4 October 2012 in Critical Care
Introduction: Sepsis-associated delirium (SAD) increases morbidity in septic patients and, therefore, factors contributing to SAD should be further characterized. One possible mechanism might be the impairment of cerebrovascular autoregulation (AR) by sepsis, leading to cerebral hypo- or hyperperfusion in these haemodynamically unstable patients. Therefore, the present study investigates the relationship between the incidence of SAD and the status of AR during sepsis. Methods: Cerebral blood flow velocity was measured using transcranial Doppler sonography and was correlated with the invasive arterial blood pressure curve to calculate the index of AR Mx (Mx>0.3 indicates impaired AR). Mx was measured daily during the first 4 days of sepsis. Diagnosis of a SAD was performed using the confusion assessment method for ICU (CAM-ICU) and, furthermore the predominant brain electrical activity in electroencephalogram (EEG) both at day 4 after reduction of sedation to RASS >-2. Results: 30 critically ill adult patients with severe sepsis or septic shock (APACHE II 32 ± 6) were included. AR was impaired at day 1 in 60%, day 2 in 59%, day 3 in 41% and day 4 in 46% of patients; SAD detected by CAM-ICU was present in 76 % of patients. Impaired AR at day 1 was associated with the incidence of SAD at day 4 (p = 0.035). Conclusions: AR is impaired in the great majority of patients with severe sepsis during the first two days. Impaired AR is associated with SAD, suggesting that dysfunction of AR is one of the trigger mechanisms contributing to the development of SAD. Trial registration: clinicalTrials.gov ID NCT01029080
1 February 2014 in European Journal of Anaesthesiology
Robotic assisted prostatic surgery is frequently used because of its reduced side-effects compared with conventional surgery. During surgery, an extreme Trendelenburg position and CO2 pneumoperitoneum are necessary, which may lead to cerebral oedema, can potentially reduce brain perfusion and therefore could impair cerebral oxygenation. Cerebral oxygen saturation can be measured non-invasively using near-infrared spectroscopy (NIRS). The hypothesis of the present study was that steep Trendelenburg positioning during robotic assisted prostatic surgery impairs cerebral oxygen saturation measured using two different NIRS monitors. Clinical observational study. Primary care university hospital, study period from March 2012 to February 2013. A total of 29 patients scheduled for robotic assisted prostatic surgery in a steep Trendelenburg position. Cerebral oxygen saturation was measured throughout anaesthesia using the INVOS sensor (a trend monitor using two infrared wavelengths) for one hemisphere and the FORE-SIGHT sensor (a monitor using four wavelengths of laser light to calculate absolute oxygen saturation) for the other hemisphere in an alternate randomisation. Changes in cerebral oxygenation of more than 5% during surgery in the Trendelenburg position. The median duration of Trendelenburg positioning was 190 (interquartile range 130 to 230) min. Cerebral oxygen saturation decreased with INVOS from 74 ± 5% at baseline to a lowest value of 70 ± 4% with a slope of -0.0129 min(-1) (P < 0.01) and with FORE-SIGHT from 72 ± 5% at baseline to a nadir of 70 ± 3% with a slope of -0.008 min(-1) (P < 0.01). Comparing INVOS with FORE-SIGHT, there was a good association, with a slope of 0.86 ± 0.04 (P < 0.01). Both monitors showed a clinically irrelevant decrease in cerebral oxygen saturation of less than 5% over 4 h in a steep Trendelenburg position combined with CO2 pneumoperitoneum in patients undergoing robotic assisted prostatic surgery. This extreme positioning seems to be acceptable with regard to cerebral oxygenation. clinicaltrials.gov Identifier: ID NCT01275898.
17 January 2011 in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
Background Out-of-hospital endotracheal intubation performed by paramedics using the Macintosh blade for direct laryngoscopy is associated with a high incidence of complications. The novel technique of video laryngoscopy has been shown to improve glottic view and intubation success in the operating room. The aim of this study was to compare glottic view, time of intubation and success rate of the McGrath® Series 5 and GlideScope® Ranger video laryngoscopes with the Macintosh laryngoscope by paramedics. Methods Thirty paramedics performed six intubations in a randomised order with all three laryngoscopes in an airway simulator with a normal airway. Subsequently, every participant performed one intubation attempt with each device in the same manikin with simulated cervical spine rigidity using a cervical collar. Glottic view, time until visualisation of the glottis and time until first ventilation were evaluated. Results Time until first ventilation was equivalent after three intubations in the first scenario. In the scenario with decreased cervical motion, the time until first ventilation was longer using the McGrath® compared to the GlideScope® and AMacintosh (p < 0.01). The success rate for endotracheal intubation was similar for all three devices. Glottic view was only improved using the McGrath® device (p < 0.001) compared to using the Macintosh blade. Conclusions The learning curve for video laryngoscopy in paramedics was steep in this study. However, these data do not support prehospital use of the McGrath® and GlideScope® devices by paramedics.
22 July 2009 in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
Background: The Bonfils intubation fibrescope is a promising alternative device for securing the airway. We examined the success rate of intubation and the ease of use in standardized simulated difficult airway scenarios by physicians. We compared the Bonfils to a classical laryngoscope with Macintosh blade. Methods: 30 physicians untrained in the use of rigid fibrescopes but experienced in airway management performed endotracheal intubation in an airway manikin (SimMan, Laerdal, Kent, UK) with three different airway conditions. We evaluated the success rate using the Bonfils (Karl Storz, Tuttlingen, Germany) or the Macintosh laryngoscope, the time needed for securing the airway, and subjective rating of both techniques. Results: In normal airway all intubations were successful using laryngoscope (100%) vs. 82% using the Bonfils (p < 0.05). In the scenario "tongue oedema" success rate using the Macintosh laryngoscope was 67% and 83% using the Bonfils. In the scenario "decreased cervical range of motion with jaw trismus", success rate using the Macintosh laryngoscope was 84% vs. 76%. In difficult airway scenarios time until airway was secured did not differ between the two devices. Use of Bonfils was rated "easier" in both difficult airway scenarios. Conclusion: The Bonfils can be successfully used by physicians unfamiliar with this technique in an airway manikin. The airway could be secured with at least the same success rate as using a Macintosh laryngoscope in difficult airway scenarios. Use of the Bonfils did not delay intubation in the presence of a difficult airway. These results indicate that intensive special training is advised to use the Bonfils effectively in airway management.
25 September 2009 in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
1 February 2016 in European Journal of Anaesthesiology