Prakash Kumar Hota

Prakash Kumar Hota

Auto-generated profile, based on publicly available information

Prakash Kumar Hota

Department of Electrical Engineering, Veer Surendra Sai University of Technology, Burla, Odisha, India

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
BMBanaja Mohanty
Banaja Mohanty
SPSidhartha Panda
Sidhartha Panda
PHP.K. Hota
P.K. Hota

1 December 2013 in Applied Soft Computing
Verified
Journal Article
Closed access
SPSidhartha Panda
Sidhartha Panda
BMBanaja Mohanty
Banaja Mohanty
PHP.K. Hota
P.K. Hota

1 September 2010 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
PHP.K. Hota
P.K. Hota
ABA.K. Barisal
A.K. Barisal
RCR. Chakrabarti
R. Chakrabarti

1 July 2009 in Electric Power Systems Research
Verified
Journal Article
Closed access
PHP.K. Hota
P.K. Hota
ABA.K. Barisal
A.K. Barisal
RCR. Chakrabarti
R. Chakrabarti

1 September 2014 in Alexandria Engineering Journal
Verified
Journal Article
Open access
BMBanaja Mohanty
Banaja Mohanty
SPSidhartha Panda
Sidhartha Panda
PHP.K. Hota
P.K. Hota
This paper presents the design and performance analysis of Differential Evolution (DE) algorithm based Proportional–Integral (PI) and Proportional–Integral–Derivative (PID) controllers for Automatic Generation Control (AGC) of an interconnected power system. Initially, a two area thermal system with governor dead-band nonlinearity is considered for the design and analysis purpose. In the proposed approach, the design problem is formulated as an optimization problem control and DE is employed to search for optimal controller parameters. Three different objective functions are used for the design purpose. The superiority of the proposed approach has been shown by comparing the results with a recently published Craziness based Particle Swarm Optimization (CPSO) technique for the same interconnected power system. It is noticed that, the dynamic performance of DE optimized PI controller is better than CPSO optimized PI controllers. Additionally, controller parameters are tuned at different loading conditions so that an adaptive gain scheduling control strategy can be employed. The study is further extended to a more realistic network of two-area six unit system with different power generating units such as thermal, hydro, wind and diesel generating units considering boiler dynamics for thermal plants, Generation Rate Constraint (GRC) and Governor Dead Band (GDB) non-linearity

1 March 2011 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
RSR.K. Swain
R.K. Swain
ABA.K. Barisal
A.K. Barisal
PHP.K. Hota
P.K. Hota
RCR. Chakrabarti
R. Chakrabarti