Taehyeong Kim

Taehyeong Kim

Auto-generated profile, based on publicly available information

Taehyeong Kim

KOCED CMI, Yongin-si, Gyeonggi-do 17058, Korea

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2022 in Engineering Structures
Verified
Journal Article
Open access
EBEun-Rim Baek
Eun-Rim Baek
DPDaniel A Pohoryles
Daniel A Pohoryles
Stylianos KalliorasStylianos Kallioras
Stylianos Kallioras
DBD.A. Bournas
D.A. Bournas
HCH. Choi
H. Choi
TKT. Kim
T. Kim

30 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DJDae-Sung Jung
Dae-Sung Jung
SPSe-Hyun Park
Se-Hyun Park
TKTae-Hyeong Kim
Tae-Hyeong Kim
JHJong-Wook Han
Jong-Wook Han
CKChul-Young Kim
Chul-Young Kim
Welded headed studs are used to connect steel girders and concrete slabs in steel composite bridges. However, environmental problems related to welded shear connectors have been reported, including noise and dust generation during the replacement and demolition of damaged or worn concrete slabs. To overcome these issues, demountable shear connectors that enable easy replacement of damaged or worn concrete slabs must be developed. However, conventional bolted shear connectors mainly use embedded nuts, which cannot be used in structures such as bridges because initial slip occurs and the stiffness and shear resistance strength are relatively low. To address these issues, this paper proposes a bolted shear connector that integrates the embedded nut part into the stud bolt and has a tapered shape at the bottom of the expansion column. For performance verification in regard to static shear strength and slip displacement, push-out tests were performed according to Eurocode-4, and the performance of the proposed stud bolt was compared to those of conventional welded headed studs and embedded nut-style bolted shear connectors. In addition, an analytical review was performed using the ABAQUS program for the 1/4 axisymmetric model of the push-out test. As a result of applying the material nonlinear model and the surface contact analysis, the load-slip displacement of each analysis model showed a tendency extremely similar to the experimental results. The proposed demountable bolted shear connector exhibited excellent shear performance and can be used as a satisfactory replacement for conventional welded studs because it meets slip displacement and ductility standards.

2 September 2016 in Sustainability
Verified
Journal Article
Open access
PDF file
EPEunil Park
Eunil Park
THTaeil Han
Taeil Han
TKTaehyeong Kim
Taehyeong Kim
SKSangjib Kwon
Sangjib Kwon
APAngel P. Del Pobil
Angel P. Del Pobil
In order to minimize the social and environmental concerns arising from the use of traditional energy resources such as fossil fuels and nuclear energy, the South Korean government has attempted to develop alternative energy resources. In particular, the large educational institutes and islands in South Korea—which have the motivation and potential to provide electrical services—are required to install renewable electricity generation facilities to reduce the burden on the local grid systems. With this trend, the current study investigates potential configurations of renewable electricity generation systems to supply the electrical demand of Jeju National University, located on the largest island in South Korea. The potential configurations suggested by the simulation results are evaluated by renewable fraction, cost of energy (COE), and total net present cost (NPC). The suggested configurations show a renewable fraction of 1.00 with COE of $0.356–$0.402 per kWh and NPC of $54,620,352–$51,795,040. Based on the results, both implications and limitations are examined.