30 January 2026 in IEEE Transactions on Instrumentation and Measurement
The absolute positioning accuracy of industrial robotic arms is crucial for advancing manufacturing applications such as automated assembly. This study presents a Hybrid Mapping Polynomial Neural Network based on Particle Swarm Optimization (PSO-HMPNN) for industrial robot calibration. The proposed approach integrates independent mapping neural networks with polynomial residual interaction neural modules to enhance error compensation capabilities, while employing the PSO algorithm to optimize neural network weights and avoid local optima. Experimental validation was performed on two distinct datasets (Dataset ABB and Dataset HSR) using ABB IRB120 and HSR JR680 robot, with performance compared against eight state-of-the-art calibration algorithms (M2-M9). Results demonstrate that PSO-HMPNN consistently achieved the lowest error metrics across both datasets. On the primary dataset (Dataset ABB), it reached a Mean Absolute Error (MAE) of 0.36mm, a Root Mean Square Error (RMSE) of 0.42mm, and a Maximum Error (MAX) of 0.92mm. This represents improvements of 14.3%, 19.2%, and 25.2% in MAE, RMSE, and MAX, respectively, over the best-performing baseline algorithm (M9). Similar high performance was also achieved on Dataset HSR, confirming the method’s robustness. Furthermore, the method shows excellent scalability, with an estimated computation time of 25.0s for a larger 500-sample dataset, achieving an optimal balance between accuracy and computational efficiency. The optimized Denavit-Hartenberg (D-H) parameters obtained after calibration meet industrial requirements, confirming the method’s superiority and applicability in robot calibration tasks.
31 March 2025 in IEEE Sensors Journal
The void fraction is an important parameter to characterize the characteristics of annular flow, which is an important precondition for calculating the flow velocity, average density, pressure gradient and analyzing the flow status. Based on the principle of convective heat transfer, the effects of the void fraction α and the liquid Froude number Frl on the heat transfer coefficient h of annular flow are analyzed. The thermal distribution sensor of constant power type is designed in this paper. Air-water annular flow experiments have been conducted in a stainless-steel tubular test section having an inside diameter 17.0 mm on the high-precision small-diameter two-phase flow experimental device of Hebei University. The 75 sets of temperature T at four angles (0°, 90°, 180°, 270°) of pipe circumference and entrainment E under different flow conditions were collected. Utilizing the S. L. Smith correlation, the void fraction are calculated. By introducing dimensionless heat transfer coefficient h+, the prediction correlation of void fraction α which could acceptably handle the data is proposed. Laboratory results indicate that the relative error of 99% the data are within ± 3% error band, the mean absolute percentage error (MAPE) of the correlation is 0.63%, and the root mean square error (RMSE) is 0.76%.