14 August 2014 in Journal of Cardiovascular Electrophysiology
MAMaría José Angulo‐Hernández
María José Angulo‐Hernández
JPJulián Pérez‐Villacastín
+7
4 August 2023 in Nature Communications
DEDaniel Enríquez-Vázquez
+26
Electromechanical characterization during atrial fibrillation (AF) remains a significant gap in the understanding of AF-related atrial myopathy. This study reports mechanistic insights into the electromechanical remodeling process associated with AF progression and further demonstrates its prognostic value in the clinic. In pigs, sequential electromechanical assessment during AF progression shows a progressive decrease in mechanical activity and early dissociation from its electrical counterpart. Atrial tissue samples from animals with AF reveal an abnormal increase in cardiomyocytes death and alterations in calcium handling proteins. High-throughput quantitative proteomics and immunoblotting analyses at different stages of AF progression identify downregulation of contractile proteins and progressive increase in atrial fibrosis. Moreover, advanced optical mapping techniques, applied to whole heart preparations during AF, demonstrate that AF-related remodeling decreases the frequency threshold for dissociation between transmembrane voltage signals and intracellular calcium transients compared to healthy controls. Single cell simulations of human atrial cardiomyocytes also confirm the experimental results. In patients, non-invasive assessment of the atrial electromechanical relationship further demonstrate that atrial electromechanical dissociation is an early prognostic indicator for acute and long-term rhythm control.
1 October 2015 in Heart Rhythm
JPJulián Pérez-Villacastín
+6
23 April 2013 in Cardiovascular Research
NPNicasio Pérez-Castellano
JPJulián Pérez-Villacastín
+6
Aims The mechanisms underlying ventricular fibrillation (VF) are still disputed. Recent studies have highlighted the role of KATP-channels. We hypothesized that, under certain conditions, VF can be driven by stable and epicardially detectable rotors in large hearts. To test our hypothesis, we used a swine model of accelerated VF by opening KATP-channels with cromakalim. Methods and results Optical mapping, spectral analysis, and phase singularity tracking were performed in eight perfused swine hearts during VF. Pseudo-bipolar electrograms were computed. KATP-channel opening almost doubled the maximum dominant frequency (14.3 ± 2.2 vs. 26.5 ± 2.8 Hz, P < 0.001) and increased the maximum regularity index (0.82 ± 0.05 vs. 0.94 ± 0.04, P < 0.001), the density of rotors (2.0 ± 1.4 vs. 16.0 ± 7.0 rotors/cm2×s, P < 0.001), and their maximum lifespans (medians: 368 vs. ≥3410 ms, P < 0.001). Persistent rotors (≥1 movie = 3410 ms) were found in all hearts after cromakalim (mostly coinciding with the fastest and highest organized areas), but they were not epicardially visible at baseline VF. A ‘beat phenomenon’ ruled by inter-domain frequency gradients was observed in all hearts after cromakalim. Acceleration of VF did not reveal any significant regional preponderance. Complex fractionated electrograms were not found in areas near persistent rotors. Conclusion Upon KATP-channel opening, VF consisted of rapid and highly organized domains mainly due to stationary rotors, surrounded by poorly organized areas. A ‘beat phenomenon’ due to the quasi-periodic onset of drifting rotors was observed. These findings demonstrate the feasibility of a VF driven by stable rotors in hearts whose size is similar to the human heart. Our model also showed that complex fractionation does not seem to localize stationary rotors.
23 March 2006 in Journal of Cardiovascular Electrophysiology
1 November 2017 in Progress in Biophysics and Molecular Biology