Institute of Medical Physics and Radiation Protection Mittelhessen University of Applied Sciences Giessen Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
AGAnpreet Ghotra
Anpreet Ghotra
HKHeather Lynne Kosakowski
Heather Lynne Kosakowski
ATAtsushi Takahashi
Atsushi Takahashi
RERobin Etzel
Robin Etzel
MMMarkus W. May
Markus W. May
BKBoris Keil
Boris Keil
Purpose: Functional magnetic resonance imaging (fMRI) during infancy poses challenges due to practical, methodological, and analytical considerations. The aim of this study was to implement a hardware‐related approach to increase subject compliance for fMRI involving awake infants. To accomplish this, we designed, constructed, and evaluated an adaptive 32‐channel array coil.Methods: To allow imaging with a close‐fitting head array coil for infants aged 1‐18 months, an adjustable head coil concept was developed. The coil setup facilitates a half‐seated scanning position to improve the infant’s overall scan compliance. Earmuff compartments are integrated directly into the coil housing to enable the usage of sound protection without losing a snug fit of the coil around the infant’s head. The constructed array coil was evaluated from phantom data using bench‐level metrics, signal‐to‐noise ratio (SNR) performances, and accelerated imaging capabilities for both in‐plane and simultaneous multislice (SMS) reconstruction methodologies. Furthermore, preliminary fMRI data were acquired to evaluate the in vivo coil performance.Results: Phantom data showed a 2.7‐fold SNR increase on average when compared with a commercially available 32‐channel head coil. At the center and periphery regions of the infant head phantom, the SNR gains were measured to be 1.25‐fold and 3‐fold, respectively. The infant coil further showed favorable encoding capabilities for undersampled k‐space reconstruction methods and SMS techniques.Conclusions: An infant‐friendly head coil array was developed to improve sensitivity, spatial resolution, accelerated encoding, motion insensitivity, and subject tolerance in pediatric MRI. The adaptive 32‐channel array coil is well‐suited for fMRI acquisitions in awake infants.

23 May 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MMMarkus W. May
Markus W. May
SHSam-Luca J.D. Hansen
Sam-Luca J.D. Hansen
MMMirsad Mahmutovic
Mirsad Mahmutovic
ASAlina Scholz
Alina Scholz
NKNicolas Kutscha
Nicolas Kutscha
BKBoris Keil
Boris Keil
Purpose: To extend the coverage of brain coil arrays to the neck and cervical–spine region to enable combined head and neck imaging at 7 Tesla (T) ultra‐high field MRI.Methods: The coil array structures of a 64‐channel receive coil and a 16‐channel transmit coil were merged into one anatomically shaped close‐fitting housing. Transmit characteristics were evaluated in a B1+‐field mapping study and an electromagnetic model. Receive SNR and the encoding capability for accelerated imaging were evaluated and compared with a commercially available 7 T brain array coil. The performance of the head–neck array coil was demonstrated in human volunteers using high‐resolution accelerated imaging.Results: In the brain, the SNR matches the commercially available 32‐channel brain array and showed improvements in accelerated imaging capabilities. More importantly, the constructed coil array improved the SNR in the face area, neck area, and cervical spine by a factor of 1.5, 3.4, and 5.2, respectively, in regions not covered by 32‐channel brain arrays at 7 T. The interelement coupling of the 16‐channel transmit coil ranged from −14 to −44 dB (mean = −19 dB, adjacent elements <−18 dB). The parallel 16‐channel transmit coil greatly facilitates B1+ field shaping required for large FOV neuroimaging at 7 T.Conclusion: This new head–neck array coil is the first demonstration of a device of this nature used for combined full‐brain, head–neck, and cervical‐spine imaging at 7 T. The array coil is well suited to provide large FOV images, which potentially improves ultrahigh field neuroimaging applications for clinical settings.

27 September 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
GRGabriel Ramos‐Llordén
Gabriel Ramos‐Llordén
DPDaniel J. Park
Daniel J. Park
JKJohn E. Kirsch
John E. Kirsch
ASAlina Scholz
Alina Scholz
BKBoris Keil
Boris Keil
SHSusie Y. Huang
Susie Y. Huang

25 February 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
ASAlina Scholz
Alina Scholz
RERobin Etzel
Robin Etzel
MMMarkus W May
Markus W May
MMMirsad Mahmutovic
Mirsad Mahmutovic
QTQiyuan Tian
Qiyuan Tian
BKBoris Keil
Boris Keil
In vivo diffusion-weighted magnetic resonance imaging is limited in signal-to-noise-ratio (SNR) and acquisition time, which constrains spatial resolution to the macroscale regime. Ex vivo imaging, which allows for arbitrarily long scan times, is critical for exploring human brain structure in the mesoscale regime without loss of SNR. Standard head array coils designed for patients are sub-optimal for imaging ex vivo whole brain specimens. The goal of this work was to design and construct a 48-channel ex vivo whole brain array coil for high-resolution and high b -value diffusion-weighted imaging on a 3T Connectome scanner. The coil was validated with bench measurements and characterized by imaging metrics on an agar brain phantom and an ex vivo human brain sample. The two-segment coil former was constructed for a close fit to a whole human brain, with small receive elements distributed over the entire brain. Imaging tests including SNR and G-factor maps were compared to a 64-channel head coil designed for in vivo use. There was a 2.9-fold increase in SNR in the peripheral cortex and a 1.3-fold gain in the center when compared to the 64-ch head coil. The 48-channel ex vivo whole brain coil also decreases noise amplification in highly parallel imaging, allowing acceleration factors of approximately one unit higher for a given noise amplification level. The acquired diffusion-weighted images in a whole ex vivo brain specimen demonstrate the applicability of the developed coil for high-resolution and high b -value diffusion-weighted ex vivo brain MRI studies.

2 August 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
GRGabriel Ramos-Llordén
Gabriel Ramos-Llordén
RLRodrigo A. Lobos
Rodrigo A. Lobos
TKTae Hyung Kim
Tae Hyung Kim
QTQiyuan Tian
Qiyuan Tian
TWThomas Witzel
Thomas Witzel
SHSusie Y. Huang
Susie Y. Huang
Diffusion MRI (dMRI) of whole, intact, fixed postmortem human brain at high spatial resolution serves as key bridging technology for 3D mapping of structural connectivity and tissue microstructure at the mesoscopic scale. Ex vivo dMRI offers superior spatial resolution compared to in vivo dMRI but comes with its own technical challenges due to the significantly reduced T2 relaxation times and decreased diffusivity incurred by tissue fixation. The altered physical properties of fixed tissue necessitate the use of alternative acquisition strategies to preserve SNR and achieve sufficient diffusion weighting. Multi-shot or segmented 3D echo planar imaging (EPI) sequences have been used to shorten echo times (TEs) with reduced distortions from field inhomogeneity and eddy currents on small-bore MR scanners and have been adopted for high b-value dMRI of ex vivo whole human brain specimens. The advent of stronger gradients on human MRI scanners has led to improved image quality and a wider range of diffusion-encoding parameters for dMRI but at the cost of more severe eddy currents that result in spatial and temporal variations in the background magnetic field, which cannot be corrected for using standard vendor-provided ghost correction solutions. In this work, we show that conventional ghost correction techniques based on navigators and linear phase correction may be insufficient for EPI sequences using strong diffusion-sensitizing gradients in ex vivo dMRI experiments, resulting in orientationally biased dMRI estimates. This previously unreported problem is a critical roadblock in any effort to leverage scanners with ultra-high gradients for high-precision mapping of human neuroanatomy at the mesoscopic scale. We propose an advanced reconstruction method based on structured low-rank matrix modeling that reduces the ghosting substantially. We show that this method leads to more accurate and reliable dMRI metrics, as exemplified by diffusion tensor imaging and high angular diffusion imaging analyses in distributed neuroanatomical areas of fixed whole human brain specimens. Our findings advocate for the use of advanced reconstruction techniques for recovering unbiased metrics from ex vivo dMRI acquisitions and represent a crucial step toward making full use of strong diffusion-encoding gradients for neuroscientific studies seeking to study brain structure at multiple spatial scales.