1 July 2024 in Nature Materials
1 April 2026 in Energy & Environmental Science
A bipolar membrane electrolyzer coupling bicarbonate electrolysis with formaldehyde oxidation directly produces syngas (H 2 : CO = 1) at 1.7 V and 200 mA cm −2 with 200% combined Faradaic efficiency.
9 August 2024 in ECS Meeting Abstracts
The world of electrochemical devices has witnessed remarkable progress in recent years, with particular emphasis on the development and advancement of bipolar membranes (BPMs). This progress has predominantly centered around BPM applications within membrane electrode assembly (MEA) systems, encompassing technologies such as fuel cells and electrolyzers. The exploration of BPM in these MEA systems has allowed for an almost complete elimination of the BPM overpotential for water dissociation and has dramatically changed the playing field and viability of BPM. This rapid advancement in understanding BPM fundamentals has in part come from the commercially available and universally utilized lab-scale electrolyzer/fuel cell systems. These devices have allowed labs around the world to focus on finite aspects of the BPM without being slowed by the debates of varying test stands. With the development of advanced, MEA optimized BPM and increased understanding of BPM fundamentals, the time is right to embark on the next phase of BPM research. This next phase looks to expand the use of BPM to non-MEA systems, including CO2 sequestration systems, electrodialysis, brine remediation, organic acid/base production, and more. These non-MEA systems present unique challenges and opportunities that demand innovation. To begin the expansion of advanced BPM to non-MEA applications we present here a lab-scale BPM electrodialysis system that allows for small membrane sizes and full system monitoring. This system is cheap to build, highly modular, easy to operate, and allows for a wide range of non-MEA systems to be explored. With this, we hope to speed up the translation of advanced, MEA optimized BPM to non-MEA applications.
11 July 2025 in ECS Meeting Abstracts
Recent interest in hydrogen fuel cells motivates development of bipolar membranes (BPMs) as a method for electrochemical hydrogen generation. BPMs are ionic heterojunctions valuable for their ability to establish a pH gradient with a basic anode and an acidic cathode. Between the cation and anion exchange membranes (CEM & AEM), metal-oxide nanoparticles (NPs) facilitate the water dissociation reaction to generate the hydrogen gas. We focus on characterizing the morphology of BPMs. BPM performance depends on the details of the composition and thickness of the dissociation layer. We are studying under what fabrication and use conditions nanoparticles in this central layer migrate into the CEM or AEM membranes. We first investigated CEM / AEM interfaces without catalyst nanoparticles as produced using solvent processing. SEM and Time of Flight Secondary Mass Spectroscopy (ToF-SIMS) imaging revealed interdiffusion of SPEEK8 (CEM) and PiperION (AEM) when the junction is heated in the presence of DMF. The result is a trilayer structure of SPEEK8, SPEEK8 mixed with PiperION, and PiperION, wherein the mixed layer is ~ 15 µm thick. A similar trilayer sample was observed when SnO2 nanoparticles were sprayed onto PiperION in a grid pattern prior to depositing SPEEK8 from DMF solvent followed by heating. Moreover, this fabrication method distributes the SnO2 nanoparticles throughout the trilayer morphology rather than confining the catalyst to the mixed layer or a thin coating, as is typically assumed. Despite this unexpected nanoscale morphology, these BPM show good electrochemical and adhesive performance. To explore the fundamentals of nanoparticle diffusion within CEMs and AEMs, we constructed diffusion couples in which a polymer-nanoparticle composite is sandwiched between thick polymer films. In this study the polymer in the nanocomposite and the thick layers is Nafion and the nanoparticles are TiO2 NPs (radii 5, 30 or 100 nm). Upon annealing in dry conditions, the nanoparticles diffuse from the nanocomposite into the thick layers and we measure in 3D the evolution of the concentration profile using ToF-SIMS. From integrated profiles, we extract the nanoparticle diffusion coefficient. After completing these measurements in the dry conditions, we’ll explore nanoparticle diffusion in hydrated samples.
9 August 2024 in ECS Meeting Abstracts
Bipolar membranes (BPMs) have experienced a renaissance, owing to their proposed use in membrane electrode assembly (MEA) systems. MEA systems encompass technologies such as fuel cells and electrolyzers, where the BPM allows for fine pH control at the electrodes and helps to prevent ion-crossover that may lead to lower system efficiencies and fouling of the system. The exploration of MEA systems has significantly expanded our fundamental understanding of BPM functionality and limits, setting the stage for future advancements in BPM applications. Beyond MEA systems, BPMs have been seen in a wide array of technologies such as CO2 sequestration systems, electrodialysis, brine remediation, organic acid/base production, and more. These applications all present unique stressor to the BPM that prevent the direct translation of advanced, MEA optimized BPM to these non-MEA systems. Initial investigations into transferring advanced BPM to non-MEA applications have found issues with membrane delamination at scale and a need for system specific catalyst optimization. However, the fundamentals learned from MEA systems translate well and can be used to inform advancements of BPM in these non-MEA systems. Here we present initial findings and proposed solutions for durability issues when optimizing advanced BPM for application in BPM electrodialysis.