Stefan Ataman

Stefan Ataman

Auto-generated profile, based on publicly available information

Stefan Ataman

Extreme Light Infrastructure - Nuclear Physics (ELI-NP), ‘Horia Hulubei’ National R&D Institute for Physics and Nuclear Engineering (IFIN-HH), 30 Reactorului Street, 077125 Măgurele, jud. Ilfov, Romania

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2018 in Reports on Progress in Physics
Verified
Journal Article
Closed access
PDF file
SGS Gales
S Gales
KTK A Tanaka
K A Tanaka
DBD L Balabanski
D L Balabanski
FNF Negoita
F Negoita
DSD Stutman
D Stutman
NZN V Zamfir
N V Zamfir
The European Strategy Forum on Research Infrastructures (ESFRI) has selected in 2006 a proposal based on ultra-intense laser fields with intensities reaching up to 10 22 –10 23 W cm −2 called ‘ELI’ for Extreme Light Infrastructure. The construction of a large-scale laser-centred, distributed pan-European research infrastructure, involving beyond the state-of-the-art ultra-short and ultra-intense laser technologies, received the approval for funding in 2011–2012. The three pillars of the ELI facility are being built in Czech Republic, Hungary and Romania. The Romanian pillar is ELI-Nuclear Physics (ELI-NP). The new facility is intended to serve a broad national, European and International science community. Its mission covers scientific research at the frontier of knowledge involving two domains. The first one is laser-driven experiments related to nuclear physics, strong-field quantum electrodynamics and associated vacuum effects. The second is based on a Compton backscattering high-brilliance and intense low-energy gamma beam (<20 MeV), a marriage of laser and accelerator technology which will allow us to investigate nuclear structure and reactions as well as nuclear astrophysics with unprecedented resolution and accuracy. In addition to fundamental themes, a large number of applications with significant societal impact are being developed. The ELI-NP research centre will be located in Măgurele near Bucharest, Romania. The project is implemented by ‘Horia Hulubei’ National Institute for Physics and Nuclear Engineering (IFIN-HH). The project started in January 2013 and the new facility will be fully operational by the end of 2019. After a short introduction to multi-PW lasers and multi-MeV brilliant gamma beam scientific and technical description of the future ELI-NP facility as well as the present status of its implementation of ELI-NP, will be presented. The science and examples of societal applications at reach with these electromagnetic probes with much improved performances provided at this new facility will be discussed with a special focus on day-one experiments and associated novel instrumentation.

30 October 2018 in Physical Review A
Verified
Journal Article
Closed access
PDF file
SAStefan Ataman
Stefan Ataman
APAnca Preda
Anca Preda
RIRadu Ionicioiu
Radu Ionicioiu
Interferometry is a widely used technique for precision measurements in both classical and quantum contexts. One way to increase the precision of phase measurements, for example, in a Mach-Zehnder interferometer (MZI), is to use high-intensity lasers. In this paper we study the phase sensitivity of a MZI in two detection setups (difference intensity detection and single-mode intensity detection) and for three input scenarios (coherent, double coherent, and coherent plus squeezed vacuum). For the coherent and double coherent input, both detection setups can reach the quantum Cramér-Rao bound, although at different values of the optimal phase shift. The double coherent input scenario has the unique advantage of changing the optimal phase shift by varying the input power ratio.

8 June 2018 in Physical Review A
Verified
Journal Article
Closed access
PDF file
SAStefan Ataman
Stefan Ataman
In this paper we propose an all-optical vacuum birefringence experiment and evaluate its feasibility for various scenarios. Many petawatt-class lasers became operational and many more are expected to enter operation in the near future, therefore unprecedented electromagnetic fields (EL∼1014–1015 V/m and intensities IL∼1021–1023W/cm2) will become available for experiments. In our proposal a petawatt-class laser disturbs the quantum vacuum and creates a delay in a counterpropagating probe laser beam. Placing this delayed beam in one arm of a Mach-Zehnder interferometer (MZI), allows the measurement of the vacuum refraction coefficient via a phase shift. Coherent as well as squeezed light are both considered and the minimum phase sensitivity evaluated. We show that using existing technology with some moderately optimistic assumptions, at least part of the discussed scenarios are feasible for a vacuum birefringence detection experiment.

13 December 2019 in Physical Review A
Verified
Journal Article
Open access
PDF file
SAStefan Ataman
Stefan Ataman
We address in this work the phase sensitivity of a Mach-Zehnder interferometer with Gaussian input states. A squeezed-coherent plus squeezed vacuum input state allows us to unambiguously determine the optimal phase-matching conditions in order to maximize the quantum Fisher information. Realistic detection schemes are described and their performance compared with respect to the quantum Cramér-Rao bound. The core of this paper discusses in detail the most general Gaussian input state, without any a priori parameter restrictions. Prioritizing the maximization of various terms in the quantum Fisher information has the consequence of imposing the input phase-matching conditions. We discuss in detail when each scenario yields an optimal performance. Realistic detection scenarios are also considered and their performance compared to the theoretical optimum. The impact of the beam splitter types employed on the optimum phase-matching conditions is also discussed. We find a number of potentially interesting advantages of these states over the coherent plus squeezed vacuum input case.

6 July 2020 in Physical Review A
Verified
Journal Article
Closed access
PDF file
SAStefan Ataman
Stefan Ataman
In this paper we reconsider the single-parameter quantum Fisher information (QFI) and compare it with the two-parameter one. We find simple relations connecting the single-parameter QFI (both in the asymmetric and symmetric phase shift cases) to the two-parameter Fisher matrix coefficients. Following some clarifications about the role of an external phase [ Phys. Rev. A 85, 011801(R) (2012)], the single-parameter QFI and its overoptimistic predictions have been disregarded in the literature. We show in this paper that both the single- and two-parameter QFI have physical meaning, and their predicted quantum Cramér-Rao bounds are often attainable with the appropriate experimental setup. Moreover, we give practical situations of interest in quantum metrology, where the phase sensitivities of a number of input states approach the quantum Cramér-Rao bound induced by the single-parameter QFI, outperforming the two-parameter QFI.

10 January 2022 in Physical Review A
Verified
Journal Article
Closed access
PDF file
SAStefan Ataman
Stefan Ataman
In this paper we provide the answer to the following question: given an arbitrary pure input state and a general, unbalanced, Mach-Zehnder interferometer, what transmission coefficient of the first beam splitter maximizes the quantum Fisher information (QFI)? We consider this question for both single- and two-parameter QFI, or, in other words, with or without having access to an external phase reference. We give analytical results for all involved scenarios. It turns out that, for a large class of input states, the balanced (50:50) scenario yields the optimal two-parameter QFI; however, this is far from being a universal truth. When it comes to the single-parameter QFI, the balanced scenario is rarely the optimal one and an unbalanced interferometer can bring a significant advantage over the balanced case. We also state the condition imposed upon the input state so that no metrological advantage can be exploited via an external phase reference. Finally, we illustrate and discuss our assertions through a number of examples, including both Gaussian and non-Gaussian input states.