Sebastian Kibler

Sebastian Kibler

Auto-generated profile, based on publicly available information

Sebastian Kibler

Fraunhofer Institute for Electronic Microsystems and Solid-State Technologies EMFT, Hansastrasse 27d, 80686 Munich, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
ABAgnes Bußmann
Agnes Bußmann
CDClaudia Durasiewicz
Claudia Durasiewicz
SKSebastian Heinrich Alexander Kibler
Sebastian Heinrich Alexander Kibler
CWChristian Klaus Wald
Christian Klaus Wald

3 April 2017 in Sensors
Verified
Journal Article
Open access
PDF file
CJChristoph Jenke
Christoph Jenke
JRJaume Pallejà Rubio
Jaume Pallejà Rubio
SKSebastian Kibler
Sebastian Kibler
JHJohannes Häfner
Johannes Häfner
MRMartin Richter
Martin Richter
CKChristoph Kutter
Christoph Kutter
With the combination of micropumps and flow sensors, highly accurate and secure closed-loop controlled micro dosing systems for liquids are possible. Implementing a single stroke based control mode with piezoelectrically driven micro diaphragm pumps can provide a solution for dosing of volumes down to nanoliters or variable average flow rates in the range of nL/min to μL/min. However, sensor technologies feature a yet undetermined accuracy for measuring highly pulsatile micropump flow. Two miniaturizable in-line sensor types providing electrical readout—differential pressure based flow sensors and thermal calorimetric flow sensors—are evaluated for their suitability of combining them with mircopumps. Single stroke based calibration of the sensors was carried out with a new method, comparing displacement volumes and sensor flow volumes. Limitations of accuracy and performance for single stroke based flow control are described. Results showed that besides particle robustness of sensors, controlling resistive and capacitive damping are key aspects for setting up reproducible and reliable liquid dosing systems. Depending on the required average flow or defined volume, dosing systems with an accuracy of better than 5% for the differential pressure based sensor and better than 6.5% for the thermal calorimeter were achieved.

8 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TTThomas Alexander Thalhofer
Thomas Alexander Thalhofer
MKMauro Keck
Mauro Keck
SKSebastian Kibler
Sebastian Kibler
OHOliver Hayden
Oliver Hayden
Microfluidic systems are of paramount importance in various fields such as medicine, biology, and pharmacy. Despite the plethora of methods, accurate dosing and mixing of small doses of liquid reagents remain challenges for microfluidics. In this paper, we present a microfluidic device that uses two micro pumps and an alternating drive pattern to fill a microchannel. With a capacitive sensor system, we monitored the fluid process and controlled the micro pumps. In a first experiment, the system was set up to generate a 1:1 mixture between two fluids while using a range of fluid packet sizes from 0.25 to 2 µL and pumping frequencies from 50 to 100 Hz. In this parameter range, a dosing accuracy of 50.3 ± 0.9% was reached, validated by a gravimetric measurement. Other biased mixing ratios were tested as well and showed a deviation of 0.3 ± 0.3% from the targeted mixing ratio. In a second experiment, Trypan blue was used to study the mixing behavior of the system. Within one to two dosed packet sets, the two reagents were reliably mixed. The results are encouraging for future use of micro pumps and capacitive sensing in demanding microfluidic applications.

15 January 2024 in Journal of Pharmaceutical Sciences
Verified
Journal Article
Open access
DPDavid Plano
David Plano
SKSebastian Kibler
Sebastian Kibler
NRNiklas Rudolph
Niklas Rudolph
OZOliver Zett
Oliver Zett
JDJennifer Dressman
Jennifer Dressman
Drug release plays a crucial role in drug delivery. While current formulation approaches are capable of coarse-tuning the release profile, their precision and reproducibility are limited by the physicochemical properties of the excipients and active pharmaceutical ingredient (API). Innovative and advanced approaches are urgently needed, especially for site-specific targeting of drugs and to address their pharmacological requirements for optimal therapy. The 5 × 5 × 0.6 mm3 piezoelectric micropump developed by Fraunhofer EMFT was designed to enable precise drug delivery in a low volume format. In this study, we investigated the ability of the micropump to deliver solutions of highly soluble APIs using a wide range of customized pump profiles. Additionally, we examined the ability of the micropump to deliver suspensions containing various defined particle sizes. While results for suspensions indicate that pumping performance is highly dependent on the size and concentration of the suspended particles, results with API solutions demonstrate high precision and reproducibility of release, coupled with maximum flexibility in the release profile of the API. The piezoelectric micropump thus lays the cornerstone in the development of a wide range of innovative drug delivery profiles, enabling customized release profiles to be programmed and thus paving the way to fully personalized medicine.