Jinlei Liu

Jinlei Liu

Auto-generated profile, based on publicly available information

Jinlei Liu

School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2023 in Plant Physiology
Verified
Journal Article
Closed access
PDF file
FYFeifei Yi
Feifei Yi
ASAosong Song
Aosong Song
KCKai Cheng
Kai Cheng
JLJinlei Liu
Jinlei Liu
CWChenxiao Wang
Chenxiao Wang
YCYingfan Cai
Yingfan Cai
Verticillium wilt caused by Verticillium dahliae is a serious vascular disease in cotton (Gossypium spp.). V. dahliae induces the expression of the CAROTENOID CLEAVAGE DIOXYGENASE 7 (GauCCD7) gene involved in strigolactone (SL) biosynthesis in Gossypium australe, suggesting a role for SLs in Verticillium wilt resistance. We found that the SL analog rac-GR24 enhanced while the SL biosynthesis inhibitor TIS108 decreased cotton resistance to Verticillium wilt. Knock-down of GbCCD7 and GbCCD8b genes in island cotton (Gossypium barbadense) decreased resistance, whereas overexpression of GbCCD8b in upland cotton (Gossypium hirsutum) increased resistance to Verticillium wilt. Additionally, Arabidopsis (Arabidopsis thaliana) SL mutants defective in CCD7 and CCD8 putative orthologs were susceptible, whereas both Arabidopsis GbCCD7- and GbCCD8b-overexpressing plants were more resistant to Verticillium wilt than wild-type (WT) plants. Transcriptome analyses showed that several genes related to the jasmonic acid (JA)- and abscisic acid (ABA)-signaling pathways, such as MYELOCYTOMATOSIS 2 (GbMYC2) and ABA-INSENSITIVE 5, respectively, were upregulated in the roots of WT cotton plants in responses to rac-GR24 and V. dahliae infection but downregulated in the roots of both GbCCD7- and GbCCD8b-silenced cotton plants. Furthermore, GbMYC2 suppressed the expression of GbCCD7 and GbCCD8b by binding to their promoters, which might regulate the homeostasis of SLs in cotton through a negative feedback loop. We also found that GbCCD7- and GbCCD8b-silenced cotton plants were impaired in V. dahliae-induced reactive oxygen species (ROS) accumulation. Taken together, our results suggest that SLs positively regulate cotton resistance to Verticillium wilt through crosstalk with the JA- and ABA-signaling pathways and by inducing ROS accumulation.

1 January 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JJJin Jin
Jin Jin
JLJinlei Liu
Jinlei Liu
YLYunqing Liu
Yunqing Liu
Chengjin QinChengjin Qin
Chengjin Qin
ZLZhiyuan Li
Zhiyuan Li
CLChengliang Liu
Chengliang Liu
Arrhythmia accounts for more than 80% of sudden cardiac death, and its incidence rate has increased rapidly recently. Nowadays, many studies have applied artificial intelligence (AI) methods to arrhythmia detection. Deep learning approaches can improve model performance but lack the capability to mine the relationship between the electrocardiogram (ECG) samples and final results. Furthermore, most arrhythmia diagnosis methods aim at only multiclassification problems. However, in many cases, an ECG recording may have more than one arrhythmia disease. In this article, we develop an accurate and interpretable model for multilabel ECG signals, which is called dual-level attentional convolutional long short-term memory neural network (DLA-CLSTM). Convolutional layers, bidirectional long short-term memory layers, and attention mechanisms are used for extracting beat- and rhythm-level information. Notably, the attention mechanism helps the model be more interpretable. In addition, we design a weighted multilabel classifier to address multilabel and imbalance problems. Finally, the MIT-BIH Arrhythmia Database and the 1st China Physiological Signal Challenge dataset are utilized to evaluate DLA-CLSTM. Compared with existing methods, DLA-CLSTM can improve the accuracy by 22.50% and the F1-macro by 20.51% on average. Further analysis shows that the areas focused by DLA-CLSTM match the clinical judgment basis to some extent. Collectively, DLA-CLSTM has good potential for assisting clinicians in real applications.

3 July 2022 in Expert Review of Medical Devices
Verified
Journal Article
Closed access
JLJinlei Liu
Jinlei Liu
ZLZhiyuan Li
Zhiyuan Li
YJYanrui Jin
Yanrui Jin
YLYunqing Liu
Yunqing Liu
CLChengliang Liu
Chengliang Liu
XCXiaojun Chen
Xiaojun Chen
With the widespread availability of portable electrocardiogram (ECG) devices, there will be a surge in ECG diagnoses. Traditional computer-aided diagnosis of arrhythmia mainly relies on the rules o...

1 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JJJin Jin
Jin Jin
Chengjin QinChengjin Qin
Chengjin Qin
JLJinlei Liu
Jinlei Liu
ZLZhiyuan Li
Zhiyuan Li
HSHaotian Shi
Haotian Shi
CLChengliang Liu
Chengliang Liu
In the actual scenario, it is difficult for an automatic diagnosis system to detect each heartbeat when facing new patients. In this article, a novel active dual-scale residual convolutional long short-term memory neural network is proposed to classify heartbeats interactively and automatically. First, each heartbeat and electrocardiogram segment including current heartbeat are combined to build dual-scale input information. In addition, convolution layers, residual block, and bidirectional long short memory are integrated to extract features from dual-scale inputs. Furthermore, active learning approach with random breaking-ties selection strategy is introduced to choose the most representative unlabeled samples for labeling and fine-tune the trained model with these representative labeled samples. The experimental results show that the proposed method uses only 5.14% of the additional data set and improves the model accuracy and macro F1 score by 13.23% and 35.62%, respectively. The proposed structure has good representative ability and our selection strategy can reduce the workload of experts and improve the performance greatly. Thus, the proposed interactive and incremental method has good potential in real applications.

17 May 2022 in Knowledge-Based Systems
Verified
Journal Article
Closed access
YLYunqing Liu
Yunqing Liu
Chengjin QinChengjin Qin
Chengjin Qin
JLJinlei Liu
Jinlei Liu
YJYanrui Jin
Yanrui Jin
ZLZhiyuan Li
Zhiyuan Li
CLChengliang Liu
Chengliang Liu

18 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZLZhiyuan Li
Zhiyuan Li
YTYuanyuan Tian
Yuanyuan Tian
JJJin Jin
Jin Jin
XWXiaoyang Wei
Xiaoyang Wei
MWMengxiao Wang
Mengxiao Wang
CLChengliang Liu
Chengliang Liu
Background: Electrocardiogram (ECG), as a low-cost and non-invasive measurement tool, plays a crucial role in detecting arrhythmias. However, the ECG measurement process is highly vulnerable to factors such as baseline wandering, electrode motion, and muscle artifacts, leading to significant degradation in signal quality. Consequently, exploring denoising methods to obtain clean ECGs has emerged as an essential and challenging task. Methods: We propose a novel denoising method for ECG signals called the ECG Denoising Diffusion Model (EDDM). Unlike traditional generative methods, EDDM employs two distinct pathways in the forward stage: ECG noise diffusion and Gaussian white noise diffusion. This unique approach allows for directed diffusion from the clean ECG domain to the measured ECG domain. In the reverse process, we design a U-Net model that combines deep aggregation pyramid pooling layers to accurately capture the multi-scale information of the ECG for predicting the two types of noise during the diffusion process. Therefore, EDDM follows an interpretable denoising path and directly obtains the clean ECG from the noisy ECG instead of using a generative approach, resulting in more intuitive and stable denoising outcomes. Conclusion: EDDM has achieved state-of-the-art (SOTA) results on five metrics in benchmark experiments, with a significant improvement of 4%-10% in the percentage root-meansquare difference (PRD) compared to the existing SOTA model. Analysis shows that EDDM interpretably achieves the diffusion of clean ECG into noisy ECG, rather than white noise. Furthermore, under extreme noise conditions, EDDM achieves more stable and higher-performance denoising results compared to the SOTA method, demonstrating the enormous potential of EDDM in wearable ECG measurement systems.