Mattias B Nielsen

Mattias B Nielsen

Auto-generated profile, based on publicly available information

Mattias B Nielsen

Bone & Joint Research Laboratory Department of Veterans Affairs Salt Lake City, UT United States

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2019 in JMIR Research Protocols
Verified
Journal Article
Open access
DWDustin Williams
Dustin Williams
RERichard T Epperson
Richard T Epperson
NTNicholas B Taylor
Nicholas B Taylor
MNMattias B Nielsen
Mattias B Nielsen
BKBrooke S Kawaguchi
Brooke S Kawaguchi
BIBrad M Isaacson
Brad M Isaacson
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Heterotopic ossification (HO) is a significant complication for wounded warriors with traumatic limb loss. Although this pathologic condition negatively impacts the general population, ectopic bone has been observed with higher frequency for those injured in theatre. Several factors including a traumatic blast, bioburden, tourniquet and wound vacuum usage, and/or bone fractures/fragments have been associated with the increased HO formation for service members. The first step in assessing the effect of these factors on HO formation in a large animal model was to establish a repeatable and reproducible high pressure air system that could simulate a battlefield-relevant blast Objective: N/A Methods: The repeatability and reproducibility of a high-power air delivery system was determined by collecting force data across a spectrum of PSI settings. In addition, the ability of the higher power air delivery system to affect host tissue, displace metal particulate and disperse bone chips was assessed in cadaveric sheep limbs. Results: Data demonstrated that the air delivery setup could generate battlefield-relevant blast forces. Dispersion data likewise indicated that the delivery system would have the ability to cause host tissue trauma and effectively disperse metal particulate and/or host bone chips in local musculature. Conclusions: Taken together, data showed that a high pressure air impact device will have the ability to function as a simulated battlefield blast scenario and allow factors including blast trauma to translate toward a large animal model. Clinical Trial: N/A

4 September 2018 in JMIR Preprints
Verified
Preprint
Open access
DWDustin Williams
Dustin Williams
RERichard T Epperson
Richard T Epperson
NTNicholas B Taylor
Nicholas B Taylor
MNMattias B Nielsen
Mattias B Nielsen
BKBrooke S Kawaguchi
Brooke S Kawaguchi
BIBrad M Isaacson
Brad M Isaacson
BACKGROUND Heterotopic ossification (HO) is a significant complication for wounded warriors with traumatic limb loss. Although this pathologic condition negatively impacts the general population, ectopic bone has been observed with higher frequency for service members injured in Iraq and Afghanistan due to blast injuries. Several factors, including a traumatic insult, bioburden, tourniquet and wound vacuum usage, and bone fractures or fragments have been associated with increased HO for service members. A large combat-relevant animal model is needed to further understand ectopic bone etiology and develop new pragmatic solutions for reducing HO formation and recurrence. OBJECTIVE This study outlines the optimization of a blast system that may be used to simulate combat-relevant trauma for HO and replicate percussion blast experienced in theater. METHODS We tested the repeatability and reproducibility of an air impact device (AID) at various pressure settings and compared it with a model of blunt force trauma for HO induction. Furthermore, we assessed the ability of the higher-power air delivery system to injure host tissue, displace metal particulate, and disperse bone chips in cadaveric sheep limbs. RESULTS Data demonstrated that the air delivery setup generated battlefield-relevant blast forces. When the AID was charged to 40, 80, and 100 psi, the outputs were 229 (SD 13) N, 778 (SD 50) N, and 1085 (SD 114) N, respectively, compared with the blunt force model which proposed only 168 (SD 11) N. For the 100-psi AID setup, the force equaled a 5.8-kg charge weight of trinitrotoluene at a standoff distance of approximately 2.62 m, which would replicate a dismounted improvised explosive device blast in theater. Dispersion data showed that the delivery system would have the ability to cause host tissue trauma and effectively disperse metal particulate and host bone chips in local musculature compared with the standard blunt force model (13 mm vs 2 mm). CONCLUSIONS Our data showed that a high-pressure AID was repeatable or reproducible, had the ability to function as a simulated battlefield blast that can model military HO scenarios, and will allow for factors including blast trauma to translate toward a large animal model.