Rafael Garcia

Rafael Garcia

Auto-generated profile, based on publicly available information

Rafael Garcia

Department of Orthopedic Surgery, University of Minnesota, Minneapolis, MN, USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2025 in International Journal of Spine Surgery
Verified
Journal Article
Closed access
PDF file
RGRafael Garcia
Rafael Garcia
KOKari Odland
Kari Odland
JSJonathan Sembrano
Jonathan Sembrano
Background Obesity is often associated with worse outcomes after lumbar fusion surgery, but its impact on patient-reported outcomes in spondylolisthesis remains unclear. This study assesses the effect of body mass index (BMI) on outcomes for degenerative and isthmic spondylolisthesis patients undergoing lumbar fusion. Methods We conducted a retrospective analysis of 86 patients with low-grade lumbar degenerative and isthmic spondylolisthesis, categorized by BMI into nonobese (<30 kg/m²), obesity class I (30.0–34.9 kg/m²), obesity class II (35.0–39.9 kg/m²), and obesity class III (≥40.0 kg/m²). Outcomes were measured using the visual analog scale (VAS) for pain and the Oswestry Disability Index (ODI) at baseline and 12 months postoperatively. Statistical analyses included a 1-way analysis of variance, Bonferroni post hoc comparisons, and Kruskal-Wallis tests. Results Significant disability improvements (mean ODI improvement: 15.6 points, P < 0.001) were observed across all BMI categories, while pain improvements were less pronounced (mean VAS improvement: 2.1 points, P < 0.001). Nonobese and class II patients maintained improvements at 12 months. Degenerative spondylolisthesis patients showed better ODI outcomes compared with isthmic patients (P = 0.019), while VAS outcomes were similar (P = 0.251). Conclusion Lumbar fusion results in significant disability reduction across BMI categories, with sustained improvements in nonobese and obesity class II patients. These findings suggest that obesity should not be a contraindication for lumbar fusion in well-selected patients, as meaningful improvements can be achieved, particularly in disability outcomes. Clinical Relevance Clinically, this supports a more individualized approach to surgical candidacy, emphasizing functional goals and symptom burden over BMI alone, thereby promoting equitable access to care and helping guide preoperative counseling and shared decision-making. Level of Evidence 3.

8 February 2025 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
RGRafael Garcia
Rafael Garcia
KOKari Odland
Kari Odland
PLPaul Lender
Paul Lender
DPDavid Polly
David Polly

21 July 2025 in Pain Medicine
Verified
Journal Article
Closed access
RARafael Garcia Andujar
Rafael Garcia Andujar
KOKari Odland
Kari Odland
CHCale Hendricks
Cale Hendricks
NHNathan Hendrickson
Nathan Hendrickson
Background: Psychosocial factors such as pain catastrophizing, fear-avoidance behaviors, and depression are associated with poor outcomes after spine surgery. Cognitive behavioral therapy (CBT) is a structured psychological intervention shown to improve coping, reduce disability, and mitigate pain in musculoskeletal conditions. However, its role and implementation in surgical spine populations remain variable. Objective: This scoping review aims to evaluate how CBT has been applied in spine surgery settings and synthesize findings related to patient-reported outcomes, opioid use, and rehabilitation trajectories. Methods: A comprehensive search was conducted across Ovid Medline, PubMed, and Scopus. Inclusion criteria were (1) adult spine surgery population, (2) CBT-based intervention (pre- or postoperatively), and (3) reporting on functional, psychological, or opioid-related outcomes. Seven eligible studies were included. Results: CBT was delivered preoperatively in 3 studies and postoperatively in 4 studies. Commonly measured outcomes included ODI, PCS, FABQ, and VAS. Across studies, CBT was associated with reduced disability, improved pain coping behaviors, and accelerated early recovery. Telehealth delivery was feasible and effective in some contexts. However, session frequency, provider type, and mode of delivery varied substantially. Long-term benefit beyond 6-12 months was inconsistent. Conclusion: CBT appears to be a valuable adjunct to spine surgery recovery, particularly for high-risk patients. Yet, heterogeneity in implementation highlights the need for standardized protocols and long-term outcome evaluation.

29 May 2025 in North American Spine Society Journal (NASSJ)
Verified
Journal Article
Open access
CHCale J. Hendricks
Cale J. Hendricks
DPDavid W. Polly
David W. Polly
AAAshley M. Abbott
Ashley M. Abbott
YYYaqoub Y. Yusuf
Yaqoub Y. Yusuf
RGRafael A. Garcia
Rafael A. Garcia
AEArin M. Ellingson
Arin M. Ellingson
Sacroiliac joint (SIJ) fusion is a common procedure for SIJ pain and dysfunction. Traditional threaded screws offer limited bony integration, prompting the development of additively manufactured, porous implants aimed at enhancing osseointegration. However, data on their insertional mechanics and pullout strength, especially in revision scenarios, remain sparse. This study aimed to investigate the influence of bone density, tapping, and implant size on re-insertional torque and pullout strength. Mechanical testing was conducted in accordance with ASTM F543, using 10 and 20 PCF polyurethane foam blocks to simulate low and normal-density bone, respectively. A 10 × 35 mm screw fusion device served as the control. For subsequent tests, the 10 × 35 mm screw was removed, and various diameters (10, 11.5, 13.5 mm) and lengths (35, 40, 45 mm) were reinserted under 2 conditions: direct and with tapping. The maximum and final insertional torque, as well as the maximum pullout force, were measured. ANOVA techniques with pairwise comparison and Pearson correlation tests were performed (α = 0.05). Significant effects and interactions were observed for implant size, bone density, and tapping. Larger implant diameter and length were associated with significantly greater insertional torque and pullout strength compared to controls, though excessively large diameters yielded diminishing returns in normal-density bone. Independent of size and tapping, normal-density bone consistently demonstrated greater insertional torque (929.1 ± 6.5 vs. 235.0 ± 6.5N·cm) and pullout strength (1,331.2 ± 14.8 vs. 457.3 ± 14.6 N) than low-density bone (p < .001). Independent of size, tapping improved insertional torque (+33.9%; p < .001) and pullout strength (+108.4%; p < .001) in normal-density bone but reduced pullout strength in low-density bone (−22.4%; p < .001). Final insertional torque strongly correlated with pullout strength (r = 0.946, p < .001). Our findings provide evidence-based insight for optimizing implant selection and surgical technique in revision SIJ fusion procedures using screw fusion devices. Particularly, it is emphasized that both implant dimensions and patient-specific bone quality must be considered to achieve stable and successful outcomes.

7 October 2026 in International Journal of Spine Surgery
Verified
Journal Article
Open access
PDF file
TKThomas Kroymann
Thomas Kroymann
TPTodd Pottinger
Todd Pottinger
RGRafael Garcia
Rafael Garcia
KOKari Odland
Kari Odland
CLCharles Ledonio
Charles Ledonio
DPDavid Polly
David Polly
Background S1 pedicle screw loosening remains a recognized complication after lumbosacral fusion, but its incidence in shorter-segment constructs for degenerative lumbar disease remains incompletely defined. Methods Adults who underwent lumbosacral fusion, including S1 pedicle fixation, for degenerative lumbar pathology between 2021 and 2024 were retrospectively reviewed. Included patients had at least 12 months of radiographic follow-up. Screw loosening was defined as a radiolucent zone of at least 1 mm around the S1 screw and graded using a modified Shimizu-Lenke scheme (grades 0, 1, 2A, 2B, and 3). Results A total of 68 patients met inclusion criteria, with a mean age of 58.6 ± 14.4 years. The overall incidence of S1 screw loosening was 4.4% (3/68), with a mean time to screw loosening of 43.0 ± 9.2 weeks postoperatively. Interbody devices were placed at L5 to S1 in 66/68 (97.1%), most commonly via transforaminal lumbar interbody fusion approach (48/68, 70.6%), followed by anterior lumbar interbody fusion (13/68, 19.1%) and oblique lateral interbody fusion (5/68, 7.4%). Most constructs were short-segment fusions, and most patients received interbody support. Because loosening events were uncommon, analyses of potential associations with bone quality, construct characteristics, and alignment parameters should be interpreted as exploratory. Conclusion In this single-institution cohort, S1 pedicle screw loosening after degenerative short-segment lumbosacral fusion was uncommon. The findings support the need for larger studies with longer follow-up to clarify the contributions of bone quality, alignment, and fixation strategy to loosening risk. Clinical Relevance Variability of clinical presentation of S1 screw loosening highlight the need for further investigation into the relationship between S1 screw loosening and clinical outcomes. Level of Evidence 3.