We report on the generation of various hole-centered beams in the focal region of a lens and investigate their effectiveness to break the diffraction barrier in fluorescence microscopy by stimulated emission. Patterning of the phase of the stimulating beam across the entrance pupil of the objective lens produces point-spread-functions with twofold, fourfold, and circular symmetry, which narrow down the focal spot to 65–100 nm. Comparison with high-resolution confocal images exhibits a resolution much beyond the diffraction barrier. Particles that are only 65-nm apart are resolved with focused light.
We resolve the classical conflict between parallelization and axial resolution in three-dimensional fluorescence microscopy through time-multiplexed multifocal multiphoton excitation. A rotating array of microlenses on a disk splits ultrafast laser pulses in such a way that an array of high-aperture foci are created in the sample. Two rigidly mounted corotating glass disks with suitable arrays of holes ensure that adjacent foci illuminate the sample at different time points. Recordings of biological specimens demonstrate elimination of out-of-focus haze for densely packed foci and concomitant substantial improvement of contrast and resolution.