This note reports observations of the change of stiffness of human mesenchymal stem cells (hMSCs) with the progress of cell death as measured by AFM. hMSC with impaired membrane, dead and viable cells were labelled with Annexin V and Propidium Iodide after 24h cold storage, followed by AFM measurement and Young's modulus of cells was derived. Viable hMSCs have a Young's modulus (E) in the range of 0.81-1.13kPa and consistent measurement was observed when different measurement locations were chosen. E of cells with partially impaired membrane was 0.69±0.17kPa or in the range of 2.04-4.74kPa, depending upon the measurement locations. With the loss of membrane integrity, though there was no variation on measured E between different locations, a mixed picture of cell stiffness was observed as indicated by cells with E as low as 0.09±0.03kPa, in a mid-range of 4.62±0.67kPa, and the highest of up to 48.98±19.80kPa. With the progress of cell death, the highest stiffness was noticed for cells showing a more granular appearance; also the lowest stiffness for cells with vacuole appearance. Findings from this study indicate that cell stiffness is significantly altered with the progress of cell death.
24 July 2008 in Journal of the Optical Society of America B
Whispering gallery modes (WGMs) in dielectric microcylinders are investigated numerically as sensitive probes of the surrounding medium, for applications in chemical sensing and biosensing. We consider a geometry where WGMs are exited via frustrated total internal reflection from a planar dielectric substrate, as reported in recent experiments. The optical coupling between the substrate and the cylinder yields a WGM broadening exponentially decreasing with increasing distance between the cylinder and the substrate. We also consider a separation layer between the substrate and the cylinder that results in a WGM broadening and shift depending on the index mismatch between the layer and the surrounding medium, and find that Q values are possible for a mismatch in the few percent range. For biosensing applications we calculate the effect of single and multiple cylinder-shaped particles of different sizes attached to the cylinder surface to simulate biological analytes. We find not only WGM shifts but also broadenings and splittings acting as sensitive indicators of different properties of the analytes. In particular, in the case of a single particle, both particle size and refractive index can be determined from the WGM shift and broadening, opening the perspective to a new modality of biosensing applicable to single objects such as viruses or bacteria. In the multiparticle case, the results are statistically analyzed in terms of their surface coverage.
In a recent publication [3rd International Conference on Surface Metrology, Annecy, France, 2012, p. 1] it was shown that surface roughness measurements made using a focus variation microscope (FVM) are influenced by surface tilt. The effect appears to be most significant when the surface has microscale roughness () that is sufficient to provide a diffusely scattered signal that is comparable in magnitude to the specular component. This paper explores, from first principles, image formation using the focus variation method. With the assumption of incoherent scattering, it is shown that the process is linear and the 3D point spread characteristics and transfer characteristics of the instrument are well defined. It is argued that for the case of microscale roughness and through the objective illumination, the assumption of incoherence cannot be justified and more rigorous analysis is required. Using a foil model of surface scattering, the images that are recorded by a FVM have been calculated. It is shown that for the case of through-the-objective illumination at small tilt angles, the signal quality is degraded in a systematic manner. This is attributed to the mixing of specular and diffusely reflected components and leads to an asymmetry in the -space representation of the output signals. It is shown that by using extra-aperture illumination or tilt angles greater than the acceptance angle of aperture (such that the specular component is lost), the incoherent assumption can be justified once again. The work highlights the importance of using ring-light illumination and/or polarizing optics, which are often available as options on commercial instruments, as a means to mitigate or prevent these effects.
23 May 2012 in Journal of The Royal Society Interface
In the current study, the mechanical and hypothermic damage induced by vibration and cold storage on human mesenchymal stem cells (hMSCs) stored at 2–8°C was quantified by measuring the total cell number and cell viability after exposure to vibration at 50 Hz (peak acceleration 140 m s−2 and peak displacement 1.4 mm), 25 Hz (peak acceleration 140 m s−2, peak displacement 5.7 mm), 10 Hz (peak acceleration 20 m s−2, peak displacement 5.1 mm) and cold storage for several durations. To quantify the viability of the cells, in addition to the trypan blue exclusion method, the combination of annexin V-FITC and propidium iodide was applied to understand the mode of cell death. Cell granularity and a panel of cell surface markers for stemness, including CD29, CD44, CD105 and CD166, were also evaluated for each condition. It was found that hMSCs were sensitive to vibration at 25 Hz, with moderate effects at 50 Hz and no effects at 10 Hz. Vibration at 25 Hz also increased CD29 and CD44 expression. The study further showed that cold storage alone caused a decrease in cell viability, especially after 48 h, and also increased CD29 and CD44 and attenuated CD105 expressions. Cell death would most likely be the consequence of membrane rupture, owing to necrosis induced by cold storage. The sensitivity of cells to different vibrations within the mechanical system is due to a combined effect of displacement and acceleration, and hMSCs with a longer cold storage duration were more susceptible to vibration damage, indicating a coupling between the effects of vibration and cold storage.
20 October 2009 in Biotechnology and Bioengineering
In this work a new phenomenological model of growth of cartilage tissue cultured in a rotating bioreactor is developed. It represents an advancement of a previously derived model of deposition of glycosaminoglycan (GAG) in engineered cartilage by (i) introduction of physiological mechanisms of proteoglycan accumulation in the extracellular matrix (ECM) as well as by correlating (ii) local cell densities and (iii) tissue growth to the ECM composition. In particular, previously established predictions and correlations of local oxygen concentrations and GAG synthesis rates are extended to distinguish cell secreted proteoglycan monomers free to diffuse in cell surroundings and outside from the engineered construct, from large aggrecan molecules, which are constrained within the ECM and practically immovable. The model includes kinetics of aggregation, that is, transformation of mobile GAG species into immobile aggregates as well as maintenance of the normal ECM composition after the physiological GAG concentration is reached by incorporation of a product inhibition term. The model also includes mechanisms of the temporal evolution of cell density distributions and tissue growth under in vitro conditions. After a short initial proliferation phase the total cell number in the construct remains constant, but the local cell distribution is leveled out by GAG accumulation and repulsion due to negative molecular charges. Furthermore, strong repulsive forces result in expansion of the local tissue elements observed macroscopically as tissue growth (i.e., construct enlargement). The model is validated by comparison with experimental data of (i) GAG distribution and leakage, (ii) spatial‐temporal distributions of cells, and (iii) tissue growth reported in previous works. Validation of the model predictive capability—against a selection of measured data that were not used to construct the model—suggests that the model successfully describes the interplay of several simultaneous processes carried out during in vitro cartilage tissue regeneration and indicates that this approach could also be attractive for application in other tissue engineering systems. Biotechnol. Bioeng. 2010. 105: 842–853.
Bragg scattering of polaritons by a coherent acoustic wave is mediated and strongly enhanced by the exciton states resonant with the acoustic and optic fields in the intraband and interband transitions, respectively. In this case, in contrast with conventional acousto-optics, the resonantly enhanced Bragg spectra reveal the multiple orders of diffracted light. For polaritons in GaAs microcavities driven by a surface acoustic wave of and the main acoustically induced band gap can be as large as and the Bragg replicas up to can be observed.