Angel Lai

Angel Lai

Auto-generated profile, based on publicly available information

Angel Lai

Division of Cardiology, Department of Medicine and Therapeutics (C.S K.., J.X., A.L., K.K., B.P.Y., A.P.L., Y.L.), The Chinese University of Hong Kong

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
MTMark T K Tam
Mark T K Tam
YCYuet-Wong Cheng
Yuet-Wong Cheng
JCJoseph Y S Chan
Joseph Y S Chan
CCChin-Pang Chan
Chin-Pang Chan
AAAlex C K Au
Alex C K Au
BYBryan P Yan
Bryan P Yan
Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated. Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied. A retrospective cohort of consecutive 139 Micra implants was used to compare the PCT evolution. High PCT was defined as ≥1.5 V, using a pulse width of 0.4 ms for Aveir and 0.24 ms for Micra. Excellent PCT was defined as ≤0.5 V at the respective pulse width. Among the 123 consecutive Aveir VR implant attempts, 122 (99.2%) were successful. The majority were of advanced age (mean 79.7) and small body size (mean BSA 1.60). Two patients (1.6%) experienced complications, including one pericardial effusion after device reposition and one intraoperative device dislodgement. Eighty-eight patients reached a 3-month follow-up. Aveir 3-month PCT was correlated with impedance at mapping (P = 0.015), tether mode (P < 0.001), end-of-procedure (P < 0.001), and mapping PCT (P = 0.035), but not with PCTs after fixation (P > 0.05). Tether mode impedance >470 ohms had 88% sensitivity and 71% specificity in predicting excellent 3-month PCT. Although it is more common for Aveir to have high PCT at end of procedure (11.5% for Aveir and 2.2% for Micra, P = 0.004), the rate at 3 months was similar (2.3% for Aveir and 3.1% for Micra, P = 1.000). Aveir VR demonstrated satisfactory performance in this high-risk cohort. Pacing thresholds tend to improve to a greater extent than Micra after implantation. The PCT after fixation, even after a waiting period, has limited predictive value for the chronic threshold. Low-mapping PCT and high intraoperative impedance predict chronic low PCT. Aveir VR pacing threshold tended to improve after implant, while Micra stayed the same. Intraoperative impedance is a good predictor for chronic threshold, while intraoperative threshold was not.

11 September 2025 in Infectious Diseases and Therapy
Verified
Journal Article
Open access
PDF file
HCHoi K. Cheng
Hoi K. Cheng
ALAngel Lai
Angel Lai
MKMaxwell Kwok
Maxwell Kwok
BYBryan P. Yan
Bryan P. Yan
EPEllen Poon
Ellen Poon
Introduction The high mortality of Coronavirus Disease 2019 (COVID-19) highlights the need for safe and effective antiviral treatment. Small molecular antivirals (remdesivir, molnupiravir, nirmatrelvir/ritonavir) and immunomodulators (baricitinib, tocilizumab) have been developed or repurposed to suppress viral replication and ameliorate cytokine storms, respectively. Despite U.S. Food and Drug Administration (FDA) approval, serious cardiovascular adverse events (CVAEs) may not be apparent in initial trials. Methods A retrospective analysis of CVAEs linked to five World Health Organization (WHO) recommended COVID-19 therapies was conducted using the WHO VigiBase database from March 2020 to July 2023. Adjusted reporting odds ratios (aROR) with 95% confidence intervals (CI) were calculated to assess CVAE risks. Results A total of 276,631 AEs were reported to be associated with COVID-19, of which 13,091 were classified as cardiovascular events. Remdesivir was associated with significantly increased odds of CVAEs, particularly bradycardia (aROR 2.4, 95% CI 2.28–2.52). In contrast, nirmatrelvir/ritonavir and molnupiravir showed reduced CVAEs odds. Among immunomodulators, baricitinib was associated with increased CVAEs risk (aROR 2.31, 95% CI 2.07–2.59), with deep vein thrombosis being the most prominent (aROR 45.34, 95% CI 34.89–58.9), accounting for 38.8% of reported study cases in the database. Also, CVAEs odds were higher during the Omicron period compared to pre-Omicron period. Conclusions These findings highlight the importance of continued pharmacovigilance and suggest potential CV safety differences among COVID-19 immunomodulators. Since tocilizumab and baricitinib are similarly indicated for severe patients with COVID-19, further clinical trials are warranted to explore whether tocilizumab represents a safer alternative to baricitinib for these patients. Insights from this study may guide future antiviral repurposing and pandemic preparedness strategies.

30 July 2025 in European Heart Journal
Verified
Journal Article
Open access
BYBryan Ping-Yen Yan
Bryan Ping-Yen Yan
KKKevin Ka-Ho Kam
Kevin Ka-Ho Kam
ALAngel Lai
Angel Lai
CNCanice Lok-Hang Ng
Canice Lok-Hang Ng
NCNgai-Yin Chan
Ngai-Yin Chan
GTGuangMing Tan
GuangMing Tan

1 December 2025 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
KSKent Chak-Yu So
Kent Chak-Yu So
DWDarren Walters
Darren Walters
KMKrissada Meemook
Krissada Meemook
JXJianqiang Xu
Jianqiang Xu
ALAngel Lai
Angel Lai
SSShih-Hsien Sung
Shih-Hsien Sung

28 October 2025 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
GTGuangMing Tan
GuangMing Tan
ALAngel Lai
Angel Lai
MWMartin C.S. Wong
Martin C.S. Wong
JLJames Y.W. Lau
James Y.W. Lau
BYBryan P.Y. Yan
Bryan P.Y. Yan