José Fernando Márquez Pachas

José Fernando Márquez Pachas

Auto-generated profile, based on publicly available information

José Fernando Márquez Pachas

Facultad de Ciencias Físicas

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2026 in Revista Mexicana de Física
Verified
Journal Article
Open access
PDF file
CGCecilia Querebalu Garcia
Cecilia Querebalu Garcia
POPaul Elias Panizo Olivos
Paul Elias Panizo Olivos
EMEduardo Garnique Millones
Eduardo Garnique Millones
CMChristian Heyrner Barragan Mondragon
Christian Heyrner Barragan Mondragon
JPJosé Fernando Márquez Pachas
José Fernando Márquez Pachas
ESEduardo Becquer Carrasco Solis
Eduardo Becquer Carrasco Solis
Radiation exposure in mammography can vary considerably across centers, potentially affecting both diagnostic quality and patient safety. In Trujillo, Peru, no locally adjusted absorbed dose values were previously available. Therefore, the objective of this study was to establish local diagnostic reference levels (LDRLs) for digital mammography within the EsSalud hospital network (Social Health Insurance) in Trujillo. A retrospective, multicenter study was conducted in three hospitals, analyzing 133 digital mammograms acquired with Hologic Selenia Dimensions systems. Technical parameters such as kilovoltage, tube load, compression force, compressed breast thickness, and average glandular dose (AGD) were collected and processed using automated systems. The LDRLs, defined as the 75th percentile of the AGD distribution, were determined for the craniocaudal (CC) and mediolateral oblique (MLO) projections. Multiple linear regression analysis was performed to identify independent predictors of AGD. The proposed LDRLs were 1.78 mGy for CC and 2.12 mGy for MLO, values well below the reference level of 3 mGy recommended by the Basic Safety Standards of the International Atomic Energy Agency (IAEA), and 30 − 39% lower than the regional LDRLs previously reported for direct digital radiography (DDR) systems in Latin America. Tube load (β = 0.886, p < 0.001 for CC; β = 0.572, p < 0.001 for MLO) and compressed breast thickness (β = 0.193, p < 0.001 for CC; β = 0.297, p = 0.001 for MLO) were identified as the most significant technical predictors of AGD. The established LDRLs demonstrate optimized dosimetric practices within the EsSalud network in Trujillo, ensuring that patient doses are appropriate, consistent, and aligned with international standards. Their implementation will facilitate ongoing dose monitoring, protocol standardization, and the strengthening of radiation protection in breast cancer screening programs.

28 May 2025 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
GTGabriela Corati Touguinha
Gabriela Corati Touguinha
AGAlberto E Gonzales-Ccoscco
Alberto E Gonzales-Ccoscco
LSLeonardo Pessoa da Silva
Leonardo Pessoa da Silva
HTHenrique Trombini
Henrique Trombini
HBHeitor Ribeiro Birnfeld
Heitor Ribeiro Birnfeld
MAMirko Salomón Alva-Sánchez
Mirko Salomón Alva-Sánchez
Purpose. To evaluate and compare the dosimetric properties of various materials used in intraoral stents, with a particular focus on their interaction with a 6 MV photon beam in head and neck cancer radiotherapy. Materials and Methods. Experimental irradiation and computational simulation methods were employed to analyze the interaction of various materials with a 6 MV photon beam used in an intraoral procedure. A head phantom, cylindrical in shape and divided into 1 cm plates, was used along with circular PMMA plates and polystyrene to simulate an intraoral procedure. Radiochromic film (EBT3) was used to evaluate the dose–response of PMMA and PET-G materials with thicknesses of 1, 2, and 3 mm, irradiated under a 10 × 10 cm2 field size at a 100 cm source-to-skin distance (SSD). The PENELOPE code was used to simulate the dosimetric properties of PMMA, PET-G, EVA, PDMS, and PVDF based on their chemical compositions. Results. A maximum divergence of 4.2% was observed between PET-G and PMMA at a thickness of 3 mm during the experimental procedure. Additionally, a maximum difference of 1.2% was noted when comparing the simulated percentage depth dose curves. Discrepancies of up to 10% were found between experimental irradiation and simulations in polystyrene regions, likely due to the sensitivity of the film to incident fluence. When comparing the simulated materials (PMMA, PET-G, EVA, PDMS, and PVDF), the largest divergence observed was 20% at the surface of the phantom and did not exceed 15% at depths under 10 cm, specifically between PVDF and PMMA. For all other materials, the divergence remained below 10% across all regions. Conclusions. The results suggest that all the materials evaluated for intraoral stent fabrication can be effectively analyzed using the simulation code. PET-G, EVA, and PDMS showed dose–response variations of less than 10%, which should be considered when calculating doses in the treatment system planning, as stents made from these materials may increase the dose to nearby organs.

30 June 2022 in TECNIA
Verified
Journal Article
Open access
PDF file
ÁHÁngel Rodríguez Horna
Ángel Rodríguez Horna
CCCarmen Sandra Guzman Calcina
Carmen Sandra Guzman Calcina
MZModesto Montoya Zavaleta
Modesto Montoya Zavaleta
JPJosé Fernando Márquez Pachas
José Fernando Márquez Pachas
JAJesús Aymar Alejos
Jesús Aymar Alejos
JHJessenia Brillit Villaverde Herrera
Jessenia Brillit Villaverde Herrera
Objetivo: Implementar un Sistema Postal de Control de Calidad para verificar el Sistema de Planificación de Tratamiento en Teleterapia usando dosímetros Al2O3 :C, basados en la tecnología de luminiscencia ópticamente estimulada (OSL-Optically Stimulated Luminescence), comercialmente conocidos como OSLD nanoDotTM. Materiales y Métodos: Se utilizó un maniquí que contiene dosímetros OSLD nanoDotTM, (Al2O3 :C), previamente caracterizados y calibrados para la energía de un haz de rayos x de 6.0 MV generados en un acelerador lineal, los valores de dosis absorbida fueron medidos con: una cámara de ionización Semiflex, electrómetro PTW – Freigburg, geometrías 3D de radiación, tales como: Geometría simple (campo abierto a 0º y 25º), Geometría compleja (tres campos abiertos a 0º, 90º y 270º) y Geometría combinada (campo y diversas variaciones de giro de Gantry), utilizando campos cuadrados (6cm2), circulares (diámetro 6cm), oblicuos (6cm x 6cm) e Irregulares, pesos iguales y filtros de cuña virtual en diferentes regiones del haz de fotones. Resultados: Los valores de la caracterización de los OSLD nanodot fueron: homogeneidad (0.9999), por desvanecimiento en el tiempo (0.9989), por corrección de agotamiento (0.9985), de reproducibilidad (0.9953), por dependencia angular (0.9925) y por linealidad (1.0000) para un rango de dosis absorbida 100cGy a 200cGy. Las evaluaciones en las diferentes regiones del haz, en medio homogéneo, fueron las siguientes: Geometría simple (Incertidumbre: 3.01%), Geometría compleja (Incertidumbre: 2.16%) y Geometría Combinada (Incertidumbre: 2.62%) Conclusiones: Los resultados obtenidos se encuentran dentro de los valores de tolerancia, concluyendo que así el OSLD nanoDot TM es un dosímetro altamente confiable, además de su conveniencia en su integración en un programa de auditoria dosimétrica postal.

5 September 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
SLS Leon
S Leon
OPO Paucar
O Paucar
NCN Correa
N Correa
MGM Glassell
M Glassell
AGA Gonzales
A Gonzales
DRD Roa
D Roa
Objective. The goal of this study was to use Monte Carlo (MC) simulations and measurements to investigate the dosimetric suitability of an interventional radiology (IR) c-arm fluoroscope to deliver low-dose radiotherapy to the lungs. Approach. A previously-validated MC model of an IR fluoroscope was used to calculate the dose distributions in a COVID-19-infected patient, 20 non-infected patients of varying sizes, and a postmortem subject. Dose distributions for PA, AP/PA, 3-field and 4-field treatments irradiating 95% of the lungs to a 0.5 Gy dose were calculated. An algorithm was created to calculate skin entrance dose as a function of patient thickness for treatment planning purposes. Treatments were experimentally validated in a postmortem subject by using implanted dosimeters to capture organ doses. Main results. Mean doses to the left/right lungs for the COVID-19 CT data were 1.2/1.3 Gy, 0.8/0.9 Gy, 0.8/0.8 Gy and 0.6/0.6 Gy for the PA, AP/PA, 3-field, and 4-field configurations, respectively. Skin dose toxicity was the highest probability for the PA and lowest for the 4-field configuration. Dose to the heart slightly exceeded the ICRP tolerance; all other organ doses were below published tolerances. The AP/PA configuration provided the best fit for entrance skin dose as a function of patient thickness (R 2 = 0.8). The average dose difference between simulation and measurement in the postmortem subject was 5%. Significance. An IR fluoroscope should be capable of delivering low-dose radiotherapy to the lungs with tolerable collateral dose to nearby organs.