Giuseppe Carlo Alp Caridi

Giuseppe Carlo Alp Caridi

Auto-generated profile, based on publicly available information

Giuseppe Carlo Alp Caridi

Institute of Fluid Mechanics and Heat Transfer, TU Wien , 1060 Wien

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2015 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
FSFulvio Scarano
Fulvio Scarano
SGSina Ghaemi
Sina Ghaemi
GCGiuseppe Carlo Alp Caridi
Giuseppe Carlo Alp Caridi
JBJohannes Bosbach
Johannes Bosbach
UDUwe Dierksheide
Uwe Dierksheide
ASAndrea Sciacchitano
Andrea Sciacchitano
The flow-tracing fidelity of sub-millimetre diameter helium-filled soap bubbles (HFSB) for low-speed aerodynamics is studied. The main interest of using HFSB in relation to micron-size droplets is the large amount of scattered light, enabling larger-scale three-dimensional experiments by tomographic PIV. The assessment of aerodynamic behaviour closely follows the method proposed in the early work of Kerho and Bragg (Exp Fluids 50:929–948, 1994) who evaluated the tracer trajectories around the stagnation region at the leading edge of an airfoil. The conclusions of the latter investigation differ from the present work, which concludes sub-millimetre HFSB do represent a valid alternative for quantitative velocimetry in wind tunnel aerodynamic experiments. The flow stagnating ahead of a circular cylinder of 25 mm diameter is considered at speeds up to 30 m/s. The tracers are injected in the free-stream and high-speed PIV, and PTV are used to obtain the velocity field distribution. A qualitative assessment based on streamlines is followed by acceleration and slip velocity measurements using PIV experiments with fog droplets as a term of reference. The tracing fidelity is controlled by the flow rates of helium, liquid soap and air in HFSB production. A characteristic time response, defined as the ratio of slip velocity and the fluid acceleration, is obtained. The feasibility of performing time-resolved tomographic PIV measurements over large volumes in aerodynamic wind tunnels is also studied. The flow past a 5-cm-diameter cylinder is measured over a volume of 20 × 20 × 12 cm3 at a rate of 2 kHz. The achieved seeding density of <0.01 ppp enables resolving the Kármán vortices, whereas turbulent sub-structures cannot be captured.

1 January 2020 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
EBEdoardo Burzio
Edoardo Burzio
FBF. Bersani
F. Bersani
GCG.C.A. Caridi
G.C.A. Caridi
RVR. Vesipa
R. Vesipa
LRL. Ridolfi
L. Ridolfi
CMC. Manes
C. Manes
Hydrodynamic Cavitation (HC) is considered as a promising water-disinfection technique. Due to the enormous complexity of the physical and chemical processes at play, research on HC reactors is usually carried out following an empirical approach. Surprisingly, past experimental studies have never been designed on dimensional-analysis principles, which makes it difficult to identify the key processes controlling the problem, isolate their effects and scale up the results from laboratory to full-scale scenarios. The present paper overcomes this issue and applies the principles of dimensional analysis to identify the major non-dimensional parameters controlling disinfection efficacy in classical HC reactors, namely orifice plates. On the basis of this analysis, it presents results from a new set of experiments, which were designed to isolate mainly the effects of the so-called cavitation number (σv). Experimental data confirm that the disinfection efficacy of orifice plates increases with decreasing σv. Finally, in order to discuss the significance of the results presented herein and frame the scope of future research, the present paper provides an overview of the drawbacks associated with dimensional analysis within the context of HC.

19 November 2016 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
GCGiuseppe Carlo Alp Caridi
Giuseppe Carlo Alp Caridi
DRDaniele Ragni
Daniele Ragni
ASAndrea Sciacchitano
Andrea Sciacchitano
FSFulvio Scarano
Fulvio Scarano
A new system for large-scale tomographic particle image velocimetry in low-speed wind tunnels is presented. The system relies upon the use of sub-millimetre helium-filled soap bubbles as flow tracers, which scatter light with intensity several orders of magnitude higher than micron-sized droplets. With respect to a single bubble generator, the system increases the rate of bubbles emission by means of transient accumulation and rapid release. The governing parameters of the system are identified and discussed, namely the bubbles production rate, the accumulation and release times, the size of the bubble injector and its location with respect to the wind tunnel contraction. The relations between the above parameters, the resulting spatial concentration of tracers and measurement of dynamic spatial range are obtained and discussed. Large-scale experiments are carried out in a large low-speed wind tunnel with 2.85 × 2.85 m2 test section, where a vertical axis wind turbine of 1 m diameter is operated. Time-resolved tomographic PIV measurements are taken over a measurement volume of 40 × 20 × 15 cm3, allowing the quantitative analysis of the tip-vortex structure and dynamical evolution.

13 October 2016 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
JSJan F. G. Schneiders
Jan F. G. Schneiders
GCGiuseppe C. A. Caridi
Giuseppe C. A. Caridi
ASAndrea Sciacchitano
Andrea Sciacchitano
FSFulvio Scarano
Fulvio Scarano
The instantaneous volumetric pressure in the near-wake of a truncated cylinder is measured by use of tomographic particle tracking velocimetry (PTV) using helium-filled soap bubbles (HFSB) as tracers. The measurement volume is several orders of magnitude larger than that reported in tomographic experiments dealing with pressure from particle image velocimetry (PIV). The near-wake of a truncated cylinder installed on a flat plate (Re D = 3.5 × 104) features both wall-bounded turbulence and large-scale unsteady flow separation. The instantaneous pressure is calculated from the time-resolved 3D velocity distribution by invoking the momentum equation. The experiments are conducted simultaneously with surface pressure measurements intended for validation of the technique. The study shows that time-averaged pressure and root-mean-squared pressure fluctuations can be accurately measured both in the fluid domain and at the solid surface by large-scale tomographic PTV with HFSB as tracers, with significant reduction in manufacturing complexity for the wind-tunnel model and circumventing the need to install pressure taps or transducers. The measurement over a large volume eases the extension toward the free-stream regime, providing a reliable boundary condition for the solution of the Poisson equation for pressure. The work demonstrates, in the case of the flow past a truncated cylinder, the use of HFSB tracer particles for pressure measurement in air flows in a measurement volume that is two orders of magnitude larger than that of conventional tomographic PIV.

2 August 2024 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
VGVlad Giurgiu
Vlad Giurgiu
GCGiuseppe Carlo Alp Caridi
Giuseppe Carlo Alp Caridi
MPMarco De Paoli
Marco De Paoli
ASAlfredo Soldati
Alfredo Soldati
The motion, settling, and dispersion of microplastics in the ocean are determined by their rotational dynamics. We present experiments on elongated, large aspect ratio, and mildly curved plastic fibers slightly longer than the Kolmogorov length scale. Exploiting their uniquely identifiable three-dimensional orientation, we perform original optical Lagrangian investigations and provide a set of homogeneous data on their rotation rates around their longitudinal axis: spinning rate, and transversal axes: tumbling rates, which we explain in the context of the general features of turbulence.

30 August 2017 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
GCGiuseppe Carlo Alp Caridi
Giuseppe Carlo Alp Caridi
ASAndrea Sciacchitano
Andrea Sciacchitano
FSFulvio Scarano
Fulvio Scarano
Velocity measurements within the core of high-swirl vortices are often hampered by heavier-than-air particle tracers being centrifuged outside the vortex core region. The use of neutrally buoyant and lighter-than-air tracers is investigated to aim at homogeneous tracers concentration in air flow experiments dealing with high-swirl vortices using particle image velocimetry. Helium-filled soap bubbles (HFSB) of sub-millimeter diameter are employed as flow tracers. Their density is controlled varying the relative amount of helium and soap solution composing the bubbles. The dynamics of HFSB and micro-size droplets is modeled within a Lamb–Oseen vortex to retrieve the order of magnitude of the tracers slip velocity. A positive radial drift for heavier-than-air tracers leads to an empty vortex core. In contrast, the concentration at the vortex axis is expected to increase for lighter than air tracers. Experiments are conducted on a sharp-edged slender delta wing at 20° incidence. At chosen chord-based Reynolds numbers of 2 × 105 and 6 × 105, a stable laminar vortex is formed above the delta wing. Laser sheet visualization is used to inspect the spatial concentration of tracers. A comparison is made between micron-sized fog droplets and HFSB tracers in the nearly neutrally buoyant condition. Stereo-PIV measurements with fog droplets return a systematically underestimated axial velocity distribution within the vortex core due to drop-out of image cross-correlation signal. The nearly neutrally buoyant HFSB tracers appear to maintain a homogeneous spatial concentration and yield cross-correlation signal up to the vortex axis. The resulting velocity measurements are in good agreement with literature data.