Ryota Inai

Ryota Inai

Auto-generated profile, based on publicly available information

Ryota Inai

From the Department of Radiology (T.T., M.Y., A.K.) and Department of Hematology and Medical Oncology (A.H.B.), Mayo Clinic, Scottsdale, Ariz; Department of Radiology, Okayama University Hospital, 2-5-1 Shikata-cho, Okayama 700-8558, Japan (T.T., R.I., S.K.); and Department of Radiology, Mayo Clinic, Rochester, Minn (A.T.F.).

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in RadioGraphics
Verified
Journal Article
Closed access
TTTakashi Tanaka
Takashi Tanaka
MYMing Yang
Ming Yang
AFAdam T. Froemming
Adam T. Froemming
ABAlan Bryce
Alan Bryce
RIRyota Inai
Ryota Inai
AKAkira Kawashima
Akira Kawashima
In patients with locally recurrent and metastatic prostate cancer, it is clinically important that radiologists be familiar with the strengths and limitations of imaging modalities for diagnosis an... Relapsing level of prostate-specific antigen (PSA) after initial curative-intent local therapy for organ-confined prostate cancer is often the first sign of recurrence. However, PSA level recurrenc...

28 January 2020 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
RIRyota Inai
Ryota Inai
RNRyuichi Nakahara
Ryuichi Nakahara
YMYusuke Morimitsu
Yusuke Morimitsu
NANoriaki Akagi
Noriaki Akagi
YMYouhei Marukawa
Youhei Marukawa
SKSusumu Kanazawa
Susumu Kanazawa
Background: To reveal trends in bone microarchitectural parameters with increasing spatial resolution on ultra-high-resolution computed tomography (UHRCT) in vivo and to compare its performance with that of conventional-resolution CT (CRCT) and micro-CT ex vivo. Methods: We retrospectively assessed 5 tiger vertebrae ex vivo and 16 human tibiae in vivo. Seven-pattern and four-pattern resolution imaging were performed on tiger vertebra using CRCT, UHRCT, and micro-CT, and on human tibiae using UHRCT. We measured six microarchitectural parameters: volumetric bone mineral density (vBMD), trabecular bone volume fraction (bone volume/total volume, BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), trabecular separation (Tb.Sp), and connectivity density (ConnD). Comparisons between different imaging resolutions were performed using Tukey or Dunnett T3 test. Results: The vBMD, BV/TV, Tb.N, and ConnD parameters showed an increasing trend, while Tb.Sp showed a decreasing trend both ex vivo and in vivo. Ex vivo, UHRCT at the two highest resolutions (1024- and 2048-matrix imaging with 0.25-mm slice thickness) and CRCT showed significant differences (p ≤ 0.047) in vBMD (51.4 mg/cm3 and 63.5 mg/cm3versus 20.8 mg/cm3), BV/TV (26.5% and 29.5% versus 13.8 %), Tb.N (1.3 l/mm and 1.48 l/mm versus 0.47 l/mm), and ConnD (0.52 l/mm3 and 0.74 l/mm3versus 0.02 l/mm3, respectively). In vivo, the 512- and 1024-matrix imaging with 0.25-mm slice thickness showed significant differences in Tb.N (0.38 l/mm versus 0.67 l/mm, respectively) and ConnD (0.06 l/mm3versus 0.22 l/mm3, respectively). Conclusions: We observed characteristic trends in microarchitectural parameters and demonstrated the potential utility of applying UHRCT for microarchitectural analysis.