Vincent Studer

Vincent Studer

Auto-generated profile, based on publicly available information

Vincent Studer

Laboratoire de Photonique et de Nanostructures, CNRS, Route de Nozay, 91460 Marcoussis, France

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2012 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
VSVincent Studer
Vincent Studer
JBJérome Bobin
Jérome Bobin
MCMakhlad Chahid
Makhlad Chahid
HMHamed Shams Mousavi
Hamed Shams Mousavi
ECEmmanuel Candes
Emmanuel Candes
MDMaxime Dahan
Maxime Dahan
The mathematical theory of compressed sensing (CS) asserts that one can acquire signals from measurements whose rate is much lower than the total bandwidth. Whereas the CS theory is now well developed, challenges concerning hardware implementations of CS-based acquisition devices—especially in optics—have only started being addressed. This paper presents an implementation of compressive sensing in fluorescence microscopy and its applications to biomedical imaging. Our CS microscope combines a dynamic structured wide-field illumination and a fast and sensitive single-point fluorescence detection to enable reconstructions of images of fluorescent beads, cells, and tissues with undersampling ratios (between the number of pixels and number of measurements) up to 32. We further demonstrate a hyperspectral mode and record images with 128 spectral channels and undersampling ratios up to 64, illustrating the potential benefits of CS acquisition for higher-dimensional signals, which typically exhibits extreme redundancy. Altogether, our results emphasize the interest of CS schemes for acquisition at a significantly reduced rate and point to some remaining challenges for CS fluorescence microscopy.

14 March 2004 in Nature Biotechnology
Verified
Journal Article
Closed access
PDF file
JHJong Wook Hong
Jong Wook Hong
VSVincent Studer
Vincent Studer
GHGiao Hang
Giao Hang
WAW French Anderson
W French Anderson
SQStephen R Quake
Stephen R Quake

22 November 2007 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
DBDenis Bartolo
Denis Bartolo
GDGuillaume Degré
Guillaume Degré
PNPhilippe Nghe
Philippe Nghe
VSVincent Studer
Vincent Studer
We present how to make and assemble micro-patterned stickers (µPS) to construct high performance plastic microfluidic devices in a few minutes. We take advantage of soft UV imprint techniques to tailor the geometry, the mechanical properties, and the surface chemistry of 2D and 3D microfluidic circuits. The resulting microfluidic stickers substantially overcome the actual performance of the very popular PDMS devices for a wide range of applications, while sharing their celebrated fast and easy processing. To highlight the intrinsic advantages of this method, three important applications are detailed: (i) we show that both aqueous and organic droplets can be produced and stored in stickers without any specific surface coating. (ii) We report on the outstanding pressure resistance of the µPS, which open the way to the transport of viscous complex fluids. (iii) Finally, a simple design strategy is proposed to generate complex flow patterns in interconnected stacks of µPS.

1 January 2004 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
VSVincent Studer
Vincent Studer
GHGiao Hang
Giao Hang
APAnna Pandolfi
Anna Pandolfi
MOMichael Ortiz
Michael Ortiz
WAW. French Anderson
W. French Anderson
SQStephen R. Quake
Stephen R. Quake
Using basic physical arguments, we present a design and method for the fabrication of microfluidic valves using multilayer soft lithography. These on-off valves have extremely low actuation pressures and can be used to fabricate active functions, such as pumps and mixers in integrated microfluidic chips. We characterized the performance of the valves by measuring both the actuation pressure and flow resistance over a wide range of design parameters, and compared them to both finite element simulations and alternative valve geometries.

9 August 2004 in The Analyst
Verified
Journal Article
Closed access
PDF file
VSVincent Studer
Vincent Studer
APAnne Pépin
Anne Pépin
YCYong Chen
Yong Chen
AAArmand Ajdari
Armand Ajdari
We have built a dedicated lab on a chip to study the performance of an integrated electrokinetic micropump, driven by a low voltage AC signal. This micropump consists of an array of interdigitated electrodes and is here integrated in a microfluidic loop. We demonstrate that this device can pump continuously and reproducibly electrolyte solutions of low to moderate ionic strength. The pumping speed reaches up to 500 µm s−1 in 20 µm deep and 100 µm wide channels with a driving signal in the 1–10 kHz range and an amplitude of only a few volts. In addition, we have observed an interesting reversal of the pumping direction at higher frequencies (50–100 kHz). Our device permits a systematic and automated exploration of the influence of the ionic strength thanks to an integrated micromixer.

11 May 2015 in Nature Methods
Verified
Journal Article
Closed access
RGRemi Galland
Remi Galland
GGGianluca Grenci
Gianluca Grenci
AAAjay Aravind
Ajay Aravind
VVVirgile Viasnoff
Virgile Viasnoff
VSVincent Studer
Vincent Studer
JSJean-Baptiste Sibarita
Jean-Baptiste Sibarita