18 February 2020 in Physical Review Letters
The introduction of optical tweezers for trapping atoms has opened remarkable opportunities for manipulating few-body systems. Here, we present the first bottom-up assembly of atom triads. We directly observe atom loss through inelastic collisions at the single event level, overcoming the substantial challenge in many-atom experiments of distinguishing one-, two-, and three-particle processes. We measure a strong suppression of three-body loss, which is not fully explained by the presently availably theory for three-body processes. The suppression of losses could indicate the presence of local anticorrelations due to the interplay of attractive short range interactions and low dimensional confinement. Our methodology opens a promising pathway in experimental few-body dynamics.
19 April 2023 in NMR in Biomedicine
Inversion pulses are commonly employed in MRI for ‐weighted contrast and relaxation measurements. In the brain, it is often assumed that adiabatic pulses saturate the nonaqueous magnetization. We investigated this assumption using solid‐state NMR to monitor the nonaqueous signal directly following adiabatic inversion and compared this with signals following hard and soft inversion pulses. The effects of the different preparations on relaxation dynamics were explored. Inversion recovery experiments were performed on ex vivo bovine and porcine brains using 360‐MHz (8.4 T) and 200‐MHz (4.7 T) NMR spectrometers, respectively, using broadband rectangular, adiabatic, and sinc inversion pulses as well as a long rectangular saturation pulse. Analogous human brain MRI experiments were performed at 3 T using single‐slice echo‐planar imaging. Relaxation data were fitted by mono‐ and biexponential decay models. Further fitting analysis was performed using only two inversion delay times. Adiabatic and sinc inversion left much of the nonaqueous magnetization along and resulted in biexponential relaxation. Saturation of both aqueous and nonaqueous magnetization components led to effectively monoexponential relaxation. Typical adiabatic inversion pulses do not, as has been widely assumed, saturate the nonaqueous proton magnetization in white matter. Unequal magnetization states in aqueous and nonaqueous 1H reservoirs prepared by soft and adiabatic pulses result in biexponential relaxation. Both pools must be prepared in the same magnetization state (e.g., saturated or inverted) in order to observe consistent monoexponential relaxation.