiation can be used. When developing solid-state sources and receivers of radiation, new topical problems arise in connection with the metrological characteristics of light-emitting diodes (LEDs), multi-element array receivers, charge-coupled device (CCD) cameras and telescopes, whose successful solution depends on the properties of a reference source of synchrotron radiation. Therefore, the purpose of the present work is to develop spectral radiometry methods for obtaining metrological channels using an electron storage ring in order to control the characteristics of electronics components, as well as for studying and calibrating radiometers, photometers, and emitters operating in the visible, ultraviolet and infrared regions of the electromagnetic spectrum.Methods. Methods for transmitting spectroradiometric units on an electron storage ring are based on the classical theory of Julian Schwinger, which describes the electromagnetic radiation of a relativistic electron to calculate the spectral and energetic synchrotron radiation characteristics taking polarization components into account.Results. The possibility of developing methods for transmitting spectral radiometric units using synchrotron radiation was evaluated by means of a test setup, which included a monochromator-based comparator, a telescope with a CCD array, a spectroradiometer, a radiometer, a photometer, a goniometer, and an integrating sphere. This allowed the full set of spectroradiometric and photometric characteristics of radiation sources and receivers to be measured: from the most differential distribution of the spectral radiance density of the emitting region to the integral radiation flux. The results were compared with the reference synchrotron radiation source.Conclusions. Among possible approaches for determining the metrological characteristics of LED emitters, multielement array receivers, CCD cameras, and telescopes, synchrotron radiation seems to be the most promising. This approach allows the small size of the emitting region of synchrotron radiation, the Gaussian distribution of radiance over the emitting region of the synchrotron electron bunch, as well as the wide dynamic range of spectrum tuning due to changes in the energy and number of accelerated electrons, to be taken into account.

6 October 2023 in Russian Technological Journal
Verified
Journal Article
Open access
PDF file
ASAlexander S. Sigov
Alexander S. Sigov
ELE. R. Lazarenko
E. R. Lazarenko
NGN. B. Golovanova
N. B. Golovanova
OMO. A. Minaeva
O. A. Minaeva
SAS. I. Anevsky
S. I. Anevsky
PPP. Yu. Pushkin
P. Yu. Pushkin
Objectives. The investigations of optical radiation sources and metrological detector characteristics in the infrared (IR), visible, and air ultraviolet (UV) spectral regions are partially based on the unique metrological properties of synchrotron radiation. The aim of this work is to develop a high-precision method for determining the storage ring accelerated electron number with synchrotron radiation of a single electron to establish spectroradiometry and photometry units.Methods. By determining the number of accelerated electrons, any storage ring can be used to calculate the synchrotron radiation characteristics at wavelengths of many large then the critical wavelength in the visible, air UV, and IR regions of the spectrum. This makes it possible to determine the main metrological characteristics normalized to the number of electrons, such as luminous intensity, luminance, illuminance, radiant power, radiance, irradiance, etc., regardless of the energy of the electrons.Results. When applying the method for determining the number of accelerated electrons at low currents of the electronic storage ring, a total standard deviation of the number of accelerated electrons is less than 0.01% for an exposure range of the CCD matrix from 10−2 to 3 · 103 s in a wide dynamic range of 1−1010 electrons per orbit.Conclusions. The use of a CCD-based radiometer-comparator calibrated by responsivity on a synchrotron radiation source is particularly relevant in monitoring luminance contrast thresholds and spatial distribution of object and background brightness, as well as determining metrological characteristics of optoelectronic measuring instruments, including CCD cameras, radiometers, spectroradiometers and photometers.

9 April 2026 in Russian Technological Journal
Verified
Journal Article
Closed access
SKS. A. Kudzh
S. A. Kudzh
NGN. B. Golovanova
N. B. Golovanova
YGYu. G. Grafov
Yu. G. Grafov
Objectives . The work sets out to develop a comprehensive approach to grounding decisions aimed at advancing the scientific and educational infrastructure of an engineering university. This includes selecting modernization policies for the scientific and educational infrastructure, substantiating the format of scientific and educational infrastructure objects in light of the diversity of current tasks, involving industry partners in implementing infrastructure policies, as well as addressing resource support issues using mathematical formalization and analytical evaluation tools. Methods . Methods of systems and strategic analysis, comparison and formalization, modeling and statistical indicators, as well as change management, risk assessment, and strategy actualization approaches, were used. Results . Ensuring the contribution of modern engineering universities to technological leadership is an ambitious task that requires a focused approach to the development of scientific and educational infrastructure. One effective solution consists in the creation of specialized laboratories, or mega-laboratories, which are considered as an optimal format for the scientific and educational infrastructure. Such laboratories combine educational, research, and communication zones, along with their respective advantages and typologies. The importance of collaboration with industry partners in driving innovation, helping to ensure that educational programs, research, and development align with market needs, is demonstrated. A mathematical model is developed for evaluating projects associated with the establishment of a mega-laboratory based on a comprehensive system of indicators. This model was used to formalize the procedure for selecting and financing of newly created scientific and educational infrastructure. Conclusions . Infrastructure constraints defined at the state level in the context of technological development and the need to ensure technological independence are becoming a key challenge for engineering universities. This necessitates the development of tools for seeking, justifying, and making managerial decisions. The described comprehensive approach takes into account current requirements for scientific and educational infrastructure facilities, including a high degree of integration between education and science, and the involvement of industry partners in the development process in order to bridge the gap between education, science, and the demands of the real economy. The formulated recommendations and proposed solutions effectively address the issues faced by modern engineering universities within development programs.

23 September 2024
Verified
Conference Paper
Closed access
OMOlga A. Minaeva
Olga A. Minaeva
SASergey I. Anevsky
Sergey I. Anevsky
NGNatalia B. Golovanova
Natalia B. Golovanova
OVOleg E. Vinokurov
Oleg E. Vinokurov
OOOlga I. Ostanina
Olga I. Ostanina
KSKirill D. Skobelev
Kirill D. Skobelev
Task (goal of the work) Development and improvement of high-precision methods and means of metrological support for quality control of information-measuring systems when solving applied measuring tasks in priority directions of science and technology. Solution method: The method of estimation of accuracy and reliability of results of quality control of information-measuring systems is based on the use of reference sources of synchrotron radiation for plasma diagnostics, analysis of solar activity, location of remote objects, control of bactericidal effect of UV radiation, for determination of threshold values of brightness contrast and for investigation of multilayer structures of micro- and nanoelectro nics. Results: The results and implementation prospects of synchrotron radiation radiometry methods for improving the quality of spectroradiometers, radiometers and photometers in the partnership cooperation of RTU MIRE A with Kurchatov Institute and VNIIOFI are considered. Developed are the requirements for high-precision measuring instruments and standard samples adapted to polar scientific research during the realization of the project on the development and conservation of unique ecological systems of the Arctic. The principles are proposed of building digital models of high-precision measuring instruments for solving quality control problems in planning and optimization of production resources, taking into account modern approaches to quality management, standardization and production organization.