Ulfah Nadiya

Ulfah Nadiya

Auto-generated profile, based on publicly available information

Ulfah Nadiya

Research Center for Smart Mechatronics, National Research and Innovation Agency, Bandung, Indonesia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2025 in Indonesian Journal of electronics, electromedical engineering, and medical informatics
Verified
Journal Article
Open access
PDF file
UNUlfah Nadiya
Ulfah Nadiya
ASArtha Ivonita Simbolon
Artha Ivonita Simbolon
DKDwi Esti Kusumandari
Dwi Esti Kusumandari
ARAnnida Rahmawati
Annida Rahmawati
MAM Faizal Amri
M Faizal Amri
ATArjon Turnip
Arjon Turnip
Methadone is a synthetic opioid that commonly employed in opioid substitution therapy (OST) to reduce withdrawal symptoms and suppress cravings in individuals with opioid use disorder. While its pharmacological effects are well-documented, the neurophysiological changes it induces especially during acute administration remain underexplored. This study aims to address that gap by investigating methadone-induced alterations in brain oscillatory activity through electroencephalography (EEG). Specifically, it examines changes in theta (4–8 Hz), alpha (8–12 Hz), and beta (12–30 Hz) frequency bands, along with frontal alpha asymmetry (FAA) for F4-F3 and F8-F7, a biomarker associated with emotional and cognitive processing. EEG data were collected from patients enrolled in opioid rehabilitation programs both prior to and one hour following oral methadone intake. The results revealed a significant global decrease in theta power, notably within the frontal, temporal, and occipital cortices. This reduction may reflect changes in executive functioning, emotional regulation, and increased sedation. In contrast, alpha power showed a marked increase, particularly in the central, parietal, and occipital regions, suggesting reduced sensory processing and heightened sedation or attentional disengagement. Meanwhile, beta power was consistently reduced across cortical regions, pointing toward decreased cortical arousal and cognitive alertness. FAA analysis revealed high variability among participants, indicating that methadone's influence on emotional valence and approach-avoidance behavior may differ significantly across individuals. These findings underscore methadone’s sedative and stabilizing effects on neural activity and support its clinical role in managing opioid dependence. Further research into inter-individual differences in EEG responses may inform more personalized and effective OST protocols.

23 November 2022
Verified
Conference Paper
Closed access
MRMuhammad Ilham Rizqyawan
Muhammad Ilham Rizqyawan
ENEdi Triono Nuryatno
Edi Triono Nuryatno
Hanif FakhrurrojaHanif Fakhrurroja
Hanif Fakhrurroja
AMAris Munandar
Aris Munandar
JWJony winaryo Wibowo
Jony winaryo Wibowo
TSTaufik Ibnu Ibnu Salim
Taufik Ibnu Ibnu Salim
Cardiac arrhythmia is a medical term to describe an irregular heartbeat, which occurs when electrical properties in the heart incapacitated. Although most of arrhythmias are harmless, some of them can lead to life threatening complications if not detected and monitored on time. To date, a real-time automatic arrhythmia detection is essential in the current health system. This can be seen from numerous research that has been conducted on the automatic detection and classification of various types of arrhythmias. This study seeks to find as much relevant research on the abundance of published work in the topic, to identify the state-of-the art methods and finding the gap in the research in an effort to summarize all of the available evidence of the distinguish real-time automatic arrhythmia detection. A careful quantitative research process of systematic literature review (SLR) within the Health Informatics area was applied in this research to identify and analyze the trends, datasets, and methods in real-time arrhythmia detection. Systematic searches were administered in Scopus using a defined search string, while several filters were applied based on inclusion and exclusion criteria. After removing duplicates and non-eligible articles, the data were extracted from the selected articles with the result shows that the number of studies focusing on the real-time detection of arrhythmia is still limited, but on a rising trend. Finally, the analysis of the datasets, feature extraction, classification methods and a table of algorithm comparison were presented as the result of the study, which summarized the pre-eminent methods of real-time arrhythmia classification based on its average accuracy.

15 November 2023
Verified
Conference Paper
Closed access
ADAulia Darojatun
Aulia Darojatun
PHPapat Hidayatulloh
Papat Hidayatulloh
ARAnnida Rahmawati
Annida Rahmawati
ASArtha Ivonita Simbolon
Artha Ivonita Simbolon
KSKadek Heri Sanjaya
Kadek Heri Sanjaya
UNUlfah Nadiya
Ulfah Nadiya
Drowsiness can be detected by processing brainwaves that was recorded using Electroencephalography (EEG). The EEG signals consist of delta, theta, alpha, beta and gamma frequency bands. This study focuses on EEG frequency bands that were used as a feature in machine learning for drowsiness detection. The feature extractions of those signals were done by using Power Spectral Density (PSD). Several classification algorithms for drowsiness detection, including Support Vector Machine (SVM), Decision Tree (DT), Random Forest (RF), K-Nearest Neighbor (KNN), Naïve Bayes, Logistic Regression (LR), Linear Discriminant Analysis (LDA), and Quadratic Discriminant Analysis (QDA) were used in this study. The results indicate that the maximum accuracy achievable is 73.79% when using all frequency bands as a feature with the RF model. However, it should be noted that each model has different characteristics that impact their feature requirements.

23 April 2025 in Indonesian Journal of electronics, electromedical engineering, and medical informatics
Verified
Journal Article
Open access
PDF file
UNUlfah Nadiya
Ulfah Nadiya
ASArtha Ivonita Simbolon
Artha Ivonita Simbolon
DKDwi Esti Kusumandari
Dwi Esti Kusumandari
ARAnnida Rahmawati
Annida Rahmawati
MAM Faizal Amri
M Faizal Amri
ATArjon Turnip
Arjon Turnip
Methadone is a synthetic opioid that commonly employed in opioid substitution therapy (OST) to reduce withdrawal symptoms and suppress cravings in individuals with opioid use disorder. While its pharmacological effects are well-documented, the neurophysiological changes it induces—especially during acute administration—remain underexplored. This study aims to address that gap by investigating methadone-induced alterations in brain oscillatory activity through electroencephalography (EEG). Specifically, it examines changes in theta (4–8 Hz), alpha (8–12 Hz), and beta (12–30 Hz) frequency bands, along with frontal alpha asymmetry (FAA) for F4-F3 and F8-F7, a biomarker associated with emotional and cognitive processing. EEG data were collected from patients enrolled in opioid rehabilitation programs both prior to and one hour following oral methadone intake. The results revealed a significant global decrease in theta power, notably within the frontal, temporal, and occipital cortices. This reduction may reflect changes in executive functioning, emotional regulation, and increased sedation. In contrast, alpha power showed a marked increase, particularly in the central, parietal, and occipital regions, suggesting reduced sensory processing and heightened sedation or attentional disengagement. Meanwhile, beta power was consistently reduced across cortical regions, pointing toward decreased cortical arousal and cognitive alertness. FAA analysis revealed high variability among participants, indicating that methadone's influence on emotional valence and approach-avoidance behavior may differ significantly across individuals. These findings underscore methadone’s sedative and stabilizing effects on neural activity and support its clinical role in managing opioid dependence. Further research into inter-individual differences in EEG responses may inform more personalized and effective OST protocols.