Wayne Homer Slade

Wayne Homer Slade

Auto-generated profile, based on publicly available information

Wayne Homer Slade

Sequoia Scientific, Inc., 2700 Richards Road, Suite 107, Bellevue, Washington 98005, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2010 in Journal of Atmospheric and Oceanic Technology
Verified
Journal Article
Closed access
WSWayne H. Slade
Wayne H. Slade
EBEmmanuel Boss
Emmanuel Boss
GDGiorgio Dall’olmo
Giorgio Dall’olmo
MLM. Rois Langner
M. Rois Langner
JLJames Loftin
James Loftin
TWToby K. Westberry
Toby K. Westberry
Optical sensors have distinct advantages when used in ocean observatories, autonomous platforms, and on vessels of opportunity, because of their high-frequency measurements, low power consumption, and the numerous established relationships between optical measurements and biogeochemical variables. However, the issues of biofouling and instrument stability over time remain complicating factors when optical instruments are used over periods longer than several days. Here, a method for obtaining calibration-independent measurements of spectral particle absorption and attenuation is presented. Flow-through optical instrumentation is routinely diverted through a large–surface area 0.2-μm cartridge filter, allowing for the calculation of particle optical properties by differencing temporally adjacent filtered and whole water samples. This approach yields measurements that are independent of drift in instrument calibration. The method has advantages not only for coastally moored deployments, but also for applications in optically clear waters where uncertainties in instrument calibration can be a significant part of the signal measured. The differencing technique is demonstrated using WET Labs (Philomath, Oregon) ac-9 and ac-s multi- and hyperspectral absorption and attenuation meters. For the ac-s sensor, a correction scheme is discussed that utilizes the spectral shape of water absorption in the near-infrared to improve the accuracy of temperature and scattering-corrected spectra. Flow-through particulate absorption measurements are compared with discrete filter-pad measurements and are found to agree well (R2 = 0.77; rmse = 0.0174 m−1).

1 September 2013 in Methods in Oceanography
Verified
Journal Article
Open access
EBEmmanuel Boss
Emmanuel Boss
MPMarc Picheral
Marc Picheral
TLThomas Leeuw
Thomas Leeuw
ACAlison Chase
Alison Chase
EKEric Karsenti
Eric Karsenti
HCHerve Claustre
Herve Claustre

10 December 2017 in Journal of Geophysical Research: Oceans
Verified
Journal Article
Open access
PDF file
ACAlison Chase
Alison Chase
EBEmmanuel Boss
Emmanuel Boss
Ivan CetinicIvan Cetinic
Ivan Cetinic
WSW. Slade
W. Slade
Phytoplankton community composition in the ocean is complex and highly variable over a wide range of space and time scales. Able to cover these scales, remote‐sensing reflectance spectra can be measured both by satellite and by in situ radiometers. The spectral shape of reflectance in the open ocean is influenced by the particles in the water, mainly phytoplankton and covarying nonalgal particles. We investigate the utility of in situ hyperspectral remote‐sensing reflectance measurements to detect phytoplankton pigments by using an inversion algorithm that defines phytoplankton pigment absorption as a sum of Gaussian functions. The inverted amplitudes of the Gaussian functions representing pigment absorption are compared to coincident High Performance Liquid Chromatography measurements of pigment concentration. We determined strong predictive capability for chlorophylls a, b, c1+c2, and the photoprotective carotenoids. We also tested the estimation of pigment concentrations from reflectance‐derived chlorophyll a using global relationships of covariation between chlorophyll a and the accessory pigments. We found similar errors in pigment estimation based on the relationships of covariation versus the inversion algorithm. An investigation of spectral residuals in reflectance data after removal of chlorophyll‐based average absorption spectra showed no strong relationship between spectral residuals and pigments. Ultimately, we are able to estimate concentrations of three chlorophylls and the photoprotective carotenoid pigments, noting that further work is necessary to address the challenge of extracting information from hyperspectral reflectance beyond the information that can be determined from chlorophyll a and its covariation with other pigments.

26 January 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
EBEmmanuel Boss
Emmanuel Boss
WSWayne H. Slade
Wayne H. Slade
MBM. Behrenfeld
M. Behrenfeld
GDG. Dall'Olmo
G. Dall'Olmo
The beam attenuation serves as a proxy for particulate matter and is a key parameter in visibility algorithms for the aquatic environment. It is well known, however, that the beam attenuation is a function of the acceptance angle of the transmissometer used to measure it. Here we compare eight different transmissometers with four different acceptance angles using four different deployment strategies and sites, and find that their mean attenuation values differ markedly and in a consistent way with instrument acceptance angle: smaller acceptance angles provide higher beam attenuation values. This difference is due to variations in scattered light collected with different acceptance angles and is neither constant nor easy to parameterize. Variability (in space or time) in the ratios of beam attenuations measured by two different instruments correlates, in most cases, with the particle size parameter (as expected from Mie theory), but this correlation is often weak and can be the opposite of expectations based on particle size changes. We recommended careful consideration of acceptance angle in applications of beam transmission data especially when comparing data from different instruments.

12 August 2015 in Applied Optics
Verified
Journal Article
Open access
PDF file
WSWayne Homer Slade
Wayne Homer Slade
EBEmmanuel Boss
Emmanuel Boss
Measurements of the particulate beam attenuation coefficient at multiple wavelengths in the ocean typically exhibit a power law dependence on wavelength, and the slope of that power law has been related to the slope of the particle size distribution (PSD), when assumed to be a power law function of particle size. Recently, spectral backscattering coefficient measurements have been made using sensors deployed at moored observatories, on autonomous underwater vehicles, and even retrieved from space-based measurements of remote sensing reflectance. It has been suggested that these backscattering measurements may also be used to obtain information about the shape of the PSD. In this work, we directly compared field-measured PSD with multispectral beam attenuation and backscattering coefficients in a coastal bottom boundary later. The results of this comparison demonstrated that (1) the beam attenuation spectral slope correlates with the average particle size as suggested by theory for idealized particles and PSD; and (2) measurements of spectral backscattering also contain information reflective of the average particle size in spite of large deviations of the PSD from a spectral power law shape.

21 May 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
EBEmmanuel Boss
Emmanuel Boss
WSWayne Slade
Wayne Slade
PHPaul Hill
Paul Hill
Marine aggregates, agglomerations of particles and dissolved materials, are an important particulate pool in aquatic environments, but their optical properties are not well understood. To improve understanding of the optical properties of aggregates, two related studies are presented. In the first, an in situ manipulation experiment is described, in which beam attenuation of undisturbed and sheared suspensions are compared. Results show that in the sheared treatment bulk particle size decreases and beam attenuation increases, consistent with the hypothesis that a significant fraction of mass in suspension is contained in fragile aggregates. Interestingly, the magnitude of increase in beam attenuation is less than expected if the aggregates are modeled as solid spheres. Motivated by this result, a second study is presented, in which marine aggregates are modeled to assess how the beam attenuation of aggregates differs from that of their constituent particles and from solid particles of the same mass. The model used is based on that of Latimer [Appl. Opt. 24, 3231 (1985)] and mass specific attenuation is compared with that based on homogeneous and solid particles, the standard model for aquatic particles. In the modeling we use recent research relating size and solid fraction of aquatic aggregates. In contrast with Mie theory, this model provides a rather size-insensitive mass specific attenuation for most relevant sizes. This insensitivity is consistent with the observations that mass specific beam-attenuation of marine particles is in the range 0.2-0.6m2/gr despite large variability in size distribution and composition across varied aquatic environments.