Sumi Yoon

Sumi Yoon

Auto-generated profile, based on publicly available information

Sumi Yoon

Korea Electronics Technology Institute

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2020 in BioChip Journal
Verified
Journal Article
Closed access
PDF file
HKHye-Lim Kang
Hye-Lim Kang
SYSumi Yoon
Sumi Yoon
DHDong-Ki Hong
Dong-Ki Hong
SSSunga Song
Sunga Song
YKYoung Joo Kim
Young Joo Kim
KLKook-Nyung Lee
Kook-Nyung Lee

1 June 2016 in Microelectronic Engineering
Verified
Journal Article
Closed access
KLKook-Nyung Lee
Kook-Nyung Lee
YSYeong-Tai Seo
Yeong-Tai Seo
YKYong-Kweon Kim
Yong-Kweon Kim
SYSumi Yoon
Sumi Yoon
MLMin-Ho Lee
Min-Ho Lee
WSWooKyeong Seong
WooKyeong Seong

1 May 2020 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
SSSunga Song
Sunga Song
YKYoung Joo Kim
Young Joo Kim
HKHye-Lim Kang
Hye-Lim Kang
SYSumi Yoon
Sumi Yoon
DHDong-Ki Hong
Dong-Ki Hong
KLKook-Nyung Lee
Kook-Nyung Lee
The electrochemical biosensors are widely used in point-of-care test (POCT) applications because of their simple measurement methods and their ease of implementation in small diagnostic devices. Most electrochemical biosensors perform sample analysis one by one, and there are limitations to using electrochemical immunoassays as multiple reactions and multiple assays required in practical POCT applications. Here, we developed a multi-channel electrochemical immunoassay system and simultaneously assayed one set of electrochemical ELISA. We quantitatively analyzed with electrocmafhemical measurements using multiple sensor arrays. In the immune reaction, we used 8 microwell array in 96-well plate (8 by 12) using magnetic nanoparticles (MNPs). As a model system, the immune reaction of the sandwich method of detecting matrix metalloproteinase-9 (MMP-9) as a bladder cancer marker using MNPs coated with streptavidin was performed. Matrix metalloproteinases play a major role in the invasion and metastasis of cancer cells, and MMP-9 is produced in both normal and cancer cells. MMP-9 is known to be closely associated with malignancy of tumor cells. In the experiment, the 96-well plate and multi-channel immunoassay system-assay were used. To immobilize biotinylated MMP-9 on streptavidin-coated MNPs, 15 μL of a 1% PBST buffer solution containing 10 µg/ml biotinylated MMP-9 was incubated onto the streptavidin-coated MNPs, the incubated state was maintained for 30 min at 25 °C, and the MNPs were washed three times with rinsing buffer. Subsequently, 15 μL of a 1% BSA buffer solution was incubated onto the biotinylated MMP-9 modified MNPs, then incubated state was maintained for overnight at 4 °C, and the electrodes were washed three times with rinsing buffer. The resulting MNPs were stored at 4 °C before their use. The storage solution should use 1% BSA. For the binding of the target protein to the MNPs, 150 μL of 1 % PBST buffer solutions containing different concentrations of MMP-9 were incubated onto the MNPs, the incubated state was maintained for 30 min at 25 °C, and MNPs were washed three times with rinsing buffer. Afterward, 150 μL of a 1%BSA buffer solution containing 1 µg/ml enzyme alkaline phosphatase-conjugated MMP-9 were incubated on the target-treated MNPs, and the incubated state was maintained for 30 min at 25 °C, followed by washing three times with rinsing buffer. All reactions at 25 °C were made with a shaker. After completion of the immune reaction, the MNPs were performed by electrochemical measuring using a multi-array instrument after the reaction in a substrate solution. 100 μL of a tris-buffer solution containing 1mM ascorbic acid 2-phosphate (AAP) were incubated on the prepared MNPs, and the incubated state was maintained for 10 min at 25 °C, and the MNPs were then removed. In the solution, the reaction between AAP and ALP no longer occurs, and only AAP which does not react with ascorbic acid (AA), which is completed, is present. Here AA and AAP have electrochemically different physical properties and can only detect oxidation of AA in a specific voltage range. The results of the immune reaction were measured using a multichannel immunoassay system-detection developed to measure electrochemical signals. The electrochemical sensor modules are only exposed to the complete solution of the substrate reaction and can be reused after a wash, which will be useful in practical applications. A multichannel electrochemical sensor array was added to the reaction solution and subjected to chronocoulometry (CC). As a result, the measuring range is 10 pM to 10 nM, and the detection limit is 0.35 pM. In other words, the detection limit of 0.322 ng / mL and the measurement range of 0.92 - 920 ng/ ml have similar sensitivity and higher assay range as commercialized MMP-9 ELISA kit All reactions related to immune reaction were made possible by multiple reactions in 1 set unit using MNPs. Besides, by separating the signal measurement surface and the immune reaction surface, the enzyme reaction can be terminated at the same time. It is important to terminate the enzymatic reaction at the same time because it is difficult to control the reaction time in an one-by-one electrochemical immunoassay. Thereby, the developed system can provide the convenience and simplicity of the electrochemical immunoassay. Previous studies on bladder cancer in our group confirmed that the diagnostic accuracy of two or three multiple makers including MMP-9 was significantly higher than the single marker of MMP-9. The results suggest the necessity of diagnosis using various biomarkers and the importance and the advantage of a multi-channel immunoassay system as well. A multi-channel immune sensor system was developed to measure a wide range of concentrations, from low to high concentration of target markers, and to perform from 1 set of immune reactions to measurements. This work was financially supported by the research funds of the Bio & Medical Technology Development Program of the National Research Foundation (NRF-2015M3A9E2028480) and the research funds (Grant No. 10077648) of the Ministry of trade, Industry and Energy, Korea. Streptavidin coated magnetic nanoparticles were provided by Amolifescience, Co. Ltd, Korea. Figure 1

1 May 2020 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
HKHye-Lim Kang
Hye-Lim Kang
KLKook-Nyung Lee
Kook-Nyung Lee
SYSumi Yoon
Sumi Yoon
DHDong-Ki Hong
Dong-Ki Hong
SSSunga Song
Sunga Song
WSWooKyeong Seong
WooKyeong Seong
Biosensors based on nano field-effect transistor(nanoFET) have been studied to detect from pH to biomolecules and anion in the air because its potential for label-free detection, rapid response time, low-cost and miniaturization [1-3]. The nanoFET sensor detect target species with a conductance change of nanochannel that is induced by the adsorption of charged substance or the surface potential of the sensing gate electrode. However, the sensing area on top of the nanochannel area is very small, the probability of binding of target molecules on the sensing surface of the device is very low. Therefore, we employ an electrically extended sensing electrode in order to improve adsorption probability of the charged substances and detection sensitivity. Here, we analyzed the behavior of the nanoFET sensor with an extended gate electrode and a reference electrode using pH solution of difference pH levels. It is a fundamental study to understand the behavior of nanoFET sensor with extended gate as biosensors, and it is necessary before applying it to various solution environment. Figure 1 shows the schematics of the nanoFET sensor with the extended gate electrode for pH level sensing of solution. The top gate electrode and the bottom substrate gate of the nanoFET sensor are electrically interconnected with the extended external electrode in order to increase the sensing area. The Ids-Vg characteristics of the nanoFET sensor with extended gate electrode, which is obtained by the voltage sweeping of the gate (Vg) as shown in Figure 2. The threshold voltage of the device is approximately -2.5 V. The electrode of an indium tin oxide(ITO) glass and a Ag/AgCl wire are used for the extended sensing gate electrode and the reference electrode. The connection for gate electrode and the reference electrode are compared with three cases of ITO-Ag/AgCl, Ag/AgCl-ITO and ITO-ITO respectively to compare pH response with the Ids-Vg sweep characteristics of the nanoFET sensor. In the pH sensing experiment, about 50 μL-solution having 4, 7 and 9.2 pH level are used, and it is dropped to a micro well on the extended sensing gate electrode as shown in Figure 1. Figure 3 shows Ids-Vg measurement results of varying the pH level on solution for the three connection cases of extended sensing gate electrode and reference electrode using the same device. Figure 3(a) shows Ids-Vg curve is shifted to the right side as the pH level rises in case of the reference electrode is the Ag/AgCl wire and the extended sensing gate electrode is the ITO glass. The response to pH level is shifted to left side as shown in Figure 3(b) when the electrode connection is reversed for the reference electrode and the extended sensing gate electrode with the ITO glass and the Ag/AgCl wire, respectively. In particular, it is confirmed that the nanoFET device don’t respond to the pH change of solution when both the reference electrode and the extended sensing gate electrode are the ITO glass. We finally conclude that the nanoFET sensor with the extended sensing gate electrode is affected by the surface potential in electrolyte solution induced by varying pH level. The equivalent circuit model of the nanoFET sensor is the series interconnection of two opposing electrolytic capacitors and the MOS capacitor of nanoFET device to the applied gate voltage as shown in Figure 4. Therefore, the nanoFET sensor with the extended gate electrode may not respond to the pH change or ion concentration in electrolyte solution when the interface of liquid-reference electrode is equal to interface of liquid-sensing electrode. In this study, we demonstrated experimentally the working principles of the nanoFET sensor with the extended gate electrode with the response to pH level of liquid solution. We found that the equivalent circuit model is the series connection of two opposing electrolytic capacitors in liquid solution and the MOS capacitor of the nanoFET device. The results suggest that the proper reference electrode should be utilized to measure the pH levels in liquid solution of nanoFET sensor and the other adequate reference electrode might be used to remove the effects induced by pH noise for the biosensor application such as immunosensors. This work was financially supported by the research funds (Grant No. 10076874 and No. 10077599) of the Ministry of trade, Industry and Energy, Korea [1]Matti Kaisti, Detection principles of biological and chemical FET sensors, Biosensors and Bioelectronics, 98 (2017) [2]Benjamin M. Lowe et al. Field-effect sensors-from pH sensing to biosensing: sensitivity enhancement using streptavidin-biotin as a model system, Analyst 142 (2017) [3]K.-N. Lee et al. Chemical gating experiment of a nano-field-effect transistor sensor using the detection of negative ions in air, Sens. Actuators, B 236 (2016) Figure 1

1 May 2020 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
SYSumi Yoon
Sumi Yoon
KLKook-Nyung Lee
Kook-Nyung Lee
DHDong-Ki Hong
Dong-Ki Hong
HKHye-Lim Kang
Hye-Lim Kang
SSSunga Song
Sunga Song
HKHyewon Kim
Hyewon Kim
Colorimetric sensor arrays were developed to detect gas molecules by changing colors a decade ago.[1] Since the colors of the sensors change while specific gas molecules interact with an array of the colorimetric chemical sensor, the technique for measuring and analyzing the changes of the colors upon gas interactions is very important. Most of the color reading method for the sensor array is to obtain images using color scanners or digital cameras. If the spatiotemporal condition for obtaining images is inconstant, reading and interpreting the color change information upon the interaction of the gas sensors with the gas molecules must be inaccurate. In addition, most systems for analyzing color changes are laborious and time-consuming to find locations for accurate analyses using a desktop computer.[2] Here we have developed a smartphone-based colorimetric sensor array reader system that simply analyzes color changes. This system consists of a housing unit that maintains a constant position of the sensor array and provides illumination with the same brightness, a smartphone camera and an image analysis Android OS-based application. After acquiring the sensor array images before and after injection of the target gas by a smartphone camera, the application program automatically assigns positions of the color sensor array for the color analysis and obtains the color difference of the sensor array. The result of the color change analysis visualizes the RGB difference with color display images and numerical values created as excel files. The colorimetric sensor array was fabricated as a 6x6 array guided by an array template using PEEK polymer which is not reactive to organic solvents. The dimension of the sensor array substrate was 30 mm(l)x 30 mm(w)x 4 mm(h) and the diameter of each hole for an individual sensor is 4 mm. The each spots of sensors was created by hydrogel matrices that can provide uniform color signals. The white LED was illuminated from the bottom of the template with a constant light source. The housing unit was equipped within the system to place the sensor array and the smartphone camera in a fixed position and to prevent the light from outside disturbing the intrinsic signals from the sensor array. This housing unit enables acquiring the sensor array images under the same conditions as the camera settings. Figure 1 shows the structure of the colorimetric sensor array reader system. The housing unit is a closed gas chamber and has a 50 mL of room to enable gas reaction experiments. The gas chamber has inlet and outlet so that gas can be injected and color change image can be obtained at each reaction time. The smartphone camera (Samsung Galaxy 7) was perpendicularly positioned over the sensor array at the fixed distance of 6 cm. An image of the color sensor array is acquired before injecting the target gas into gas chamber and the images of the color sensor array are temporally obtained while the target gas is injected at a constant volumetric rate. The structure of the smartphone application for image analysis is divided into the procedure of selecting the color sensor array, finding the array position, acquiring RGB color information and analyzing difference of color information as shown in Figure 2. After selecting images with a certain time lapse experiment to be analyzed, the application will automatically find the position of the sensor array. An image thresholding algorithm in openCV library was used to locate the sensor array and shape 36 sensor spots. The spots can be detected individually and 111 pixel region of the center of each spot can be calculated by HoughCircle algorithm in openCV library as shown in Figure 3. The 36 analysis areas obtained by the algorithm overlap the images obtained before and after the target gas was injected to take the RGB value in those areas. After obtaining the RGB median values of each sensor array images, the application can analyze the RGB deviation value of the image before the gas injection and the time-lapse image after the gas injection. This RGB difference shows that the degree of color change of the sensor array, when the color array sensor responds to the molecules of target gas. The analyzed results of the time-lapse response of the color sensor array exposed to 50 ppm of propionic acid are shown in Figure 4. This program could extract the median, mean and standard deviation of the RGB colors of all spots in the senor array images into an excel file and save the virtual array images of the RGB differences. In conclusion, we implemented the application program that analyzes color difference of colorimetric sensor array. The smartphone camera generates image files by measuring the color array sensor at each elapsed time points. The android application analyzes the acquired images and simply calculates the color change of the color array. We envision that the useful color sensor array reader system allows the color sensor array to be easily recorded reaction of gas molecules through the analyzed RGB difference values. This work was supported by the Technology Innovation Program (Grant No. 10077599) funded by the Ministry of Trade, Industry & Energy (MOTIE, Korea) [1] Anal. Chem. 2006, 78, 3591-3600 [2] L. Shen, J.A. Hagen, I. Papautsky, Point-of-care colorimetric detection with a smartphone, Lab Chip 12 (2012) 4240–4243. Figure 1