Daniel Moreno

Daniel Moreno

Auto-generated profile, based on publicly available information

Daniel Moreno

Herbert Wertheim School of Public Health and Human Longevity, University of California, San Diego, San Diego, CA, United States

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2020 in International Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
DMDaniel Moreno
Daniel Moreno
EGEvan Glasheen
Evan Glasheen
ADAntoinette Domingo
Antoinette Domingo
VPVan Brian Panaligan
Van Brian Panaligan
TPTaylor Penaflor
Taylor Penaflor
JKJochen Kressler
Jochen Kressler
The objective of this study was to investigate the validity of measured caloric expenditure from a fitness smartwatch designed to measured values in wheelchair users against criterion values from a portable metabolic system. 15 wheelchair users and 15 able-bodied participants completed multiple tasks; wheelchair treadmill routine at 30, 45, and 60 strokes per minute, arm cycle ergometry at 45, 60, and 80 revolutions per minute, and arm cycle ergometry VO2Peak test. There were no interactions for device or task and group (wheelchair users vs. able bodied, p=0.375-0.944) therefore results were pooled across groups for all measures. The smartwatch exhibited poor to moderate caloric expenditure association during wheelchair treadmill routine (ICC<0.39) and arm cycle ergometry (ICC<0.541). Smartwatch underestimated caloric expenditure during the wheelchair treadmill task (Mean differences (Limits of Agreement)) (−2.11 (−8.19–3.96), −3.68 (−12.64–5.28), and −4.51 (−15.05–6.02)) and overestimated during the arm cycle ergometry task (0.89 (−3.10–4.88), 3.40 (−0.31–7.12), and 2.81 (−1.71–7.32)). The smartwatch is currently not well suited to calculate caloric expenditure when performing exercise tasks on a wheelchair treadmill and arm cycle ergometry.

26 February 2025 in JMIR Aging
Verified
Journal Article
Open access
DWDavid Wing
David Wing
JNJeanne F Nichols
Jeanne F Nichols
HBHava Shoshana Barkai
Hava Shoshana Barkai
OCOlivia Culbert
Olivia Culbert
DMDaniel Moreno
Daniel Moreno
RMRyan Moran
Ryan Moran
Background: Injuries from falls are a major concern among older adults. Targeted exercise has been shown to improve fall risk, and recommendations for identifying and referring older adults for exercise-based interventions exist. However, even when very inexpensive or free, many do not use available fall prevention programs, citing barriers related to convenience and safety. These issues are even greater among older adults residing in rural areas where facilities are less abundant. These realities highlight the need for different approaches to reducing falls in novel ways that increase reach and are safe and effective. Web-based delivery of exercise interventions offers some exciting and enticing prospects. Objective: Our objective was to assess the efficacy of the Strong Foundations exercise program to change markers of physical function, posture, balance, strength, and fall risk. Methods: Strong Foundations is a once weekly (60 minutes), 12-week iterative program with 3 core components: postural alignment and control, balance and mobility, and muscular strength and power. We used a quasi-experimental design to determine changes in physical function specific to balance, postural control, and muscular strength among older adults at low or moderate risk of falling. Results: A total of 55 low-risk and 37 moderate-risk participants were recruited. Participants significantly improved on the 30-second Chair Stand (mean change of 1, SD 3.3 repetitions; P=.006) and Timed Up and Go (mean change of 0.2, SD 0.7 seconds; P=.004), with the moderate-risk group generally improving to a greater degree than the low-risk group. Additionally, Short Physical Performance Battery performance improved significantly in the moderate-risk category (P=.02). The majority of postural measures showed statistically significant improvement for both groups (P<.05). Measures of “relaxed” posture showed improvements between 6% and 27%. When an “as tall as possible” posture was adopted, improvements were ~36%. Conclusions: In this 12-week, iterative, web-based program, we found older adults experienced improvement not only in measures used in clinical contexts, such as the 30-second Chair Stand and Timed Up and Go, but also contextualized gains by providing deeper phenotypical measurement related to posture, strength, and balance. Further, many of the physical improvements were attenuated by baseline fall risk level, with those with the highest level of risk having the greater gains, and, thus, the most benefit from such interventions.

21 November 2024 in JMIR Preprints
Verified
Preprint
Open access
DWDavid Wing
David Wing
JNJeanne F Nichols
Jeanne F Nichols
HBHava Shoshana Barkai
Hava Shoshana Barkai
OCOlivia Culbert
Olivia Culbert
DMDaniel Moreno
Daniel Moreno
RMRyan Moran
Ryan Moran
BACKGROUND Injuries from falls are a major concern among older adults. Targeted exercise has been shown to improve fall risk, and recommendations for identifying and referring older adults for exercise-based interventions exist. However, even when very inexpensive or free, many do not use available fall prevention programs, citing barriers related to convenience and safety. These issues are even greater among older adults residing in rural areas where facilities are less abundant. These realities highlight the need for different approaches to reducing falls in novel ways that increase reach and are safe and effective. Web-based delivery of exercise interventions offers some exciting and enticing prospects. OBJECTIVE Our objective was to assess the efficacy of the Strong Foundations exercise program to change markers of physical function, posture, balance, strength, and fall risk. METHODS Strong Foundations is a once weekly (60 minutes), 12-week iterative program with 3 core components: postural alignment and control, balance and mobility, and muscular strength and power. We used a quasi-experimental design to determine changes in physical function specific to balance, postural control, and muscular strength among older adults at low or moderate risk of falling. RESULTS A total of 55 low-risk and 37 moderate-risk participants were recruited. Participants significantly improved on the 30-second Chair Stand (mean change of 1, SD 3.3 repetitions; P=.006) and Timed Up and Go (mean change of 0.2, SD 0.7 seconds; P=.004), with the moderate-risk group generally improving to a greater degree than the low-risk group. Additionally, Short Physical Performance Battery performance improved significantly in the moderate-risk category (P=.02). The majority of postural measures showed statistically significant improvement for both groups (P<.05). Measures of “relaxed” posture showed improvements between 6% and 27%. When an “as tall as possible” posture was adopted, improvements were ~36%. CONCLUSIONS In this 12-week, iterative, web-based program, we found older adults experienced improvement not only in measures used in clinical contexts, such as the 30-second Chair Stand and Timed Up and Go, but also contextualized gains by providing deeper phenotypical measurement related to posture, strength, and balance. Further, many of the physical improvements were attenuated by baseline fall risk level, with those with the highest level of risk having the greater gains, and, thus, the most benefit from such interventions.

4 September 2026 in JMIR Formative Research
Verified
Journal Article
Open access
NNNicholas Noggle
Nicholas Noggle
DWDavid Wing
David Wing
JGJob G Godino
Job G Godino
MHMichael Higgins
Michael Higgins
DMDaniel Moreno
Daniel Moreno
RMRyan Moran
Ryan Moran
Background: Commercially available wearable devices, capable of measuring cardiac rhythm, are gaining popularity for convenient heart health monitoring. Accurate measurement of key intervals, specifically RR intervals for rhythm and QT and corrected QT (QTc) intervals for arrhythmia risk, is crucial for assessing potential cardiac morbidity. Objective: This study aimed to evaluate the agreement of RR, QT, and QTc intervals measured by a consumer wearable device (Withings ScanWatch series 1) with those measured using a research-grade 3-lead electrocardiogram (ECG; Biopac) and a clinically approved single-lead patch (Cardea SOLO). Methods: This was a cross-sectional study of 28 healthy adults aged 21 to 65 years, with a mean age of 39.4 (SD 13.0) years. Participants underwent 4 concurrent ECG measurements per device: twice seated at rest, once supine, and once after exercise. All RR and QT intervals were manually measured using standardized caliper software (EP calipers) by trained reviewers, and QTc was calculated using the Bazett formula. Agreement was assessed via repeated-measures correlation ( r rm ) and linear mixed-effects models (LMMs) for repeated-measures Bland-Altman analysis. Results: Strong agreement was observed for RR intervals when comparing the Withings ScanWatch with both the Biopac ( r rm =0.84; P< .001) and the SOLO ( r rm =0.80; P <.001). Agreement was weaker for QT intervals ( r rm =0.37; P =.001 compared to Biopac and r rm =0.37; P =.001 compared to SOLO) and QTc intervals ( r rm =0.27; P =.01 compared to Biopac and r rm =0.27; P =.03 compared to SOLO). Bland-Altman LMM analysis demonstrated that the Withings ScanWatch systematically underestimated QT intervals, with a mean error (ME) of −42.9 (SD 30.1) milliseconds versus Biopac and −15.8 (SD 20.6) milliseconds versus SOLO. Similarly, QTc intervals were underestimated, with an ME of −51.4 (SD 32.3) milliseconds versus Biopac and −18.8 (SD 21.5) milliseconds versus SOLO. Conclusions: While the Withings ScanWatch showed strong agreement for RR interval measurement, its variability and systematic underestimation in QT and QTc measurements limited its clinical applicability for accurate assessment of arrhythmia risk. The device may serve as a valuable tool for tracking trends over time, but it is currently unreliable for precise interval screening.