Saúl Castro

Saúl Castro

Auto-generated profile, based on publicly available information

Saúl Castro

Dr., Department of Orthodontic, University of Dental Medicine in Oporto, Porto, Portugal

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Journal of Dental Sciences
Verified
Journal Article
Closed access
SCSaúl M. Castro
Saúl M. Castro
MPMaria João Ponces
Maria João Ponces
JLJorge D. Lopes
Jorge D. Lopes
MVMário Vasconcelos
Mário Vasconcelos
MPMaria C.F. Pollmann
Maria C.F. Pollmann

1 January 2015 in The Korean Journal of Orthodontics
Verified
Journal Article
Open access
SCSaúl Matos de Castro
Saúl Matos de Castro
RMRui A.S. Moreira
Rui A.S. Moreira
Ana Cristina BragaAna Cristina Braga
Ana Cristina Braga
AFAfonso Pinhão Ferreira
Afonso Pinhão Ferreira
MPMaria Cristina Pollmann
Maria Cristina Pollmann
To quantify, for each activation, the effect of preactivations of differing distribution and intensity on the neutral position of T-loops (7-mm height), specifically the horizontal force, moment to force (M/F) ratio, and load to deflection ratio. A total 100 loops measuring 0.017 × 0.025 inches in cross-section were divided into two groups (n = 50 each) according to composition, either stainless steel or beta-titanium. The two groups were further divided into five subgroups, 10 loops each, corresponding to the five preactivations tested: preactivations with occlusal distribution (0°, 20°, and 40°), gingival distribution (20°), and occlusal-gingival distribution (40°). The loops were subjected to a total activation of 6-mm with 0.5-mm iterations. Statistical analysis was performed using comprised ANOVA and Bonferoni multiple comparison tests, with a significance level of 5%. The location and intensity of preactivation influenced the force intensity. For the M/F ratio, the highest value achieved without preactivation was lower than the height of the loop. Without preactivation, the M/F ratio increased with activation, while the opposite effect was observed with preactivation. The increase in the M/F ratio was greater when the preactivation distribution was partially or fully gingival. Depending on the preactivation distribution, displacement of uprights is higher or lower than the activation, which is a factor to consider in clinical practice.

13 February 2019
Verified
Book Chapter
Closed access
PDF file
SCS. Castro
S. Castro
MPM.J. Ponces
M.J. Ponces
JLJ.D. Lopes
J.D. Lopes
MVM. Vasconcelos
M. Vasconcelos
JCJ.C. Reis Campos
J.C. Reis Campos
CPC. Pollmann
C. Pollmann
The release of nickel was not necessarily proportional to the alloy’s nickel content. Stainless steel has 8% in his content, however, this biocompatibility may be altered with possible differences in salivary pH and presence of fluoride. The analysis of the corrosion products was carried out for the nickel ion using the spectrophotometers GBC 932 Scientific Equipment PTY, model 932 and Unican, model 939 for each sample as a function of pH (4 and 6,75)/time/ppm fluoride ion (1500 and 22600 ppm). The condition with the longest immersion time at pH 4 was the only one that presented an outcome for the Ni ion above the sensitivity limit of the technique Considering the drawbacks of this in vitro study the results lead to conclude that lowering pH and increasing the immersion time are the most corrosive conditions.

1 January 2012 in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
Verified
Journal Article
Open access
ICIvan Cabo
Ivan Cabo
NSNuno Sampaio Ribeiro dos Santos
Nuno Sampaio Ribeiro dos Santos
SCSaul Castro
Saul Castro
MPMaria João Ponces
Maria João Ponces
JLJorge Dias Lopes
Jorge Dias Lopes

30 November 2018 in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
Verified
Journal Article
Closed access
SCSaúl Castro
Saúl Castro
PVPaula Vaz
Paula Vaz
MPMaria Ponces
Maria Ponces
Introdução: O perfil facial tegumentar em pacientes tratados ortodonticamente tem sido estudado com o objetivo de encontrar a harmonia no relacionamento com ...

14 November 2017
Verified
Book Chapter
Closed access
PDF file
SCSaúl Castro
Saúl Castro
RMRamiro Martins
Ramiro Martins
RCReis Campos
Reis Campos
PTPaulo Teles
Paulo Teles
MPMaria Pollmann
Maria Pollmann
Due to its ionic, thermal, microbiological and enzymatic properties, the oral environment is propitious to the biodegradation of metallic wires. The roughness and the arches surface is strongly related with its corrosion. F. Widu et al. demonstrates that the surface roughness can be an indicator of the corrosive tendency of the orthodontic wires. Corrosion of orthodontic wires influences its physical properties and consequent clinical performance. The difference in the roughness value of the T-loops is lower for an immersion period of 5 months than the values for immersion periods of 1 and 3 months. In accordance with the estimated model, the difference between the initial and final values of roughness after 5 months of immersion in saliva is 0.012 µm higher than the difference between the initial and final values of roughness after 1 and 3 months of immersion in saliva. Measurements were preformed applying a M1 filter and in accordance with ISO 11562.