1 April 2014 in Journal of Biomechanics
1 January 2016 in Journal of Rehabilitation Research and Development
Prosthetic alignment is an important factor in the overall fit and performance of a lower-limb prosthesis. However, the association between prosthetic alignment and control strategies used by persons with transfemoral amputation to coordinate the movement of a passive prosthetic knee is poorly understood. This study investigated the biomechanical response of persons with transfemoral amputation to systematic perturbations in knee joint alignment during a level walking task. Quantitative gait data were collected for three alignment conditions: bench alignment, 2 cm anterior knee translation (ANT), and 2 cm posterior knee translation (POST). In response to a destabilizing alignment perturbation (i.e., the ANT condition), participants significantly increased their early-stance hip extension moment, confirming that persons with transfemoral amputation rely on a hip extensor strategy to maintain knee joint stability. However, participants also decreased the rate at which they loaded their prosthesis, decreased their affected-side step length, increased their trunk flexion, and maintained their prosthesis in a more vertical posture at the time of opposite toe off. Collectively, these results suggest that persons with transfemoral amputation rely on a combination of strategies to coordinate stance-phase knee flexion. Further, comparatively few significant changes were observed in response to the POST condition, suggesting that a bias toward posterior alignment may have fewer implications in terms of stance-phase, knee joint control.
12 September 2018 in PLOS ONE
Many Service members and Veterans with lower-limb amputations have the potential for high function and the desire to resume physically demanding occupations that require them to carry heavy loads (e.g., military service, firefighters, farmers, ranchers, construction workers). However, it is currently unclear which prosthetic feet best accommodate heavy load carriage while also providing good overall function and mobility during unweighted activities. The main objective of this study was to investigate the ability of currently available prosthetic ankle-foot systems to accommodate weighted walking by examining the mechanical characteristics (i.e., forefoot stiffness) and dynamic function (i.e., rocker radius, effective foot length ratio, and late-stance energy return) of prosthetic feet designed for high activity users. Load versus deflection curves were obtained for nine prosthetic ankle-foot systems using a servohydraulic test frame and load cell. Effective roll-over shape characteristics and late-stance energy return measures were then obtained using quantitative gait analysis for three users with unilateral, transtibial amputation. Results from mechanical and dynamic testing showed that although forefoot stiffness varied across the nine feet investigated in this study, changes measured in roll-over shape radius and effective foot length ratio were relatively small in response to weighted walking. At the same time, prosthetic feet with more compliant forefoot keel structures appeared to provide more late-stance energy return compared to feet with stiffer forefoot keel structures. These results suggest that prosthetic ankle-foot systems with compliant forefoot keel structures may better accommodate weighted walking by reducing the metabolic cost of physically demanding activities. However, to more fully understand the biomechanical and functional implications of these results, other factors, such as the residual-limb strength of the user and the overall stiffness profile of the prosthetic foot, should also be considered.
30 April 2019 in PLOS ONE
Peripheral neuropathy may cause loss of sensory information from plantar cutaneous mechanoreceptors that is important for balance control and falls management. The current study investigated short-term effects of using Walkasins, an external lower-limb sensory neuroprosthesis, on clinical outcomes of balance and gait in persons who reported peripheral neuropathy and balance problems. The device replaces lost plantar sensation with tactile balance information that modulates cutaneous mechanoreceptors above the ankle where sensation is intact. Thirty-one male community-dwelling Veterans, 56–84 years old with insensate feet and balance problems participated. Initial Functional Gait Assessment, gait speed, and 4-Stage Balance Test outcomes were assessed. After initial assessment, subjects were randomly assigned to either wearing Walkasins turned ON, or OFF, and outcomes were re-assessed following a set of standardized balance exercises. Following a one-hour rest and washout period, treatments were crossed-over between groups and a third outcomes assessment was performed. Before cross-over, 10 of 15 subjects in the ON-then-OFF group improved their Functional Gait Assessment score by at least four points, the Minimal Clinically Important Difference, compared to 5 of 16 in the OFF-then-ON group. After cross-over, 7 of 16 subjects in the OFF-then-ON group improved by at least four points versus 2 of 15 in the ON-then-OFF group. ON treatment was associated with a Functional Gait Assessment improvement of 4.4 ± 3.7 points versus 1.5 ± 1.2 for the OFF treatment (p<0.01). Overall, Functional Gait Assessment scores changed from 15.2 ± 4.8 at initial assessment to 21.1 ± 5.2 after final assessment (p<0.001). At the end of the two treatment sessions, 16 of the 31 individuals had improved their Functional Gait Assessment score beyond 23, indicating normal fall-risk status. Future studies should investigate long-term benefits of the device to reduce fall risk and actual falls in patients with peripheral neuropathy and balance problems.
26 September 2018 in PLOS ONE
Previous work suggests that to restore postural stability for individuals with lower-limb amputation, ankle-foot prostheses should be designed with a flat effective rocker shape for standing. However, most commercially available ankle-foot prostheses are designed with a curved effective rocker shape for walking. To address the demands of both standing and walking, we designed a novel bimodal ankle-foot prosthesis that can accommodate both functional modes using a rigid foot plate and an ankle that can lock and unlock. The primary objective of this study was to determine if the bimodal ankle-foot system could improve various aspects of standing balance (static, dynamic, and functional) and mobility in a group of Veterans with lower-limb amputation (n = 18). Standing balance was assessed while subjects completed a series of tests on a NeuroCom Clinical Research System (NeuroCom, a Division of Natus, Clackamas, OR), including a Sensory Organization Test, a Limits of Stability Test, and a modified Motor Control Test. Few statistically significant differences were observed between the locked and unlocked ankle conditions while subjects completed these tests. However, in the absence of visual feedback, the locked bimodal ankle appeared to improve static balance in a group of experienced lower-limb prosthesis users whose PLUS-M mobility rating was higher than approximately 73% of the sample population used to develop the PLUS-M survey. Given the statistically significant increase in mean equilibrium scores between the unlocked and locked conditions (p = 0.004), future testing of this system should focus on new amputees and lower mobility users (e.g., Medicare Functional Classification Level K1 and K2 prosthesis users). Furthermore, commercial implementation of the bimodal ankle-foot system should include a robust control system that can automatically switch between modes based on the user’s activity.