Changyun Yang

Changyun Yang

Auto-generated profile, based on publicly available information

Changyun Yang

College of Energy and Mining Engineering, Shandong University of Science and Technology 1 , Qingdao 266590

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2025 in Journal of Applied Physics
Verified
Journal Article
Open access
BZBangzhi Zhang
Bangzhi Zhang
XZXilong Zhou
Xilong Zhou
CYChangyun Yang
Changyun Yang
V-shaped microcantilevers exhibit high sensitivity and low stiffness characteristics, making them suitable for use as atomic force microscopy probes that enable high-resolution surface imaging and nanomechanical characterization of soft biological samples in liquid environments. However, due to the complex geometry of the V-shaped microcantilever and the effects of fluid–structure coupling and nonlinear tip–sample interactions when operating in liquids, it is generally difficult to study its dynamic characteristics analytically. This study establishes a computational framework based on the finite difference method (FDM) to analyze the dynamic response of a V-shaped microcantilever in liquids by equivalently modeling fluid effects as added mass and damping. The resonance frequencies and the time-varying displacement of the V-shaped microcantilever are calculated and compared with those obtained by the finite element method to validate the accuracy and efficiency of FDM. The effects of the cantilever–sample separation, the free amplitude, and the sample modulus on the dynamic responses of the V-shaped microcantilever are further analyzed. Results demonstrate that nonlinear tip–sample interactions excite higher harmonics, amplified by internal resonance of higher modes. Reducing free amplitude or employing phase imaging enhances measurement sensitivity in liquids. This method offers a computationally efficient tool for dynamic analysis and structural optimization of V-shaped microcantilevers in fluid environments.

10 November 2025 in Journal of Applied Physics
Verified
Journal Article
Open access
CYChangyun Yang
Changyun Yang
XZXilong Zhou
Xilong Zhou
BZBangzhi Zhang
Bangzhi Zhang
The dynamic behavior of the microcantilever in torsional resonance atomic force microscopy (TR-AFM) operating in liquid environments is governed by a complex interplay between hydrodynamic loading and tip–sample interactions, posing challenges for the quantitative analysis of its dynamic characteristics. To address this issue, this study establishes a fluid–structure interaction model by incorporating equivalent hydrodynamic added mass and added damping. Dimensionless expressions for these parameters are derived through dimensional analysis, and their quantitative correlations are fitted via fluid–structure interaction simulations. The fitted expressions for these parameters enable a systematic investigation of the microcantilever's torsional vibration characteristics in liquids. Results show that the torsional resonance frequency in liquids is primarily governed by fluid density, while the vibration amplitude is dominantly influenced by fluid viscosity. Furthermore, the analysis of tip–sample contacts reveals that the torsional contact resonance frequency is predominantly governed by the sample shear modulus, while the vibration amplitude is significantly influenced by both the sample shear modulus and contact damping. The developed framework provides an essential approach for the quantitative characterization of sample shearing properties using TR-AFM in liquids.

1 June 2025 in AIP Advances
Verified
Journal Article
Open access
BZBangzhi Zhang
Bangzhi Zhang
CYChangyun Yang
Changyun Yang
XZXilong Zhou
Xilong Zhou
V-shaped microcantilevers have advantages in dynamic atomic force microscopy (AFM) imaging, such as increased stability or decreased sample damage. However, for higher harmonic or multi-frequency imaging, the regulation of the frequency ratio between higher-mode resonance frequency and fundamental frequency is impeded for lacking a quantitative relationship between the frequency ratio and geometric parameters. In this work, a function model relating the frequency ratio to the dimensionless geometric parameters of V-shaped microcantilevers is obtained based on dimensional analysis. The finite difference method is employed to solve the vibrational equation, demonstrating that the frequency ratio is primarily governed by the normalized free-end width and leg width, but thickness and length ratios have negligible influence. A set of data incorporating frequency ratios under various geometric parameters is created and fitted into a two-variable function model. By adjusting the frequency ratio to specific integer multiples, optimized designs have been demonstrated to enhance higher harmonic amplitudes by up to 103.3%. This work provides a framework for optimizing V-shaped microcantilevers, enabling high-sensitivity, multi-frequency AFM imaging.