28 October 2020 in Spine Deformity
17 December 2015 in Foot & Ankle International
Prevention of surgical site infections and the reduction of wound-related complication rates have become increasingly emphasized by hospital task groups and government agencies given the degree of economic burden it places on the health care system. Platelet-rich plasma (PRP) contains growth factors and other biomolecules that promote endogenous microbicidal activity. We hypothesized that PRP would help prevent postoperative infection and delayed wound healing (DWH). We randomized patients having foot or ankle surgery to the treatment group receiving intraoperative PRP (applied to operative field) and platelet-poor plasma at closing (PPP, on the sutured skin) or the control group (no PRP/PPP). The incidence of deep surgical site infection and DWH (collectively called endpoints) was compared between groups (n = 250/group). PRP had a mean 5.3-fold platelet concentration compared to whole blood, with concentrated white blood cells. Mean age (±SD) of patients was 52 years (±15), 65% were women. Minor and major operative procedures were included. Patients were followed for 60 days. Seventy controls had PRP prepared for assay of growth factors. Procedure mix, ASA scores, mean operative times, and comorbidity mix were similar between groups. The primary result was no difference in number of endpoints between groups: 19 patients in the PRP group (7.6%) versus 18 controls (7.2%). Endpoints were deep surgical site infections in 2 PRP/PPP patients and 1 control, and DWH in 17 PRP/PPP patients and 17 controls. Analysis of PRP samples revealed a large variation in growth factor concentrations between patients. Intraoperative application of PRP/PPP did not reduce the incidence of postoperative infection or DWH. Growth factor profiles varied greatly between patients, suggesting that the potentially therapeutic treatment delivered was not consistent from patient-to-patient. Level I, prospective randomized trial.
6 February 2020 in Journal of Pediatric Orthopaedics
Purpose: Repeat intervention for pediatric forearm fractures after closed manipulation is as high as 46% with flexed elbow (FE) long-arm casts. Casting with the elbow extended (EE) has been advocated as an alternative technique. We documented outcomes of patients treated with closed manipulation and casting with EE long-arm casts for displaced, diaphyseal both-bone forearm fractures. Methods: We retrospectively reviewed charts for patients who had sedated manipulations and casting for closed, diaphyseal forearm fractures. Open fractures, immediate surgical intervention, metabolic bone disease, recurrent fractures, and Monteggia injuries were excluded. Closed manipulations were performed by orthopaedic residents assisted by cast technicians, with sedation provided by emergency department physicians. Radiographic angulation and displacement of the radius and ulna on immediate postreduction radiographs and all follow-up radiographs were recorded. Patients requiring repeat intervention were compared with those who did not by using the Mann-Whitney U and Fisher exact tests. Results: Of 86 patients (7.2±2.8 y) available for analysis, 82 (95.3%) completed treatment after a single-sedated manipulation and placement of an EE long-arm cast. There were no malunions or nonunions. The average follow-up was 50 days. Four (4.7%) patients required repeat interventions (2 had surgery, 1 had a repeat sedated manipulation, and 1 had a nonsedated manipulation). There were no statistically significant differences in age, sex, laterality, fracture position in the diaphysis, or immediate postreduction angulation of the radius or ulna. A literature review showed average repeat intervention rates of 14.9% (range, 0% to 45.9%) for FE casts and 3.3% (range, 0% to 15%) for EE casts. Conclusions: There was a low rate of repeat interventions (4.7%) in patients with EE casts compared with historical rates for FE casts. Improving the quality of health care involves identifying and implementing practices that provide the best outcomes at the lowest costs. The use of EE long-arm casts following closed manipulation of pediatric forearm fractures may decrease the rate of repeat manipulation or surgery compared with conventional FE casts. Level of Evidence: Level IV—case series.
1 September 2019 in Journal of Clinical Research in Pediatric Endocrinology
Reports suggesting that vitamin D may have extraskeletal roles have renewed interest in vitamin D research and stimulated publication of an increasing number of new studies each year. These studies typically assess vitamin D status by measuring the blood concentration of 25-hydroxyvitamin D [25(OH)D], the principal circulating metabolite of vitamin D. Unfortunately, variations in assay format, inconsistency in interpreting 25(OH)D concentrations, cohort bias (age, body mass index, race, season of measurements etc.) and failure to measure critical variables needed to interpret study results, makes interpreting results and comparing studies difficult. Further, variation in reporting results (reporting mean values vs. percent of the cohort that is deficient, no clear statement as to clinical relevance of effect size, etc.) further limits interstudy analyses. In this paper, we discuss many common pitfalls in vitamin D research. We also provide recommendations on avoiding these pitfalls and suggest guidelines to enhance consistency in reporting results.
12 August 2024 in Spine Deformity