Robert Hitchcock

Robert Hitchcock

Auto-generated profile, based on publicly available information

Robert Hitchcock

Department of Bioengineering University of Utah Salt Lake City UT USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Urogynecology
Verified
Journal Article
Open access
JGJohanna Day de Gennaro
Johanna Day de Gennaro
CGClaire K. de Gennaro
Claire K. de Gennaro
JSJanet M. Shaw
Janet M. Shaw
TPTomasz J. Petelenz
Tomasz J. Petelenz
INIngrid E. Nygaard
Ingrid E. Nygaard
RHRobert W. Hitchcock
Robert W. Hitchcock
Objectives: High intra-abdominal pressure (IAP) may influence the development of pelvic floor disorders. We and others have used intravaginal pressure transducers to measure IAP in women during exercise and daily activities, but utilizing the transducer for long-term measurements creates compliance issues. Waist-worn accelerometers are prominent in research and may be a reliable alternative for approximating IAP. We hypothesized that there are pair-wise positive correlations between the mean maximal accelerometer vector magnitude and 2 IAP measurements: mean maximal IAP and area under the curve (AUC). Methods: Twenty-five women who regularly participated in exercise performed 13 activities. Intra-abdominal pressure was measured with an intravaginal transducer and acceleration with a waist-worn accelerometer. We determined the mean maximal IAP, AUC for IAP, and mean maximal accelerometer vector magnitude for each activity and participant. The relationship between IAP and acceleration was determined by computing the Pearson correlation coefficient (R) and the 95% confidence interval for mean maximal accelerometer vector magnitude versus mean maximal IAP and mean maximal accelerometer vector magnitude versus AUC for IAP. Results: The R values were 0.7353 for mean maximal accelerometer vector magnitude versus mean maximal IAP (including walking) and 0.5059 for mean maximal accelerometer vector magnitude versus AUC for IAP (excluding walking). Walking at 3 speeds, analyzed separately, presented R values of 0.72208 for mean maximal IAP and 0.21678 for AUC. Conclusion: Waist-worn accelerometers may provide a viable method for approximating mean maximal IAP in a population of women during most activities.

1 May 2019 in Gait & Posture
Verified
Journal Article
Closed access
ALArad Lajevardi-Khosh
Arad Lajevardi-Khosh
SBStacy Bamberg
Stacy Bamberg
DRDavid L Rothberg
David L Rothberg
EKErik Kubiak
Erik Kubiak
TPTomasz Petelenz
Tomasz Petelenz
RHRobert Hitchcock
Robert Hitchcock

1 August 2020 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
AKAditya K Kaza
Aditya K Kaza
AMAbhijit Mondal
Abhijit Mondal
BPBreanna Piekarski
Breanna Piekarski
FSFrank B. Sachse
Frank B. Sachse
RHRobert Hitchcock
Robert Hitchcock
The aim of this study was to evaluate the feasibility and safety of fibre-optic confocal microscopy (FCM) using fluorescein sodium dye for the intraoperative location of conduction tissue regions during paediatric heart surgery. The pilot study included 6 patients undergoing elective surgery for the closure of isolated secundum atrial septal defect aged 30 days to 21 years. FCM imaging was integrated within the normal intraoperative protocol for atrial septal defect repair. Fluorescein sodium dye was applied on the arrested heart. FCM images were acquired at the atrioventricular node region, sinus node region and right ventricle (RV). Total imaging time was limited to 3 min. Any adverse events related to the study were recorded and analysed. Subjects received standard postoperative care. Trained reviewers (n = 9) classified, de-identified and randomized FCM images (n = 60) recorded from the patients as presenting striated, reticulated or indistinguishable microstructures. The reliability of reviewer agreement was assessed using Fleiss’ kappa. The FCM imaging instruments were integrated effectively into the cardiac surgery operating room. All adverse events found in the study were deemed expected and not related to FCM imaging. Reticulated myocardial microstructures were found during FCM imaging at atrioventricular node and sinus node regions, while striated microstructures were observed in RV. Reliability of agreement of reviewers classifying the FCM images was high (Fleiss’ kappa: 0.822). FCM using fluorescein sodium dye was found to be safe for use during paediatric heart surgery. The study demonstrates the potential for FCM to be effective in identifying conduction tissue regions during congenital heart surgery. NCT03189134.


30 June 2025 in BJU International
Verified
Journal Article
Open access
MBMarie‐Eve Berube
Marie‐Eve Berube
SNStefan Niederauer
Stefan Niederauer
RGRyan Graham
Ryan Graham
RHRobert Hitchcock
Robert Hitchcock
LMLinda McLean
Linda McLean
Objectives: To investigate whether, among female runners, transient changes in pelvic floor morphometry, pelvic floor muscle (PFM) function, or pad weight gain observed after a standardised running protocol are associated with the exposure of the pelvic floor to loading during the run. Methods: Adult female runners with ( n = 19) and without ( n = 19) running‐induced stress urinary incontinence (RI‐SUI) completed a 37‐min treadmill‐based running protocol with a pressure sensor placed in the posterior fornix of the vagina and a triaxial accelerometer adhered to the pelvis, and an incontinence pad adhered to their undergarment. Pelvic morphometry and PFM function were assessed before and after the run using transperineal ultrasonography and intra‐vaginal dynamometry. Urine leakage volume was estimated based on incontinence pad weight gain. Separate linear regression models were used to evaluate the associations between variables representative of pelvic floor load exposure (posterior fornix sensor pressure [PFSP] and pelvic accelerations) and changes in pelvic morphometry, PFM function, and incontinence pad weight observed after the run. Results: After the run, the levator hiatus was larger and the bladder neck sat lower in the pelvis, but there were no significant differences in PFM active or passive forces measured using dynamometry. These changes were not different between those with and those without RI‐SUI. Higher pelvic accelerations were associated with greater reductions in passive PFM stiffness after the run ( R 2 = 20%–27%), but not with changes in pelvic morphometry. No associations were found between any measures of pelvic floor load exposure and changes in PFM force‐generating capacity. Among runners with RI‐SUI, greater pad weight gain occurred among those who ran with slower vector accelerations ( R 2 = 0.27). Conclusion: The magnitude of pelvic floor loading experienced during running does not appear to influence the transient loss in static pelvic organ support observed after running nor urine leakage volume.