To quantify, for each activation, the effect of preactivations of differing distribution and intensity on the neutral position of T-loops (7-mm height), specifically the horizontal force, moment to force (M/F) ratio, and load to deflection ratio. A total 100 loops measuring 0.017 × 0.025 inches in cross-section were divided into two groups (n = 50 each) according to composition, either stainless steel or beta-titanium. The two groups were further divided into five subgroups, 10 loops each, corresponding to the five preactivations tested: preactivations with occlusal distribution (0°, 20°, and 40°), gingival distribution (20°), and occlusal-gingival distribution (40°). The loops were subjected to a total activation of 6-mm with 0.5-mm iterations. Statistical analysis was performed using comprised ANOVA and Bonferoni multiple comparison tests, with a significance level of 5%. The location and intensity of preactivation influenced the force intensity. For the M/F ratio, the highest value achieved without preactivation was lower than the height of the loop. Without preactivation, the M/F ratio increased with activation, while the opposite effect was observed with preactivation. The increase in the M/F ratio was greater when the preactivation distribution was partially or fully gingival. Depending on the preactivation distribution, displacement of uprights is higher or lower than the activation, which is a factor to consider in clinical practice.
The release of nickel was not necessarily proportional to the alloy’s nickel content. Stainless steel has 8% in his content, however, this biocompatibility may be altered with possible differences in salivary pH and presence of fluoride. The analysis of the corrosion products was carried out for the nickel ion using the spectrophotometers GBC 932 Scientific Equipment PTY, model 932 and Unican, model 939 for each sample as a function of pH (4 and 6,75)/time/ppm fluoride ion (1500 and 22600 ppm). The condition with the longest immersion time at pH 4 was the only one that presented an outcome for the Ni ion above the sensitivity limit of the technique Considering the drawbacks of this in vitro study the results lead to conclude that lowering pH and increasing the immersion time are the most corrosive conditions.
1 January 2012 in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
Introdução: O perfil facial tegumentar em pacientes tratados ortodonticamente tem sido estudado com o objetivo de encontrar a harmonia no relacionamento com ...
Due to its ionic, thermal, microbiological and enzymatic properties, the oral environment is propitious to the biodegradation of metallic wires. The roughness and the arches surface is strongly related with its corrosion. F. Widu et al. demonstrates that the surface roughness can be an indicator of the corrosive tendency of the orthodontic wires. Corrosion of orthodontic wires influences its physical properties and consequent clinical performance. The difference in the roughness value of the T-loops is lower for an immersion period of 5 months than the values for immersion periods of 1 and 3 months. In accordance with the estimated model, the difference between the initial and final values of roughness after 5 months of immersion in saliva is 0.012 µm higher than the difference between the initial and final values of roughness after 1 and 3 months of immersion in saliva. Measurements were preformed applying a M1 filter and in accordance with ISO 11562.