Joshua J. Coon

Joshua J. Coon

Auto-generated profile, based on publicly available information

Joshua J. Coon

Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2012 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
PDF file
APAmelia C. Peterson
Amelia C. Peterson
JRJason D. Russell
Jason D. Russell
DBDerek J. Bailey
Derek J. Bailey
MWMichael S. Westphall
Michael S. Westphall
JCJoshua J. Coon
Joshua J. Coon
Selected reaction monitoring on a triple quadrupole mass spectrometer is currently experiencing a renaissance within the proteomics community for its, as yet, unparalleled ability to characterize and quantify a set of proteins reproducibly, completely, and with high sensitivity. Given the immense benefit that high resolution and accurate mass instruments have brought to the discovery proteomics field, we wondered if highly accurate mass measurement capabilities could be leveraged to provide benefits in the targeted proteomics domain as well. Here, we propose a new targeted proteomics paradigm centered on the use of next generation, quadrupole-equipped high resolution and accurate mass instruments: parallel reaction monitoring (PRM). In PRM, the third quadrupole of a triple quadrupole is substituted with a high resolution and accurate mass mass analyzer to permit the parallel detection of all target product ions in one, concerted high resolution mass analysis. We detail the analytical performance of the PRM method, using a quadrupole-equipped bench-top Orbitrap MS, and draw a performance comparison to selected reaction monitoring in terms of run-to-run reproducibility, dynamic range, and measurement accuracy. In addition to requiring minimal upfront method development and facilitating automated data analysis, PRM yielded quantitative data over a wider dynamic range than selected reaction monitoring in the presence of a yeast background matrix because of PRM9s high selectivity in the mass-to-charge domain. With achievable linearity over the quantifiable dynamic range found to be statistically equal between the two methods, our investigation suggests that PRM will be a promising new addition to the quantitative proteomics toolbox.

1 January 2021 in Cell Systems
Verified
Journal Article
Open access
KOKatherine A. Overmyer
Katherine A. Overmyer
ESEvgenia Shishkova
Evgenia Shishkova
IMIan J. Miller
Ian J. Miller
JBJoseph Balnis
Joseph Balnis
MBMatthew N. Bernstein
Matthew N. Bernstein
AJAriel Jaitovich
Ariel Jaitovich
We performed RNA-seq and high-resolution mass spectrometry on 128 blood samples from COVID-19-positive and COVID-19-negative patients with diverse disease severities and outcomes. Quantified transcripts, proteins, metabolites, and lipids were associated with clinical outcomes in a curated relational database, uniquely enabling systems analysis and cross-ome correlations to molecules and patient prognoses. We mapped 219 molecular features with high significance to COVID-19 status and severity, many of which were involved in complement activation, dysregulated lipid transport, and neutrophil activation. We identified sets of covarying molecules, e.g., protein gelsolin and metabolite citrate or plasmalogens and apolipoproteins, offering pathophysiological insights and therapeutic suggestions. The observed dysregulation of platelet function, blood coagulation, acute phase response, and endotheliopathy further illuminated the unique COVID-19 phenotype. We present a web-based tool (covid-omics.app) enabling interactive exploration of our compendium and illustrate its utility through a machine learning approach for prediction of COVID-19 severity.

1 January 2014 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
PDF file
AHAlexander S. Hebert
Alexander S. Hebert
ARAlicia L. Richards
Alicia L. Richards
DBDerek J. Bailey
Derek J. Bailey
AUArne Ulbrich
Arne Ulbrich
ECEmma E. Coughlin
Emma E. Coughlin
JCJoshua J. Coon
Joshua J. Coon
We describe the comprehensive analysis of the yeast proteome in just over one hour of optimized analysis. We achieve this expedited proteome characterization with improved sample preparation, chromatographic separations, and by using a new Orbitrap hybrid mass spectrometer equipped with a mass filter, a collision cell, a high-field Orbitrap analyzer, and, finally, a dual cell linear ion trap analyzer (Q-OT-qIT, Orbitrap Fusion). This system offers high MS2 acquisition speed of 20 Hz and detects up to 19 peptide sequences within a single second of operation. Over a 1.3 h chromatographic method, the Q-OT-qIT hybrid collected an average of 13,447 MS1 and 80,460 MS2 scans (per run) to produce 43,400 (x̄) peptide spectral matches and 34,255 (x̄) peptides with unique amino acid sequences (1% false discovery rate (FDR)). On average, each one hour analysis achieved detection of 3,977 proteins (1% FDR). We conclude that further improvements in mass spectrometer scan rate could render comprehensive analysis of the human proteome within a few hours.

29 January 2010 in Journal of Proteome Research
Verified
Journal Article
Closed access
DSDanielle L. Swaney
Danielle L. Swaney
CWCraig D. Wenger
Craig D. Wenger
JCJoshua J. Coon
Joshua J. Coon

8 December 2006 in Analytical Chemistry
Verified
Journal Article
Closed access
DSDanielle L. Swaney
Danielle L. Swaney
GMGraeme C. McAlister
Graeme C. McAlister
MWMatthew Wirtala
Matthew Wirtala
JSJae C. Schwartz
Jae C. Schwartz
JSJohn E. P. Syka
John E. P. Syka
JCJoshua J. Coon
Joshua J. Coon

3 July 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
AHAlexander S. Hebert
Alexander S. Hebert
SPSatendra Prasad
Satendra Prasad
MBMichael W. Belford
Michael W. Belford
DBDerek J. Bailey
Derek J. Bailey
GMGraeme C. McAlister
Graeme C. McAlister
JCJoshua J. Coon
Joshua J. Coon