25 July 2018 in IEEE Transactions on Power Systems
Volt/var control (VVC) is one of the primary functions of the distribution management system aiming at optimum operation of power distribution networks while respecting all of their operational and security constraints. However, the recent huge integration of highly stochastic distributed generation (DG) sources with the grid presents a significant challenge to the traditionalVVCschemes,whichassumethefuturetobeperfectly known. This paper presents a two-stage chance constrained optimization scheme to handle these nodal power uncertainties and guarantees that the operational and security constraints are respectedforalmostallrealizationsoftheuncertainty.Thechance constrained model is solved by collecting enough randomly chosen samples from the probability spaces of the uncertain parameters so that the class of the problem, a mixed integer second order cone program (MISOCP), is not elevated. The algorithm not only dispatches the optimum schedule for discrete controlling devices like transformers and shunt capacitors but also optimizes the predefined decision rules for reactive power control of DG sources, thus falling in line with the requirement laid down in the revised IEEE 1547 Standard. Numerical simulations on three different test systems show the superiority of the proposed algorithm over the traditional deterministic methods.
27 April 2020 in IEEE Transactions on Energy Conversion
This paper presents a two-stage three-phase solar photovoltaic (PV) system, which is controlled through a novel enhanced second order generalized integrator (ESOGI) based control technique. The proposed ESOGI is used for fundamental component extraction from nonlinear load current and distorted grid voltages. This integrator effectively and simultaneously manages to address the DC offset, inter-harmonic and integrator delay problems of the traditional SOGI. In addition, this control technique provides power factor correction, harmonic elimination, and load balancing functionalities. The ESOGI controller is used to generate reference grid currents for controlling the voltage source converter (VSC), interfacing the PV panel with the grid. Extensive experimental results on a developed prototype in the laboratory, depict that the total harmonic distortion (THD) of the grid injected currents and voltages are found well under IEEE-519 standard.
18 March 2022 in IEEE Transactions on Power Systems
This paper proposes a completely non-centralized Volt/VAr control (VVC) algorithm for active distribution networks which are faced with voltage magnitude violations due to the high penetration of solar photovoltaics (PVs). The proposed VVC algorithm employs a two-stage architecture where the settings of the classical voltage control devices (VCDs) are decided in the first stage through a distributed optimization engine powered by the alternating direction method of multipliers (ADMM). In contrast, the PV smart inverters are instructed in the second stage through linear Q(P) decision rules - which are computed in a decentralized manner by leveraging robust optimization theory. The key to this non-centralized VVC routine is a proposed network partition methodology (NPM) which uses an electrical distance metric based on node $Q-|V|^{2}$ sensitivities for computing an intermediate reduced graph of the network, which is subsequently divided into the final partitions using the spectral clustering technique. As a result, the final network partitions are connected, stable, close in cardinality, contain at least one PV inverter for zonal reactive power support, and are sufficiently decoupled from each other. Numerical results on the UKGDS-95 and IEEE-123 bus systems show that the non-centralized solutions match closely with the centralized robust VVC schemes, thereby significantly reducing the voltage violations compared to the traditional deterministic VVC routines.
12 June 2020 in IEEE Transactions on Smart Grid
This paper presents a fully distributed algorithm for the stochastic Volt/VAr control (VVC) problem in active distribution networks. Exact convexification of the VVC problem is achieved through the use of second-order cones on the continuous relaxation of the original optimization structure. The global optimum solution of the relaxed problem is obtained through the application of the alternating direction method of multipliers (ADMM). In order to minimize the effect of rounding off on the final solution, an adaptive threshold discretization technique is used. A two-stage control strategy is adopted where the discrete controllers, like load tap changers and switched capacitors, are dispatched at the beginning of the optimization interval and the continuous controllers, like distributed generation (DG) inverters, are adjusted in real time according to an optimized decision rule. The superiority of the proposed algorithm is demonstrated through numerical simulations on the UKGDS-95 and the IEEE-123 bus systems.
7 October 2020 in IEEE Transactions on Power Systems
The global optimum of the optimal power flow (OPF) problem can be sought in various practical settings by adopting the conic relaxations, such as the second order cone programs (SOCPs) and semi-definite programs (SDPs). However, the ZIP (constant impedance, constant current, constant power) and exponential load models are not directly amenable with these conic solvers. Thus, these are mostly treated as constant power loads in the literature. In this letter, we propose two simple methods to approximate these static loads with good accuracy. The proposed methods perform much better than the traditional constant power approximation.
12 March 2025 in IEEE Transactions on Instrumentation and Measurement
The state estimation of an active distribution network (ADN) in the absence of enough measurements, and with the presence of distributed energy resources (DERs) located behind-the-meter (BTM), is a significant challenge. The operational philosophy of power distribution networks is also changing from "generation following demand" to "demand following generation". Consequently, emerging demand and generation patterns are difficult to handle through standard state estimators. This paper introduces a profiling framework that characterises responsive/flexible demands and BTM DERs to represent non-conventional load power. The impact of these non-conventional load power on distribution network monitoring and the challenges of system observability are addressed using a deep learning-based forecaster. This forecaster utilises weather and other relevant input features to tackle the irregularities in demand profiles. Additionally, the framework includes proposing a strategy for time-varying smoothing parameters in forecasting-aided state estimation to address the uncertainties associated with loads and the outputs of DERs. The framework is validated on a modified IEEE-123 bus unbalanced three-phase distribution network for demonstrating improved accuracy of the estimation.