Lingfeng Li

Lingfeng Li

Auto-generated profile, based on publicly available information

Lingfeng Li

Beijing Key Laboratory of Optimized Design for Modern Agricultural Equipment, College of Engineering, China Agricultural University, Beijing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2022 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
JZJun Zou
Jun Zou
LLLingfeng Li
Lingfeng Li
YZYuan Zhuang
Yuan Zhuang
CWChanghui Wang
Changhui Wang
MZMing Zhang
Ming Zhang
JHJianjun HE
Jianjun HE
Ultra-compact on-chip spectrometers with high resolution and large bandwidth play a crucial role in miniaturized spectroscopic analysis systems. Here we present a novel polarization-insensitive micro-spectrometer with high resolution and large bandwidth based on a ( N + 3) × ( N + 3) arrayed waveguide grating (AWG) on silicon-on-insulator (SOI) platform. The proposed AWG can be viewed as two same 3 × N AWGs with each one having three input waveguides with channel spacing of 4/3 Δ λ and N output waveguides with channel spacing of Δ λ . The three input waveguides are time division multiplexed, i.e., they are excited one by one in sequence. As a result, combining all spectral responses of each input, a micro-spectrometer with channel wavelength spacing enhanced to one-third Δ λ and channel number enlarged to 3 × ( N – 2) is achieved, only using N output channels. The polarization diversity scheme is utilized to address the polarization sensitive issue of silicon nano-waveguide, i.e., the AWG operates at a counter-propagating manner to process each polarization, respectively. In experiment, we demonstrate a micro-spectrometer with 81 channels and channel wavelength spacing of 0.4 nm by employing a 32 × 32 AWG on the SOI platform. The footprint of the fabricated micro-spectrometer is only 1.1 × 2.35 mm 2 . Experimental results show that the spectrometer has on-chip losses ranging from –5.8 to –2.5 dB, noise level of better than 17 dB, polarization dependent wavelength shift (PD λ ) of less than 0.07 nm and polarization dependent loss (PDL) of less than 1.5 dB, for all 81 wavelength channels. The resolution of the micro-spectrometer is mainly dependent on the 3-dB bandwidth of each channel and is simulated to be ∼0.65 nm. The proposed ultracompact and polarization insensitive high-resolution on-chip spectrometer provides a very promising approach for achieving miniaturized spectrometer-on-a-chip with good performance for applications such as in fiber Bragg grating (FBG) sensor readout unit and optical waveguide sensor systems.

11 March 2024 in Optics & Laser Technology
Verified
Journal Article
Closed access
LLLingfeng Li
Lingfeng Li
HXHeng-Na Xiong
Heng-Na Xiong
XLXuan Li
Xuan Li
XCXiaofei Chen
Xiaofei Chen
CWChanghui Wang
Changhui Wang
JZJun Zou
Jun Zou

14 October 2022 in Sugar Tech
Verified
Journal Article
Closed access
PDF file
ZDZhengliang Ding
Zhengliang Ding
MSMa Shaochun
Ma Shaochun
XZXiaodong Zhang
Xiaodong Zhang
WLWenpeng Liang
Wenpeng Liang
LLLingfeng Li
Lingfeng Li
CSChenyang Su
Chenyang Su

1 January 2023
Verified
Conference Paper
Closed access
PDF file
LLLingfeng Li
Lingfeng Li
SMShaochun Ma
Shaochun Ma
XZXi Zeng
Xi Zeng
CSChenyang Su
Chenyang Su
YLYechen Li
Yechen Li