Yawei Wei

Yawei Wei

Auto-generated profile, based on publicly available information

Yawei Wei

Real-Time Power and Intelligent Systems Laboratory, The Holcombe Department of Electrical and Computer Engineering, Clemson University, Clemson, SC, 29634, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2019 in IET Smart Grid
Verified
Journal Article
Open access
PDF file
YWYawei Wei
Yawei Wei
IJIroshani Jayawardene
Iroshani Jayawardene
GVGanesh Kumar Venayagamoorthy
Ganesh Kumar Venayagamoorthy
The centralised utility‐scale photovoltaic (PV) plants installation has greatly enlarged their percentage in the bulk power systems, along with the nature uncertainty for the balance of system power and loads. Consequently, the successful integration of solar PV power in large‐scale power systems requires a reliable and efficient multi‐area automatic generation control (AGC) system within the control centre. Specifically, area‐AGCs that perform tie‐line bias control, in which the area frequency regulates the tie‐line power flow, must balance the operational control area supply power‐and‐demand loads within a pre‐tuned parameter set. Traditional AGC control systems have area linear controllers that must be periodically tuned to manage the high fluctuation of PV power. A practical two‐step tuning method to determine the optimal parameters of existing multi‐area AGCs is presented. The proposed method is demonstrated on a five‐area multi‐machine power system with two large PV plants. The power system was equipped with the synchrophasor‐based monitoring system, with a real‐time simulation platform serving as the application host. Results indicated that the two‐step tuning method provides optimal parameters for all the system AGCs over a wide range of PV penetration levels. Typical results demonstrated the effectiveness of the tuned multi‐area AGCs under dynamic conditions and disturbances.

1 July 2019 in Electric Power Systems Research
Verified
Journal Article
Closed access
YWYawei Wei
Yawei Wei
PAParanietharan Arunagirinathan
Paranietharan Arunagirinathan
Ali ArzaniAli Arzani
Ali Arzani
GVGanesh Kumar Venayagamoorthy
Ganesh Kumar Venayagamoorthy

1 September 2017 in Neural Networks
Verified
Journal Article
Closed access
YWYawei Wei
Yawei Wei
GVGanesh Kumar Venayagamoorthy
Ganesh Kumar Venayagamoorthy

1 November 2017
Verified
Conference Paper
Closed access
IJIroshani Jayawardene
Iroshani Jayawardene
YWYawei Wei
Yawei Wei
GVGanesh Kumar Venayagamoorthy
Ganesh Kumar Venayagamoorthy
An unexpected load change in an interconnected multi-area power system can cause variations in area frequencies and tie-line power flows of the system. Integration of renewable energy sources increases the uncertainties in a power system, which causes more frequency and tie-line power variabilities. Automatic generation control (AGC) plays a vital role in multi-area power systems in maintaining area frequencies and tie-line power flows at their nominal values while utilizing available renewable energy. An effective AGC requires optimal selection of its parameters for best tie-line bias control. In this study, a particle swarm optimization (PSO) approach is presented for tuning parameters of AGCs in a multi-area power system with photovoltaic plants. A modified IEEE New-England and NewYork test model with five AGCs is simulated on a real-time digital simulator. Typical results indicate that PSO based AGC parameters provide minimal area control errors with improved system performance.

3 November 2016
Verified
Conference Paper
Closed access
YWYawei Wei
Yawei Wei
GVGanesh Kumar Venayagamoorthy
Ganesh Kumar Venayagamoorthy
Power system protection and emergency control systems require continuous monitoring to prevent grid-wide frequency instability or system islanding. Amongst different methods, cellular computation networks (CCNs) are more suitable for providing dynamic frequency predictions. CCN is a scalable and distributed framework using the concept of cells and intercellular connections to represent a power system topology with multiple synchronous machines, transmission lines and loads. However, from a practical viewpoint, fast computing algorithms are needed for effective monitoring and response. In this paper, a lite CCN is proposed based on generalized neurons (GNs), referred to as the cellular generalized neuron network (CGNN). The performance of CGNN is compared with that of a cellular multilayer perceptron network (CMLPN). The frequency predictions by the CGNN and CMLPN have been validated on a two-area four-machine benchmark power system. Data for the CGNN is provided from a real time digital simulation of the power system with phasor measurement units (PMUs). Based on a performance metric, results obtained show that the CGNN outperforms the CMLPN, especially in terms of least number of trainable parameters, low training time and better prediction accuracy.

1 September 2018
Verified
Conference Paper
Closed access
PAParanietharan Arunagirinathan
Paranietharan Arunagirinathan
YWYawei Wei
Yawei Wei
Ali ArzaniAli Arzani
Ali Arzani
GVGanesh Kumar Venayagamoorthy
Ganesh Kumar Venayagamoorthy
Historically, poorly damped electromechanical oscillations exhibited by synchronous generators have caused power system blackouts. With variable generation sources such as PV power integrated in power systems, the high variability and lack of sufficiently accurate forecasts, triggers electromechanical oscillations. Optimally tuned power system stabilizers (PSSs) are expected to provide effective damping to these electromechanical oscillations. The effects of the variations of the PV power and system disturbances on the speed deviations of the generators are captured and used in the formulation of the cost function to be optimized. The IEEE 68 bus 16 generator benchmark New England-New York power system integrated with utility scale PV generation sources is studied.