Tianzheng Wang

Tianzheng Wang

Auto-generated profile, based on publicly available information

Tianzheng Wang

Shanxi Electric Power Research Institute, Taiyuan 030000, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2020 in Molecules
Verified
Journal Article
Open access
PDF file
XWXinwei Wang
Xinwei Wang
SLShan Lu
Shan Lu
TWTianzheng Wang
Tianzheng Wang
QXQIN XINRAN
QIN XINRAN
XWXilin Wang
Xilin Wang
ZJZhidong Jia
Zhidong Jia
Surface pollution deposition in a high voltage surface can reduce the surface flashover voltage, which is considered to be a serious accident in the transmission of electric power for the high conductivity of pollution in wet weather, such as rain or fog. Accordingly, a rapid and accurate online pollution detection method is of great importance for monitoring the safe status of transmission lines. Usually, to detect the equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD), the pollution should be collected when power cut off and bring back to lab, time-consuming, low accuracy and unable to meet the online detection. Laser-induced breakdown spectroscopy (LIBS) shows the highest potential for achieving online pollution detection, but its application in high voltage electrical engineering has only just begun to be examined. In this study, a LIBS method for quantitatively detecting the compositions of pollutions on the insulators was investigated, and the spectral characteristics of a natural pollution sample were examined. The energy spectra and LIBS analysis results were compared. LIBS was shown to detect pollution elements that were not detected by conventional energy spectroscopy and had an improved capacity to determine pollution composition. Furthermore, the effects of parameters, such as laser energy intensity and delay time, were investigated for artificial pollutions. Increasing the laser energy intensity and selecting a suitable delay time could enhance the precision and relative spectral intensities of the elements. Additionally, reducing the particle size and increasing the density achieved the same results.

10 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLShan Lu
Shan Lu
XWXinwei Wang
Xinwei Wang
TWTianzheng Wang
Tianzheng Wang
QXQIN XINRAN
QIN XINRAN
XWXilin Wang
Xilin Wang
ZJZhidong Jia
Zhidong Jia
The composition of contamination deposited on transmission line insulators can affect their surface flashover voltage. Currently, there is no rapid on-line method to detect this contamination composition in power grids. In this paper, we applied laser-induced breakdown spectroscopy (LIBS) to analyze contamination on insulator surfaces. Usually, Na and Ca salts are found in contamination along with various sulfate, carbonate, and chloride compounds. As an element’s detection method, LIBS can only measure a certain element content, for example, Ca. The mixture of various compounds with the same cations can influence the LIBS signal. The influence of mixing ratios on the calibration curves and relative spectral intensity was studied via LIBS. Na2CO3, NaHCO3, CaSO4, and CaCO3 samples containing different proportions of Na and Ca were prepared. The linear correlation coefficients (R2) for the Na and Ca calibration curves generated using various mixing ratios were analyzed. The results showed that the mixture ratio did not dramatically affect the linear calibration curves for mixtures containing the same cations. This finding may significantly reduce the difficulty of applying LIBS analysis for complex contamination on insulators. The laser energy density had effects on the spectral characteristics of the measured elements. The partial least-square regression (PLSR) model can improve the accuracy of Na and Ca prediction.

19 May 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
YLYanpeng Li
Yanpeng Li
TWTianzheng Wang
Tianzheng Wang
LBLu Bai
Lu Bai
ZLZhumao Lu
Zhumao Lu
LMLiqiang Ma
Liqiang Ma
In the research data about power quality, it is shown that voltage sag is the worst power quality problem, which can bring the most losses in various power quality problems. Dynamic voltage restorer (DVR) is the most effective solution to suppress the voltage sag. The compensation effect of DVR can be affected by the compensation strategy. Based on the analysis of existing compensation strategy, the optimized compensation strategy of load voltage is proposed in this paper. The simulation results show that the optimized compensation strategy can give attention to both the capacity of DVR and the compensation effect of the load side voltage.

25 April 2019
Verified
Book Chapter
Closed access
PDF file
TWTianzheng Wang
Tianzheng Wang
ZLZhumao Lu
Zhumao Lu
SFShaohui Feng
Shaohui Feng
HYHua Yu
Hua Yu
YLYongxin Liu
Yongxin Liu