1 January 2013 in The Scientific World Journal
Whether two vertical semicircular canals can receive thermal stimuli remains controversial. This study examined the caloric response in the three semicircular canals to the clinical hot caloric test using the finite element method. The results of the developed model showed the horizontal canal (HC) cupula maximally deflected to the utricle side by approximately 3 μm during the hot supine test. The anterior canal cupula began to receive the caloric stimuli about 20 s after the HC cupula, and it maximally deflected to the canal side by 0.55 μm. The posterior canal cupula did not receive caloric stimuli until approximately 40 s after the HC cupula, and it maximally deflected to the canal side by 0.34 μm. Although the endolymph flow and the cupular deformation change with respect to the head position during the test, the supine test ensures the maximal caloric response in the HC, but no substantial improvement for the responses of the two vertical canals was observed. In conclusion, while the usual supine test is the optimum test for evaluating the functions of the inner ear, more irrigation time is needed in order to effectively clinically examine the vertical canals.
14 January 2025 in Journal of Translational Medicine
Parkinson’s Disease (PD) is a neurodegenerative disorder, and eye movement abnormalities are a significant symptom of its diagnosis. In this paper, we developed a multi-task driven by eye movement in a virtual reality (VR) environment to elicit PD-specific eye movement abnormalities. The abnormal features were subsequently modeled by using the proposed deep learning algorithm to achieve an auxiliary diagnosis of PD. We recruited 114 PD patients and 125 healthy controls and collected their eye-tracking data in a VR environment. Participants completed a series of specific VR tasks, including gaze stability, pro-saccades, anti-saccades, and smooth pursuit. After the tasks, eye movement features were extracted from the behaviors of fixations, saccades, and smooth pursuit to establish a PD diagnostic model. The performance of the models was evaluated through cross-validation, revealing a recall of 97.65%, an accuracy of 92.73%, and a receiver operator characteristic area under the curve (ROC-AUC) of 97.08% for the proposed model. We extracted PD-specific eye movement features from the behaviors of fixations, saccades, and smooth pursuit in a VR environment to create a model with high accuracy and recall for PD diagnosis. Our method provides physicians with a new auxiliary tool to improve the prognosis and quality of life of PD patients.
21 May 2020 in Biomechanics and Modeling in Mechanobiology
15 April 2021 in Scientific Reports
The vestibular receptor of cupula acts an important role in maintaining body balance. However, the cupula buried in the semicircular canals (SCCs) will be destroyed if it is detached from the relevant environment. The mechanical properties of human cupula still remain ambiguous. In this paper, we explored the cupula responses changing with temperature by experiments and numerical simulation of SCCs model. We obtained 3 volunteers’ nystagmus induced by constant angular acceleration when the temperature of volunteers’ SCCs was 36 °C and 37 °C respectively. The slow-phase velocity of 3 volunteers decreased by approximately 3°/s when the temperature of SCCs reduced by 1 °C, which corresponded to the reduction of cupula deformation by 0.3–0.8 μm in the numerical model. Furthermore, we investigated the effects of the variation of endolymphatic properties induced by temperature reduction on cupula deformation through numerical simulation. We found that the decrease of cupula deformation was not caused by the change of endolymphatic properties, but probably by the increase of cupula’s elastic modulus. With the temperature reducing by 1 °C, the cupula’s elastic modulus may increase by 6–20%, suggesting that the stiffness of cupula is enhanced. This exploration of temperature characteristic of human cupula promotes the research of alleviating vestibular diseases.
19 September 2022 in Journal of Oncology
Background. To construct and validate a deep learning cluster from whole slide images (WSI) for depicting the immunophenotypes and functional heterogeneity of the tumor microenvironment (TME) in patients with bladder cancer (BLCA) and to explore an artificial intelligence (AI) score to explore the underlying biological pathways in the developed WSI cluster. Methods. In this study, the WSI cluster was constructed based on a deep learning procedure. Further rerecognition of TME features in pathological images was applied based on a neural network. Then, we integrated the TCGA cohort and several external testing cohorts to explore and validate this novel WSI cluster and a corresponding quantitative indicator, the AI score. Finally, correlations between the AI cluster (AI score) and classical BLCA molecular subtypes, immunophenotypes, functional heterogeneity, and potential therapeutic method in BLCA were assessed. Results. The WSI cluster was identified associated with clinical survival ( ) and was proved as an independent predictor ( ), which could also predict the immunology and the clinical significance of BLCA. Rerecognition of pathological images established a robust 3-year survival prediction model (with an average classification accuracy of 86%, AUC of 0.95) for BLCA patients combining TME features and clinical features. In addition, an AI score was constructed to quantify the underlying logic of the WSI cluster ( ). Finally, we hypothesized that high AI score shapes an immune-hot TME in BLCA. Thus, treatment options including immune checkpoint blockade (ICB), chemotherapy, and ERBB therapy can be used for the treatment of BLCA patients in WSI cluster1 (high AI score subtype). Conclusions. In general, we showed that deep learning can predict prognosis and may aid in the precision medicine for BLCA directly from H&E histology, which is more economical and efficient.