Michael I. Miga

Michael I. Miga

Auto-generated profile, based on publicly available information

Michael I. Miga

Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 1998 in Neurosurgery
Verified
Journal Article
Closed access
PDF file
DRDavid W. Roberts
David W. Roberts
AHAlexander Hartov
Alexander Hartov
FKFrancis E. Kennedy
Francis E. Kennedy
MMMichael I. Miga
Michael I. Miga
KPKeith D. Paulsen
Keith D. Paulsen
OBJECTIVE:. A quantitative analysis of intraoperative cortical shift and deformation was performed to gain a better understanding of the nature and ext

29 May 2013 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
TYThomas Yankeelov
Thomas Yankeelov
NANkiruka Atuegwu
Nkiruka Atuegwu
DIDavid A. Hormuth, II
David A. Hormuth, II
JWJared A. Weis
Jared A. Weis
SBStephanie L. Barnes
Stephanie L. Barnes
VQVito Quaranta
Vito Quaranta
Noninvasive imaging technologies can help create patient-specific mathematical models to predict tumor growth.

16 April 2001 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
EHElijah E.W. Van Houten
Elijah E.W. Van Houten
MMMichael I. Miga
Michael I. Miga
JWJohn B. Weaver
John B. Weaver
FKFrancis E. Kennedy
Francis E. Kennedy
KPKeith D. Paulsen
Keith D. Paulsen
Accurate characterization of harmonic tissue motion for realistic tissue geometries and property distributions requires knowledge of the full three‐dimensional displacement field because of the asymmetric nature of both the boundaries of the tissue domain and the location of internal mechanical heterogeneities. The implications of this for magnetic resonance elastography (MRE) are twofold. First, for MRE methods which require the measurement of a harmonic displacement field within the tissue region of interest, the presence of 3D motion effects reduces or eliminates the possibility that simpler, lower‐dimensional motion field images will capture the true dynamics of the entire stimulated tissue. Second, MRE techniques that exploit model‐based elastic property reconstruction methods will not be able to accurately match the observed displacements unless they are capable of accounting for 3D motion effects. These two factors are of key importance for MRE techniques based on linear elasticity models to reconstruct mechanical tissue property distributions in biological samples. This article demonstrates that 3D motion effects are present even in regular, symmetric phantom geometries and presents the development of a 3D reconstruction algorithm capable of discerning elastic property distributions in the presence of such effects. The algorithm allows for the accurate determination of tissue mechanical properties at resolutions equal to that of the MR displacement image in complex, asymmetric biological tissue geometries. Simulation studies in a realistic 3D breast geometry indicate that the process can accurately detect 1‐cm diameter hard inclusions with 2.5× elasticity contrast to the surrounding tissue. Magn Reson Med 45:827–837, 2001.

1 January 1999 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MMM.I. Miga
M.I. Miga
KPK.D. Paulsen
K.D. Paulsen
JLJ.M. Lemery
J.M. Lemery
SES.D. Eisner
S.D. Eisner
AHA. Hartov
A. Hartov
DRD.W. Roberts
D.W. Roberts
Image-guided neurosurgery relies on accurate registration of the patient, the preoperative image series, and the surgical instruments in the same coordinate space. Recent clinical reports have documented the magnitude of gravity-induced brain deformation in the operating room and suggest these levels of tissue motion may compromise the integrity of such systems. We are investigating a model-based strategy which exploits the wealth of readily-available preoperative information in conjunction with intraoperatively acquired data to construct and drive a three dimensional (3-D) computational model which estimates volumetric displacements in order to update the neuronavigational image set. Using model calculations, the preoperative image database can be deformed to generate a more accurate representation of the surgical focus during an operation. In this paper, we present a preliminary study of four patients that experienced substantial brain deformation from gravity and correlate cortical shift measurements with model predictions. Additionally, we illustrate our image deforming algorithm and demonstrate that preoperative image resolution is maintained. Results over the four cases show that the brain shifted, on average, 5.7 mm in the direction of gravity and that model predictions could reduce this misregistration error to an average of 1.2 mm.

15 November 2015 in Cancer Research
Verified
Journal Article
Closed access
PDF file
JWJared A. Weis
Jared A. Weis
MMMichael I. Miga
Michael I. Miga
LALori R. Arlinghaus
Lori R. Arlinghaus
XLXia Li
Xia Li
VAVandana Abramson
Vandana Abramson
TYThomas Yankeelov
Thomas Yankeelov
Although there are considerable data on the use of mathematical modeling to describe tumor growth and response to therapy, previous approaches are often not of the form that can be easily applied to clinical data to generate testable predictions in individual patients. Thus, there is a clear need to develop and apply clinically relevant oncologic models that are amenable to available patient data and yet retain the most salient features of response prediction. In this study we show how a biomechanical model of tumor growth can be initialized and constrained by serial patient-specific magnetic resonance imaging data, obtained at two time points early in the course of therapy (before initiation and following one cycle of therapy), to predict the response for individual patients with breast cancer undergoing neoadjuvant therapy. Using our mechanics coupled modeling approach, we are able to predict, after the first cycle of therapy, breast cancer patients that would eventually achieve a complete pathologic response and those who would not, with receiver operating characteristic area under the curve (AUC) of 0.87, sensitivity of 92%, and specificity of 84%. Our approach significantly outperformed the AUCs achieved by standard (i.e., not mechanically coupled) reaction–diffusion predictive modeling (0.75), simple analysis of the tumor cellularity estimated from imaging data (0.73), and the Response Evaluation Criteria in Solid Tumors (0.71). Thus, we show the potential for mathematical model prediction for use as a prognostic indicator of response to therapy. The work indicates the considerable promise of image-driven biophysical modeling for predictive frameworks within therapeutic applications. Cancer Res; 75(22); 4697–707. ©2015 AACR.

1 October 2013 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
DRD. Caleb Rucker
D. Caleb Rucker
JDJadav Das
Jadav Das
HGHunter B. Gilbert
Hunter B. Gilbert
PSPhilip J. Swaney
Philip J. Swaney
MMMichael I. Miga
Michael I. Miga
RWRobert J. Webster
Robert J. Webster
Steerable needles can potentially increase the accuracy of needle-based diagnosis and therapy delivery, provided they can be adequately controlled based on medical image information. We propose a novel sliding mode control law that can be used to deliver the tip of a flexible asymmetric-tipped needle to a desired point, or to track a desired trajectory within tissue. The proposed control strategy requires no a priori knowledge of model parameters, has bounded input speeds, and requires little computational resources. We show that if the standard nonholonomic model for tip-steered needles holds, then the control law will converge to desired targets in a reachable workspace, within a tolerance that can be defined by the control parameters. Experimental results validate the control law for target points and trajectory following in phantom tissue and ex vivo liver. Experiments with targets that move during insertion illustrate robustness to disturbances caused by tissue deformation.