Chunyang Zhang

Chunyang Zhang

Auto-generated profile, based on publicly available information

Chunyang Zhang

Department of Hematology, Myeloma & Lymphoma Center, Shanghai Changzheng Hospital, The Second Military Medical University, Shanghai, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2020 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
AJAaron Johnson
Aaron Johnson
SDShivam Desai
Shivam Desai
CZChunyang Zhang
Chunyang Zhang
KKKyung Koh
Kyung Koh
LZLi-Qun Zhang
Li-Qun Zhang
TMTheodore T. Manson
Theodore T. Manson
Background: Periprosthetic fracture is a leading reason for readmission following total hip arthroplasty. Most of these fractures occur during the early postoperative period before bone ingrowth. Before ingrowth occurs, the femoral component can rotate relative to the femoral canal, causing a spiral fracture pattern. We sought to evaluate, in a paired cadaver model, whether the torsional load to fracture was higher in collared stems. The hypothesis was that collared stems have greater load to fracture under axial and torsional loads compared with collarless stems. Methods: Twenty-two cadaveric femora (11 matched pairs) with a mean age of 77 ± 10.2 years (range, 54 to 90 years) were harvested. Following dissection, the femora were evaluated with use of a dual x-ray absorptiometry scanner and T scores were recorded. We utilized a common stem that is available with the same intraosseous geometry with and without a collar. For each pair, 1 femur was implanted with a collared stem and the contralateral femur was implanted with a collarless stem with use of a standard broaching technique. A compressive 68-kg load was applied to simulate body weight during ambulation. A rotational displacement was then applied until fracture occurred. Peak torque prior to fracture was measured with use of a torque meter load cell and data acquisition software. Results: The median torque to fracture was 65.4 Nm for collared stems and 43.1 Nm for uncollared stems (p = 0.0014, Wilcoxon signed-rank test). The median T score was –1.95 (range, –4.1 to –0.15). The median difference in torque to fracture was 29.18 Nm. As expected in each case, the mode of failure was a spiral fracture around the implant. Conclusions: Collared stems seemed to offer a protective effect in torsional loading in this biomechanical model comparing matched femora. Clinical Relevance: These results may translate into a protective effect against early periprosthetic Vancouver B2 femoral fractures that occur before osseous integration has occurred.

20 October 2020 in Leukemia
Verified
Journal Article
Open access
PDF file
JLJin Liu
Jin Liu
XHXiaoxia Hu
Xiaoxia Hu
YJYanchun Jia
Yanchun Jia
JLJin Lu
Jin Lu
JLJae Hoon Lee
Jae Hoon Lee
JDJuan Du
Juan Du
Immunoglobulin D (IgD) myeloma is a rare isotype that comprises 1-2% of multiple myeloma (MM) patients [1-3], which has significantly inferior survival for a median overall survival (OS) between 13 and 21 months [4-6]. Given the lack of large cohort with comprehensive clinical and cytogenetic assessment, knowledge about IgD myeloma is obtained mostly from a limited sample size [7]. Therefore, we carried out a multicenter retrospective study to evaluate the prevalence, clinical features, prognosis, and to develop and validate a prognostic model, including 356 patients with IgD myeloma from 14 centers of Asian Myeloma Network (AMN). Data were collected from China, Korea, and Singapore diagnosed from 2002 to 2019 (Supplementary Table 1). Ethical committee approvals were obtained and study protocol

29 May 2020 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
MRMatthew D. Riedel
Matthew D. Riedel
GOGiovanni Oppizzi
Giovanni Oppizzi
NONathan N. O'HAra
Nathan N. O'HAra
CZChunyang Zhang
Chunyang Zhang
KKKyung Koh
Kyung Koh
RORobert V. O'TOole
Robert V. O'TOole

1 September 2014
Verified
Open access
PDF file
XLXiangnan Li
Xiangnan Li
XPXue Pan
Xue Pan
CZChunyang Zhang
Chunyang Zhang
DZDengyan Zhu
Dengyan Zhu
JZJia Zhao
Jia Zhao
Video-assisted thoracoscopic sleeve lobectomy