Jonathan T. Bravman

Jonathan T. Bravman

Auto-generated profile, based on publicly available information

Jonathan T. Bravman

Department of Orthopedics, University of Colorado School of Medicine, Aurora, Colorado

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2017 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
MKMatthew J. Kraeutler
Matthew J. Kraeutler
KWK. Linnea Welton
K. Linnea Welton
EMEric C. McCarty
Eric C. McCarty
JBJonathan T. Bravman
Jonathan T. Bravman
➤ Technical errors such as nonanatomic tunnel placement are some of the most common causes of graft failure after primary anterior cruciate ligament reconstruction (ACLR). ➤ When considering a revision ACLR in a patient with ACL graft failure, it is crucial to perform preoperative imaging, which should include an initial radiographic series, magnetic resonance imaging, and possibly computed tomography for further assessment of tunnel locations. ➤ Revision ACLR may be performed in a 1 or 2-stage procedure depending on the size and location of the existing tunnels, bone stock, existing hardware, and infection status. ➤ Use of autograft ligament tissue for revision ACLR has been shown to correlate with higher patient-reported outcomes and a significantly lower risk of subsequent graft rupture in comparison with allograft use. ➤ Multiple studies have shown that the rate of return to the preinjury level of sport is significantly lower following revision ACLR than following primary ACLR procedures.

17 July 2021 in Arthroscopy, Sports Medicine, and Rehabilitation
Verified
Journal Article
Open access
ISIlona Schwarz
Ilona Schwarz
DHDarby A. Houck
Darby A. Houck
JBJohn W. Belk
John W. Belk
JHJack Hop
Jack Hop
JBJonathan T. Bravman
Jonathan T. Bravman
EMEric McCarty
Eric McCarty
Purpose: To evaluate the quality and content of internet‐based information available for some of the most common orthopaedic sports medicine terms. Methods: A search of the PubMed, Embase, and Cochrane databases following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta‐analyses) guidelines was performed. All English‐language literature published from 2010 to 2020 discussing information quality pertaining to orthopaedic sports medicine terms was included. Outcomes included the search engines used, number and type of websites evaluated, platform, and quality scoring metrics. Descriptive statistics are presented. Results: This review includes 21 studies. Of these, 3 evaluated both the upper and lower extremity. Twelve focused on either the upper or lower extremity, most commonly rotator cuff tears (3 of 12) and/or anterior cruciate ligament pathologies (7 of 12). The most common engines were Google (18 of 21), Bing (16 of 21), Yahoo (16 of 21), YouTube (3 of 21), Ask (3 of 21), and AOL (2 of 21). The average number of media files assessed per study was 87 ± 55. Website quality was assessed with DISCERN (7 of 21), Flesch‐Kincaid (9 of 21), Health on the Net (7 of 21), and/or Journal of the American Medical Association Benchmark (7 of 21) scores. YouTube was evaluated with Journal of the American Medical Association Benchmark scores (1.74 ± 1.00). Image quality was reported in 2 studies and varied with search terminology. Conclusions: The results of this systematic review suggest that physicians should improve the quality of online information and encourage patients to access credible sources when conducting their own research. Clinical Relevance: Doctors can and should play an active role in closing the gap between the level of health literacy of their patients and that of most common online resources.

1 May 2020 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
JBJohn W. Belk
John W. Belk
MKMatthew J. Kraeutler
Matthew J. Kraeutler
JSJohn R. Smith
John R. Smith
CLConnor P. Littlefield
Connor P. Littlefield
JBJonathan T. Bravman
Jonathan T. Bravman
EMEric C. McCarty
Eric C. McCarty

1 May 2015 in Orthopedics
Verified
Journal Article
Closed access
PDF file
JBJonathan T. Bravman
Jonathan T. Bravman
MTMichal L. Taylor
Michal L. Taylor
TBTodd Baldini
Todd Baldini
AVArmando F. Vidal
Armando F. Vidal
Higher rates of poor outcomes in displaced midshaft clavicle fractures treated nonoperatively have recently been reported. Along with expanding indications for operative fixation and increasing application of locked plate constructs, it is unknown whether complications related to bicortical penetration of the clavicle can be avoided using unicortical fixation. The purpose of this study is to compare the biomechanical properties of unicortical and bicortical fixation in precontoured vs manually contoured locking clavicle plates. Forty-eight Sawbone composite human clavicle specimens (item #3408; Pacific Research Laboratories, Vashon, Washington) with a midshaft clavicle osteotomy were reduced and plated in 8 specimens each using a bicortical and unicortical fixation for each of 3 locked plate constructs (3.5-mm LCP Reconstruction Plate; 3.5-mm LCP Superior Clavicle Plate; 3.5-mm LCP Superior Anterior Clavicle Plate; Synthes, Inc, West Chester, Pennsylvania). Specimens were tested for stiffness in axial torsion and cantilever bending and then loaded to failure in 3-point bending. Data were analyzed using 2-way analysis of variance and Tukey’s test ( P <.05). No significant differences were found between unicortical and bicortical fixation in failure load, cantilever bending, and cross body stiffness. Bicortical fixation was significantly stiffer than unicortical fixation in torsion only for the same plates. Significant differences also existed between plates in torsion. Unicortical locked plate fixation may be a reasonable option in the treatment of displaced midshaft clavicle fracture fixation to avoid complications associated with posteroinferior hardware penetration following clavicle fracture fixation based on the biomechanical performance of these constructs. However, it remains unclear whether these differences will be clinically significant. [ Orthopedics. 2015; 38(5):e411–e416.]

1 December 2009 in Orthopedics
Verified
Journal Article
Closed access
JBJonathan T. Bravman
Jonathan T. Bravman
AVArmando F. Vidal
Armando F. Vidal
Orthopedics | Clavicle fractures are common injuries, comprising approximately 40% of fractures about the shoulder and between 5% to 12% of all fractures overall. With a reported incidence of 20 to 50 per 100,000 patients per year, an estimated >100,000 of these injuries occur annually in the United states alone.1,2 Despite centuries of documented clinical experience with the treatment of these injuries,

1 September 2017 in Orthopaedic Journal of Sports Medicine
Verified
Journal Article
Open access
JSJohn B. Schrock
John B. Schrock
MKMatthew J. Kraeutler
Matthew J. Kraeutler
JBJonathan T. Bravman
Jonathan T. Bravman
A number of techniques are available for performing biceps tenodesis, the majority of which result in good or excellent outcomes. However, failure may result in pain and/or dissatisfying biceps deformity. To compare the clinical failure rates of 2 methods of suture passage in subpectoral biceps tenodesis with suture anchors performed by the senior author. Cohort study; Level of evidence, 3. A retrospective chart review was conducted of patients who underwent biceps tenodesis under the care of the senior author. Operative notes were used to determine whether the procedure was performed with a BirdBeak (BB) suture passer or a free needle (FN). Each subsequent clinical follow-up note was used to determine participation in physical therapy and duration, follow-up duration, and whether clinical tenodesis failure had occurred. Biceps tenodesis failure was defined as either cosmetic deformity (“Popeye” sign), pain at the tenodesis site, or need for revision. Overall, 163 patients met the inclusion criteria (BB, n = 112; FN, n = 51). Mean follow-up was 5.3 months and 4.1 months in the BB and FN groups, respectively. Significantly more tenodesis failures occurred in the BB group (BB, 12%; FN, 2%, P = .042). Among all BB patients, 10% experienced failure due to cosmetic deformity, 2% required revision, and 4% had postoperative pain at the tenodesis site by latest follow-up. The 1 patient in the FN group who experienced failure presented with cosmetic deformity postoperatively. Biceps tenodesis with the use of an FN to pass the suture resulted in a significantly lower clinical failure rate compared with the use of a BB suture passer.